Kingsman FDV451 Installation Instructions Manual

Kingsman FDV451 Installation Instructions Manual

Free standing direct vent gas stove
Hide thumbs Also See for FDV451:
Table of Contents

Advertisement

Installation Instructions

Model Number FDV451 & MQFDV453
Free Standing Direct Vent Gas Stove
Stock #'s: FDV451N, FDV451NE, FDV451LP, FDV451LPE,
MQFDV453N, MQFDV453NE, MQFDV453LP, MQFDV453LPE are
Certified to: ANSI Z21.88-2014 • CSA 2.33-2014
This appliance may be installed in an
aftermarket permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local
codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases, unless a certified kit is
used.
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for future
reference.
VANTGE
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
Printed in Canada October 19, 2015
Part # 451-MAN-14
MQFDV453

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FDV451 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingsman FDV451

  • Page 1: Installation Instructions

    Installation Instructions Model Number FDV451 & MQFDV453 Free Standing Direct Vent Gas Stove Stock #’s: FDV451N, FDV451NE, FDV451LP, FDV451LPE, MQFDV453N, MQFDV453NE, MQFDV453LP, MQFDV453LPE are Certified to: ANSI Z21.88-2014 • CSA 2.33-2014 This appliance may be installed in an aftermarket permanently located,...
  • Page 2: Table Of Contents

    Fan Installation……………………………………………………………………………………………………………………. Split Receptacle- Switch Control Outside of Fireplace……………………………………………………………..………… Door and Glass Information………………………………………………………………………………………………..…..FDV451 / MQFDV453 Glass Front Door Removal / Installation……………………………………………………………. MQ453 Glass Side Door Removal / Installation………………………………………………………………………………. Important Information For Door Fronts, Vent Lids, And Side Doors………………………………………………………… F450F Front Door Kit -Door Face with Safety Screen and Vent Lid.……………………………………………………….
  • Page 3 Venting Routes And Components……………………………………………………………………………………………… Venting Table…………………………………………………………………………………………………......Horizontal Vent Installation……………………………………………………………………………………………………… Z47ST24 / Z47ST36 Horizontal Snorkel Terminations………………………………………………………………………. Vertical Venting above 12 Feet…………………………………………………………………………………………………. Vertical Vent Installation…………………………………………………………………………………………………………. 55-56 Troubleshooting the Gas Control System……………………………………………………………………………………… PARTS LISTS FDV451 / MQFDV453 Parts List………………………………………………………………………………………………... 58-60 WARRANTY Limited Lifetime Warranty………………………………………………………………………………………………..…..
  • Page 4: Glass Safety / Termination Cap Safety- All Units

    -Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Any safety screen, guard, or barrier removed for servicing the appliance, must be replaced prior to operating the appliance.
  • Page 5: Warnings, Installations And Operations

    Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the National Electrical Code;...
  • Page 6: Operations And Maintenance Instructions

     Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source.  This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 7: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 8: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 9: Locating Your Appliance / Fireplace Dimensions

    FRONT RIGHT SIDE (MQFDV453 Shown) FDV451 / MQFDV453 Locating Your Appliance / Clearance To Combustibles The unit should be placed on a hard, stable surface. The appliance may be installed directly on carpeting, tile or other combustible material with no additional floor protection being required.
  • Page 10: Gas Line Installation

    1/2 PSIG (3.5 KPa). NOTE: The gas line connection may be made of 1/2” rigid pipe or an Approved Kingsman Flex Connector, such as FP15GC.
  • Page 11: Fan Installation

    Fan Installation F450FK FDV451 / MQFDV453 ⚠ WARNING Electrical Grounding Instructions This appliance is equipped with a three prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this.
  • Page 12: Split Receptacle- Switch Control Outside Of Fireplace

    Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
  • Page 13: Door And Glass Information

