Kingsman FDV350 Installation Instructions Manual

Free standing direct vent gas stove (field convertible to vented stove)
Hide thumbs Also See for FDV350:

Advertisement

Installation Instructions

Free Standing Direct Vent Gas Stove
(Field Convertible to Vented Stove)
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certified kit is used.
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property
damage, personal injury or loss of life. Refer to this manual. Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
For Propane Horizontal installations the venting must be a minimum of one foot vertical off the
flue before going horizontal.
Model Number FDV350
Stock #'s: FDV350N, FDV350LP are
Certified to: ANZI Z21.88-2009, CSA 2.33-2009
Listed Direct Vent Gas Fired Free Standing Room Heater
INSTALLER: Leave this manual with the appliance.

FOR YOUR SAFETY

What to Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
Printed in Canada January 19, 2010 350-MAN
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FDV350 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kingsman FDV350

  • Page 1: Installation Instructions

    Installation Instructions Model Number FDV350 Free Standing Direct Vent Gas Stove (Field Convertible to Vented Stove) Stock #’s: FDV350N, FDV350LP are Certified to: ANZI Z21.88-2009, CSA 2.33-2009 Listed Direct Vent Gas Fired Free Standing Room Heater INSTALLER: Leave this manual with the appliance.
  • Page 2 PRE-INSTALLATION QUESTIONS and ANSWERS Why does my fireplace or stove give off odour? It is normal for your fireplace to give off some odour. This is due to the curing of the paint, adhesives, silicones and any undetected oil from the manufacturing process as well as the finishing materials used with the installations (e.g.
  • Page 3: Table Of Contents

    Vertical vent installation ........21 Converting the FDV350 Direct Vent to a vented fireplace ... .22 B-Vent converter instructions .
  • Page 4: Mobile Home/Manufactured Housing Installation

    MOBILE HOME/MANUFACTURED HOUSING INSTALLATION This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NCBS A225.1, and with CSA Z240.4 Mobile Home Standard in Canada.
  • Page 5: Warnings, Installations And Operations

    Warnings, Installations, and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States.
  • Page 6: Operation Maintenace And Instructions

    • Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source. • This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 7: Dimensions

    DIMENSIONS Gas inlet is located on the back of the unit. LOCATING YOUR APPLIANCE THE FOLLOWING MINIMUM DISTANCES TO COMBUSTIBLES MUST BE OBSERVED TO ENSURE SAFE OPERATION OF YOUR STOVE. 1” clearance to combustibles on vertical venting The unit should be placed on a hard, stable surface. The appliance may be installed directly on carpeting, tile or other combustible material with no additional floor protection being required.
  • Page 8: Gas Line Installation

    GAS LINE INSTALLATION This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN\CGA-B149.1 or .2 installation codes for Gas Burning Appliances and Equipment in Canada and the National Fuel Gas Code Z223.1 in the United States. NOTE: IF THE OPTIONAL FAN KIT IS TO BE INSTALLED IT IS HIGHLY RECOMMENDED THAT IT BE ATTACHED TO THE STOVE BEFORE THE STOVE IS PUT IN ITS FINAL POSITION.
  • Page 9: Gas Specifications

    GAS SPECIFICATIONS FUEL MAXIMUM INPUT MAXIMUM OUTPUT CONTROL (BTU) (BTU) HIGH HIGH NATURAL GAS MILLIVOLT 37,000 29,000 28,860 PROPANE GAS MILLIVOLT 35,000 27,000 27,650 GAS INLET SIZE 3/8”(SIT) # 32 5/16” # 50 FULL OPEN OPERATING AND MAINTENANCE INSTRUCTIONS This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA-B149.1 or .2 installation codes for Gas Burning Appliances and Equipment.
  • Page 10: Operating And Maintenance Instructions

    OPERATING AND MAINTENANCE INSTRUCTIONS This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA-B149.1 or .2 installation codes for Gas Burning Appliances and Equipment. WARNING: WHEN PURGING THE GAS LINE, THE GLASS FRONT MUST BE REMOVED. FOR SAFE INSTALLATION AND OPERATION NOTE THE FOLLOWING: This appliance gives off high temperatures and should be located out of heavy traffic areas and away from furniture and draperies.
  • Page 11: General Glass Information

    GENERAL GLASS INFORMATION GLASS CLEANING It will be necessary to clean the glass periodically. During Warning and Cautions. start-up, condensation, which is normal, forms on the • Do not clean when the glass is hot. inside of the glass and causes dust, lint etc. to cling to the •...
  • Page 12: Installation Of Brick Panel Kit

    INSTALLATION OF BRICK PANEL KIT PART: F35RL 1. Open side panels and remove front door and log set. (Skip this step if components are not installed at this time.) 2. The rear log holder has to be removed to install rear brick panel, using a 1/4” nut driver remove the three hex screws.
  • Page 13: Log Assembly

