CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certified kit is used.
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property
damage, personal injury or loss of life. Refer to this manual. Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Model Number FV200 - FV200P
Free Standing Vented Gas Stove
Stock #'s: FV200N, FV200LP, FV200PN, FV200PLP are
Certified to: ANZI Z21.88-2009, CSA 2.33-2009
Listed Vented Gas Fired Free Standing Room Heater
INSTALLER: Leave this manual with the appliance.

FOR YOUR SAFETY

What to Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
Printed in Canada October 19, 2009 200V-MAN
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FV200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingsman FV200

  • Page 1: For Your Safety

    Installation Instructions Model Number FV200 - FV200P Free Standing Vented Gas Stove Stock #’s: FV200N, FV200LP, FV200PN, FV200PLP are Certified to: ANZI Z21.88-2009, CSA 2.33-2009 Listed Vented Gas Fired Free Standing Room Heater INSTALLER: Leave this manual with the appliance.
  • Page 2: Installation Questions And Answers

    PRE-INSTALLATION QUESTIONS and ANSWERS Why does my fireplace or stove give off odour? It is normal for your fireplace to give off some odour. This is due to the curing of the paint, adhesives, silicones and any undetected oil from the manufacturing process as well as the finishing materials used with the installations (e.g.
  • Page 3: Table Of Contents

    Table of Contents Installation Questions and Answers ....2 Warnings, Installation and Operations ....4 Operations and Maintenance Instructions .
  • Page 4: Warnings, Installation And Operations

    Warnings, Installations, and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States.
  • Page 5: Operations And Maintenance Instructions

    • Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source. • This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 6: Installation And Operation

    INSTALLATION AND OPERATION FV200 FV200P Leg Model Pedestal ⁄ ” ⁄ ” ⁄ ” ⁄ ” ⁄ ” ⁄ ” 15” 15” 4” Dia 4” Dia. ⁄ ” ⁄ ” NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 7: Gas Line Installation

    GAS LINE INSTALLATION This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 installation codes for Gas Burning Appliances and Equipment in Canada and the National Fuel Gas Code Z223.1 in the United States. NOTE: IF THE OPTIONAL FAN KIT IS TO BE INSTALLED IT IS HIGHLY RECOMMENDED THAT IT BE ATTACHED TO THE STOVE BEFORE THE STOVE IS PUT IN ITS FINAL POSITION.
  • Page 8: Gas Specifications

    FV200 - FV200P NG/LP GAS SPECIFICATIONS FUEL MAXIMUM INPUT CONTROL (BTU) FE P.4.1-02 STEADY HIGH (CDN) STATE NATURAL GAS MILLIVOLT 30,000 20,000 68.3% PROPANE GAS MILLIVOLT 32,000 25,000 68.7% GAS INLET SIZE 3/8”(SIT) # 37 1/2” # 51 FULL OPEN...
  • Page 9: General Glass Information

    The venting system (chimney) of this appliance should be inspected at least once a year and if needed, your venting system should be cleaned. Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapours and liquids.
  • Page 10: Installation Of Brick Panel Kit

    Warning and Cautions. • Do not clean when the glass is hot. • Do not use abrasive cleaners. • Using a substitute glass will void all product warranties. • Do not strike or abuse glass. Care must be taken to avoid breakage of the glass. •...
  • Page 11: Log Assembly

    Installation Instructions for LOGC200 Remove can of touchup paint from firebox ❺ ❹ Notch WARNING: ❷ Failure to ❸ position the parts in ❻ ❶ Notch accordance with these diagrams 2nd Grate Bar or failure to use Notch Notch only parts Locating Tabs Log and Ember Chunk Kit specifically...
  • Page 12: Optional Fan Kit Installation

    OPTIONAL FAN KIT INSTALLATION Note: Leg model shown, use the same mounting procedures for pedestal models. PARTS LIST: - Mounting bracket (4000-5000 only) - 1 Variable speed control with 2 male ends - 1 black knob - 1 speed nut - 2 fan mounting screws NOTE: THE FAN ADAPTER IS NOT USED ON 200 MODEL UNITS.
  • Page 13: Millivolt System, Lighting, & Burner Control

    MILLIVOLT SYSTEM, LIGHTING, & BURNING CONTROL WARNIING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 14 MILLIVOLT SYSTEM, LIGHTING, & BURNING CONTROL CONT. SPILL SAFETY SWITCH - Wiring Diagram 820-639 and 820-640 True Millivolt Systems This System does not have a thermocouple PILOT BURNER ADJUSTMENT Locate pilot adjustment (up and to the right approximately 1/2" from Hi/Lo control). 2.
  • Page 15: Vent Installation

    VENT INSTALLATION VENTING INSTRUCTIONS NOTE: A chimney venting this stove shall not vent any other appliance. This appliance may be vented in various types of applications, 'A' Vent of solid fuel wood burning chimney. Masonry Clay lining and 'B' Vent liquid fuel gas chimney.
  • Page 16: Replacement Parts List

    PARTS LIST Product Number Description FV200N Free Standing B - Vent Leg Stove - Natural Gas - Painted Black FV200LP Free Standing B - Vent Leg Stove - Liquid Propane - Painted Black FV200PN Free Standing B - Vent Pedestal Stove - Natural Gas - Painted Black FV200PLP Free Standing B - Vent Pedestal Stove - Liquid Propane - Painted Black LOG SET: (REQUIRED FOR EACH UNIT)
  • Page 17: Conversion Kit Instructions

    CONVERSION KIT INSTRUCTIONS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. WARNIING: This conversion kit shall be installed by a qualified service agency accordance...
  • Page 18: Gas Conversion Kit For Top Convertible Pilot

    GAS CONVERSION KIT FOR TOP CONVERTIBLE PILOT SERIES 019065X Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG Only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 19: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 20: Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.