     Do not strike or abuse the glass. Glass Replacement Only Robax ceramic or coated Neoceram glass may be used for replacement for all FDV451 / MQFDV453 Models. Glass must be minimum 5mm thick. To replace glass, clean all materials from the door frame. Scrape off old silicone all the way down to the metal. Using high-temp silicone [rated up to 500°F (260°C)] apply a continuous bead of approximately 1/8”-3/16”...
  • Page 14: Fdv451 / Mqfdv453 Glass Front Door Removal / Installation

    FDV451 / MQFDV453 Glass Front Door Removal / Installation To Remove Door: Using supplied latch tool, pull top latches forward and up to release from door. Swing door down and pull away from appliance to release. To Install Door: Engage door in lower latches at an angle of between 5 and 10 degrees below horizontal.
  • Page 15: Mq453 Glass Side Door Removal / Installation

    MQFDV453 Glass Side Door Removal / Installation ⚠WARNING: Wait until unit is COMPLETELY cool before touching glass or attempting to install or remove Glass Door. To Remove Door: Remove [4] KEPS nuts with a 7/16” wrench. NOTE: Do not overtighten nuts, as gasket or glass may be damaged To Replace Door: Place Glass Side Door over studs.
  • Page 16: Important Information For Door Fronts, Vent Lids, And Side Doors

    ⚠ IMPORTANT INFORMATION FOR DOOR FRONTS, VENT LIDS, AND SIDE DOORS WARNING: SIDE DOOR PANEL GETS EXTREMELY HOT! DO NOT OPEN SIDE DOOR PANEL UNTIL UNIT IS COMPLETELY COOL. INSTALLATION NOTES:  Cotton gloves must be worn to protect the finish during installation and handling. ...
  • Page 17: F450F Front Door Kit -Door Face With Safety Screen And Vent Lid

    FDV451 / MQFDV453 -F450F Door Front Kit- Kit contains: [1] Door Face with safety screen, [2] DT Screws, [1] Vent Lid. ⚠WARNING: Wait until unit is COMPLETELY cool before touching glass or attempting to install or remove Front Face. MOUNT HOLE...
  • Page 18: Vent Lid Installation

    FDV451 / FDV453 Vent Lid Installation VENT LID MUST BE IN PLACE BEFORE VENTING IS CONNECTED. Notch Mount Tab To install Vent Lid:  Place Vent Lid onto fireplace and center over flue.  Mount Tabs will engage with notches inside recess on appliance top.
  • Page 19: F451Sd / Mq453Sd Side Door Kits

    F451SD / MQ453SD -Side Door Kits- Kit contains: [1] Pair of Side Door Panels with safety screens, [4] DT Screws. ⚠ WARNING: Wait until unit is COMPLETELY cool before touching glass or attempting to install or remove Side Panel. SAFETY SCREEN BARRIER HINGES HINGE MOUNT LOCATIONS MAGNETS...
  • Page 20: F451Pl / F453Pl Porcelain Liner Installation

    F451PL / F453PL – Porcelain Liner Installation / Removal ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. F451PL: [1] Back Liner, [2] Side Liners F453PL: [1] Back Liner only ________________________________________...
  • Page 21: F451Rl / F453Rl Brick Liner Installation

    F451RL / F453RL – Brick Liner Installation / Removal ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. F451RL: [1] Back Liner, [2] Side Liners F453RL: [1] Back Liner only GRATE...
  • Page 22: 51Uhs Box / Component Locations

    FDV451 / MQFDV453 51UHS Box INCLUDED WITH BASE MODEL (MILLIVOLT) UNITS. The 51-UHS Box is designed for millivolt and IPI units for in-unit installation of the Remote Receiver, Fan Control Module, and the IPI Module. 51-UHS Box can be inserted & removed from beneath fireplace through Side panel opening.
  • Page 23: F45Lg Log Grate Installation

    F45LG Log Grate Installation FDV451 / MQFDV453 Contents of Kit: [1] Horizontal Grate Bar with Andiron, [1] Andiron Step 1: Slide loose Andiron onto Grate Bar. Step 2: Insert Andirons into slots in False Bottom. SLOTS...
  • Page 24: Logf451 Oak Log Set