    F35 LOG ASSEMBLY WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Fig. 1. Remove can of touchup paint from firebox. Remove logs and bag of glowing embers chunks from carton and inspect. There are three logs and they are lettered A, B, and C.
  • Page 14: Optional Fan Kit Installation

    OPTIONAL FAN KIT INSTALLATION NOTE: FOR EASE OF INSTALLATION THE FAN KIT SHOULD BE INSTALLED BEFORE THE STOVE IS PUT IN ITS FINAL POSITION. AUTOMATIC ON/OFF THERMOSTAT CONTROLLED FAN KIT (Part #F35FK) 1. Open the front access door where the piezo-igniter is located. Remove the two screws that hold the control panel in place, pull the control panel out towards you and install the variable speed control in the hole provided opposite the piezo-igniter.
  • Page 15: Millivolt System, Lighting, & Burner Control

    MILLIVOLT SYSTEM, LIGHTING, & BURNING CONTROL Recommended Maximum Lead Length (Double Wire) When Using Wall Switch or Thermostat Wire Size Max. Length 14 GA. 100 FT. 16 GA. 64 FT. 18 GA. 40 FT. 20 GA. 25 FT. 22 GA. 16 FT.
  • Page 16: Vent Termination

    F - Clearance under veranda, porch, deck or balcony 12 inches (30cm) minimum. This appliance is approved with Kingsman flex vent system and also approved for use with Simpson Duravent Direct Vent G - Clearance from a perpendicular inside wall or outer corner to System, AmeriVent Direct Vent Pipe System and Selkirk Direct the edge of the vent terminal plate is 3”...
  • Page 17: General Venting Information

    This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex(Z-Flex)Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with Simpson-Duravent Direct Vent system, Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
  • Page 18 IMPORTANT: ALWAYS LOCATE THE STOVE IN SUCH A WAY AS TO MINIMIZE THE NUMBER OF OFFSETS AND/OR HORIZONTAL RUNS. A 1/4” VERTICAL RISE IS REQUIRED FOR EVERY 12” OF HORIZONTAL RUN. The following table shows the relationship between vertical and horizontal vent lengths and will help you to determine the correct vent lengths for optimum stove performance.
  • Page 19: Vent Pipe Assembly

    VENT PIPE ASSEMBLY Before joining the four inch flex pipe to stove or vent termination apply a bead of high temperature sealant (MIL PAC SEALANT IS RECOMMENDED) to the pipe and secure it with the (4) screws. If two pieces of 4" flex pipe are to be joined, the joint must be siliconed and secured with four screws.
  • Page 20 4. If optional fan kit has been purchased it should now be installed before stove is placed in its final position. 5. Place stove into position. Determine the lengths of the vertical and horizontal 7" pipes. Cut the 7" pipes to the correct length assuring that the following conditions have been met: The horizontal 7"...
  • Page 21: Vertical Vent Installation

    VERTICAL VENT INSTALLATION OPTIONAL ADJUSTABLE CLAMP SELF TAPPING SCREWS SELF TAPPING SCREWS TO SECURE RIGID PIPE TO TERMINATION An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed.
  • Page 22: Converting The Fdv350 Direct Vent To A Vented Fireplace

    6. The stove has now been converted to a vented appliance. (FV350) 7. Place approval label on label plate, over top of FDV350 Rating Plate. Be sure to line up so serial number of old unit is legible.
  • Page 23: Vent Installation For Vented Appliance

    VENT INSTALLATION FOR VENTED APPLIANCE VENTING INSTRUCTIONS NOTE: A chimney venting this stove shall not vent any other appliance. This appliance may be vented in various types of applications, 'A' Vent of solid fuel wood burning chimney. Masonry Clay lining and 'B' Vent liquid fuel gas chimney.
  • Page 24: Venting Kits And Components

    Product Number Description FDV350N Free Standing Direct Vent Stove - Natural Gas - Black FDV350LP Free Standing Direct Vent Stove - Liquid Propane - Black DOOR FRAME: (REQUIRED FOR EACH UNIT) F35DG Door Frame and Ceramic Glass - Gold F35DB Door Frame and Ceramic Glass - Black LOG SET: (REQUIRED FOR EACH UNIT) LOGF35...
  • Page 25: Replacement Parts List

    350- P217SI KNOB EXTENSION 1 1/2 - ON/OFF 350-P218SI KNOB EXTENSION 1 1/2- Hl/LO 350-310 CERAMIC GLASS FRONT - C/W THERMALCORD (FDV350) 350-309 CERAMIC GLASS SIDE - C/W THERMALCORD (FDV350) CONVERSION KITS: 350DV-CKNG CONVERSION KIT - NATURAL GAS - FDV350N...
  • Page 26: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System WARNIING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 27: Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.