    LOGF451 – Oak Log Set ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. NOTE: Lava Rock, 350 Embers, and Vermiculite are packaged with fireplace. Can be used with Optional F45LG Grate Bar.
  • Page 25: Logf451 Oak Logset

    3: Place LOG 3 and LOG 4 as shown below. 4: Place LOG 5 and LOG 6 as shown below. LOG 4 LOG 3 LOG 6 LOG 5 5: Place 350 Embers and Vermiculite in areas shown below. LOGF451 Oak Logset LOGF451 Oak Logset with optional F45LG Grate Bar.
  • Page 26: Logf452 Oak Log Set

    MQLOGF452 – Oak Log Set ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. NOTE: Lava Rock, 350 Embers, and Vermiculite are supplied with fireplace. Can be used with Optional F45LG Grate Bar.
  • Page 27: Logf452 Oak Log Set

    3: Place LOG 4 and LOG 5 as shown below. 4: Place LOG 6 and LOG 7 as shown below. LOG 5 LOG 4 LOG 7 LOG 6 5: Place LOG 2 and LOG 3 as shown below. 6: Place 350 Embers and Vermiculite in areas shown below.
  • Page 28: Mq453Log Driftwood Log Set

    MQLOGF453 – Driftwood Log Set ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. NOTE: Lava Rock and 350 Embers supplied with fireplace. Can be used with Optional F45LG Grate Bar.
  • Page 29 3: Place LOG 3 as shown below. 4: Place LOG 4 behind LOG 2 on the right side. LOG 4 LOG 2 LOG 3 5: Place LOG 5 as shown below. 6: Place 350 Embers and Vermiculite in areas shown below.
  • Page 30: Rbcb1 Cannonballs

    RBCB1 -Cannonballs- Installation Instructions FDV451 / MQFDV453 Assorted size and colors. Place randomly as desired inside fireplace. -MUST BE USED WITH 15LBS OF GLASS MEDIA- Can be used with MQ Glass, MQ Ember, and / or Lava Rock. Do not place Cannonballs directly on burner ports.
  • Page 31: Mq Dealer Accessories

    MQ Dealer Accessories for FDV451 / MQFDV453 The following Accessories are available through MQ Dealers only.  GLASS (MQG5W, MQG5C, MQG5A, MQG5B, MQG5ZG) ACCESSORY ITEM DESCRIPTION If you wish to use this media evenly spread the glass embers onto the false bottom and burner.
  • Page 32: Mq Stone Decorative Stone Set

    MQ Stone Decorative Stone Set MQ Stone can be placed on or around Burner. Lava Rock (Supplied with Base MQ EMBER (shown) can be placed on Burner. Unit). Do not place on Burner. MQ Glass can be placed on Burner and Glass Tray. ...
  • Page 33: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING  This appliance has a pilot which must be lighted by hand. When Immediately call your gas supplier from a neighbour’s phone.
  • Page 34: Burner System Maintenance

    Burner System Maintenance FDV451 / MQFDV453 It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 35: Restrictor Baffle Setting For Gas Conversions

    Restrictor Baffle Setting for Gas Conversions FDV451 / MQFDV453 The Restrictor Baffle must be set correctly in order for the appliance to function properly. NG Setting Tabs flat Restrictor Baffle Located in top of firebox at the front. LP Setting Tabs bent down 90°...
  • Page 36: Gas Conversion- Part A

    FDV451 / MQFDV453 Gas Conversion Part A Models: FDV451N, FDV451NE, FDV451LP, FDV451LPE, MQFDV453N, MQFDV453NE, MQFDV453LP, MQFDV453LPE Description Pilot Orifice Burner Orifice Brass Nipple Air Shutter Hi/Lo Regulator Kit Number Brass (1000-255) 450DV-CKLP LP Conversion 1001-P167SI 1000-253 Fully Open 1001-P202SI #30 (977.167)
  • Page 37: Gas Conversion Kit For Top Convertible Pilot- Part B

    Gas Conversion for Top Convertible Pilot – Part B (series 0190XYZ) Instructions for converting SIT 190 series pilot burner injector from NG to LPG and from LPG to NG only. This information should be considered as supplemental to the Appliance Manufacturer's Instructions. WARNING! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 38: Gas Conversion For Modulator- Part C

    Gas Conversion for Modulator – PART C...
  • Page 39: Burner Removal

    FDV451 / MQFDV453 Burner Removal 1. Remove [2] DT Screws behind Grate and lift False Bottom 2. Loosen Burner Hold Downs. Assembly out of firebox. 3. Slide H Burner to the left. 4. Remove Burner. 5. To remove entire Burner Pan, remove [16] DT Screws around perimeter of pan.
  • Page 40: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview Cover The IPI system is an advanced burner controller that provides you with the option of having either a Standing- Pilot, or an intermittent igniting system. This alternating Backup mode is controlled by the CPI/IPI Switch (Continuous Pilot Battery Ignition/Intermittent Pilot Ignition) located on the IPI System Pack...
  • Page 41: Remote Control Operation

    -Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart thermostatic control of the appliance. Transmitter Remote Receiver Transmitter Room Thermostat ( Transmitter Operation) The Transmitter is powered by 3 AAA type batteries. A Mode The Remote Control can operate as a room thermostat.
  • Page 42: Ipi Electronic Ignition Parts List - Standard System

    IPI Electronic Ignition Parts List – Standard System ITEM NO. PART NO. DESCRIPTION 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/Lo LP *1002-P047si Pilot Assembly-LP -24” Wire *1002-P033si Pilot Assembly-NG -24” Wire 1002-P017si Spark Electrode (with wire) *1002-P119si Spark Electrode (with wire- 35” Length) 1002-P903si Electrode Flame Sensor *1002-P910si...
  • Page 43: Configuration 1: Basic Manual Hi / Lo And Manual Off

    Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 44: Configuration 2: Remote On / Off And Manual Hi / Lo

    Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 45: Operating The Receiver Without Batteries For Gt / Egt / Gtm / Egtm Remote Controls

    Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivolt systems. -Millivolt Systems will also require Power Adapter P/N 1002-P850si. The Remote Receiver & IPI or Millivolt system can be powered by the AC Adapter. This is advantageous if you do not want to use batteries.
  • Page 46: Configuration 3: Remote On/Off, Variable Hi/Lo, And Fan

    Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan installation.
  • Page 47: Electronic Ignition Lighting Instructions

    Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING: A.
  • Page 48: Vent Termination

    Vent Termination WARNING: WHEN THE HORIZONTAL VENT TERMINATION IS ACCESSIBLE A CERTIFIED GUARD (SAFETY CAGE) SHALL Notes: BE INSTALLED. 1) Clearances are to the edge of the terminal plate. Add 6-3/4” to clearances to arrive at centerline. 2) Local codes or regulations may require different clearances.
  • Page 49: General Venting Information

    FDV451 / MQFDV453 General Venting Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex (Z-Flex) Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use Simpson-Duravent Direct Vent system (Model DV-GS Series), BDM Pro Form Direct Vent, Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
  • Page 50: Venting Routes And Components

    FDV451 / MQFDV453 Venting Routes and Components Since it is very important that the vent system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be adhered to.
  • Page 51: Venting Table

    FDV451 / MQFDV453 Venting Table IMPORTANT: ALWAYS LOCATE THE STOVE IN SUCH A WAY AS TO MINIMIZE THE NUMBER OF OFFSETS AND/OR HORIZONTAL RUNS. A 1/4” VERTICAL RISE IS REQUIRED FOR EVERY 12” OF HORIZONTAL RUN. The following table shows the relationship between vertical and horizontal vent lengths and will help you to determine the correct vent lengths for optimum stove performance.
  • Page 52: Horizontal Vent Installation

    FDV451 / MQFDV453 Horizontal Vent Installation Silicone and Screw Wall Thimble or Clamp Decorative Cover 1” top of horizontal vent 1” minimum 2” top of 90° elbow Trim Ring Caulk Silicone and Screw All other existing pipes 1” clearance. (Both Sides)
  • Page 53: Z47St24 / Z47St36 Horizontal Snorkel Terminations

    Z47ST24 / Z47ST36 Horizontal Snorkel Terminations Two snorkel terminations are available if a vertical rise is necessary on the exterior side of a building: Z47ST24 (24” Tall, 14-1/2” Center to Center) Z47ST36 (36” Tall, 26-1/2” Center to Center) Follow standard horizontal venting installation procedures. If the Snorkel Termination is to be located below grade, a codes.
  • Page 54: Vertical Venting Above 12 Feet

    Vertical Venting above 12 Feet FDV451 MQFDV453 Air Restrictor When vertical venting will be 12 feet or higher, use the Air Restrictor provided. To use Air Restrictor, simply insert behind False Bottom as shown.
  • Page 55: Vertical Vent Installation

    FDV451 / MQFDV453 Vertical Vent Installation Framing Detail Attic Insulation Shield Fire Stop Using Flex Bends Use roof support and rigid pipe at roof level. Flex pipe is not permitted within roof support. When penetrating the roof a rigid galvanized pipe must be used. Attach flex pipe to the rigid pipe with high temperature sealant, secure with four screws assuring the flex pipe and rigid pipe are secured.
  • Page 56 FDV451 / MQFDV453 Vertical Vent Installation FDVVSK: Vertical Vent Starter Kit 12” Rule Starter Kit contains: Attic Insulation Shield, Decorative Ceiling Trim Ring, Level Black Band, brass Band, Roof Support, Spacer Springs (6), Mill Pac. 3” Roof FDVVT40 Termination This would be a 3/12 Pitch...
  • Page 57: Troubleshooting The Gas Control System

    Troubleshooting the Gas Control System WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not light. Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is electrode at pilot.
  • Page 58: Fdv451 / Mqfdv453 Parts List

    FDV451 / MQFDV453 Parts List (Thermostat/Modulating - LP) -FDV451 KINGSMAN STOVE- Remote Control IPI EGTFRCN VANTAGE FREE STANDING DIRECT VENT GAS (Thermostat/Modulating/Fan - NG) STOVE Remote Control IPI EGTFRCP Listed for USA/Canada as a Vented Gas Fireplace Heater, (Thermostat/Modulating/Fan - LP) Dual Burner, Ceramic Glass, Glowing Embers, Hi/Lo SIT Valve, On/Off Switch, 4/7”...
  • Page 59 Remote Control Millivolt – GTFRCP -MQFDV453 MARQUIS STOVE- Thermostat/Modulating/Fan – LP VANTAGE FREE STANDING DIRECT VENT GAS Remote Control IPI (Thermostat) EGTRC STOVE – BAY VIEW Remote Control IPI EGTMRCN Listed for USA/Canada as a Vented Gas Fireplace Heater, (Thermostat/Modulating - NG) Dual Burner, Ceramic Glass, Glowing Embers, Hi/Lo SIT Remote Control IPI Valve, On/Off Switch, 4/7”...
  • Page 60 FP15GC Stainless Steel Gas Connector 450FDV-300 Front Glass 453FDV-309 Side Glass KINGSMAN FIREPLACE VENTING Horizontal Vent Starter Kit - (Direct Vent FDVHSK Stoves) Starter Kit Contains: Horizontal Vent Termination, Zero Clearance Wall Sleeve, Black Wall Trim Ring, 7" Dia. Black Pipe 24" Length, 7" Dia. Black Pipe 48"Length 7"...
  • Page 61: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

This manual is also suitable for:

Mqfdv453

Table of Contents