Installation Instructions
Certified to: ANSI Z21.88-2002/CSA-2.33-2002, CAN/CGA 2.17-1991, CSA P.4.1-02
Listed Direct Vent Gas Fired Free Standing Room Heater
Stock #'s: FDV200N, FDV200LP, FDV200PN, FDV200PLP
Direct Vent Gas Stove
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
Warning: Improper installation, alteration, service or maintenance can cause
property damage, personal injury or loss of life. Refer to this manual.
Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
2340 Logan Ave., Winnipeg, Manitoba, Canada R2R 2V3
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where
not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
Listed Certified for USA. and Canada
Model Number FDV200 - FDV200P
"Free Standing"

FOR YOUR SAFETY

vicinity of this or any other appliance.
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
A Division of R-Co. Inc.
Ph: (204) 632-1962
Printed in Canada September 17, 2007 Part # 200-MAN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FDV200N and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kingsman FDV200N

  • Page 1: For Your Safety

    Certified to: ANSI Z21.88-2002/CSA-2.33-2002, CAN/CGA 2.17-1991, CSA P.4.1-02 Listed Direct Vent Gas Fired Free Standing Room Heater Model Number FDV200 - FDV200P Stock #’s: FDV200N, FDV200LP, FDV200PN, FDV200PLP “Free Standing” Direct Vent Gas Stove Read this complete manual before beginning installation.
  • Page 2 PRE-INSTALLATION QUESTIONS and ANSWERS Why does my fireplace or stove give off odour? It is normal for your fireplace to give off some odour. This is due to the curing of the paint, adhesives, silicones and any undetected oil from the manufacturing process as well as the finishing materials used with the installations (e.g.
  • Page 3: Table Of Contents

    Table of Contents Mobile home/manufactured housing installation ....4 Installation and operation ........5 Installation Requirements for the Commonwealth of Massachusetts .
  • Page 4: Mobile Home/Manufactured Housing Installation

    Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NCBS A225.1, and with CSA Z240.4 Mobile Home Standard in Canada. THE FDV200N, FDV200PN, FDV200LP and FDV200PLP MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE. Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada.
  • Page 5: Installation And Operation

    INSTALLATION AND OPERATION FDV200 FDV200P ⁄ ” ⁄ ” ⁄ ” ⁄ ” ⁄ ” ⁄ ” 15” 15” 4” Dia 4” Dia. ⁄ ” ⁄ ” 7” Dia. 7” Dia NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 6: Installation Requirements For The Commonwealth Of Massachusetts

    7. The venting system (chimney) of this appliance should be inspected at least once a year and if needed, your venting system should be cleaned. 8. Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapours and liquids.
  • Page 7: Locating Your Appliance

    LOCATING YOUR APPLIANCE THE FOLLOWING MINIMUM DISTANCES TO COMBUSTIBLES MUST BE OBSERVED TO ENSURE SAFE OPERATION OF YOUR STOVE. Minimum distance to combustibles 6” from side of unit 3” from back of unit 3” from side of unit in corner (45°) installation 4”...
  • Page 8: Gas Line Installation

    GAS LINE INSTALLATION This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 installation codes for Gas Burning Appliances and Equipment in Canada and the National Fuel Gas Code Z223.1 in the United States. NOTE: IF THE OPTIONAL FAN KIT IS TO BE INSTALLED IT IS HIGHLY RECOMMENDED THAT IT BE ATTACHED TO THE STOVE BEFORE THE STOVE IS PUT IN ITS FINAL POSITION.
  • Page 9: Gas Specifications

    FDV200 - FDV200P NG/LP GAS SPECIFICATIONS FUEL MAXIMUM INPUT CONTROL (BTU) HIGH NATURAL GAS MILLIVOLT 30,000 20,000 PROPANE GAS MILLIVOLT 26,000 20,000 GAS INLET SIZE 3/8”(SIT) # 35 3/8” # 51 FULL OPEN OPERATING AND MAINTENANCE INSTRUCTIONS This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 installation codes for Gas Burning Appliances and Equipment.
  • Page 10: General Glass Information

    The venting system (chimney) of this appliance should be inspected at least once a year and if needed, your venting system should be cleaned. Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapours and liquids.
  • Page 11: Installation Of Brick Panel Kit

    CAUTIONS AND WARNINGS DO NOT CLEAN WHEN THE GLASS IS HOT. THE USE OF SUBSTITUTE GLASS WILL VOID ALL PRODUCT WARRANTIES. CARE MUST BE TAKEN TO AVOID BREAKAGE OF THE GLASS. DO NOT OPERATE THIS STOVE WITHOUT THE GLASS DOORS OR WITH A BROKEN GLASS DOOR. DO NOT STRIKE OR ABUSE GLASS.
  • Page 12: Log Assembly

    Installation Instructions for LOGC200 Remove can of touchup paint from firebox ❺ ❹ Notch ❷ ❸ ❻ ❶ Notch 2nd Grate Bar Notch Notch Locating Tabs Log and Ember Chunk Kit ❷ ❶ Step 1: Locate the locating tabs 1A–1B and position the Step 2: Locate the locating tab 2A and position the hole on holes on the bottom of Log 1 onto the tabs.
  • Page 13: Optional Fan Kit Installation

    OPTIONAL FAN KIT INSTALLATION Note: Leg model shown, use the same mounting procedures for pedestal models. PARTS LIST: - Mounting bracket (4000-5000 only) - 1 Variable speed control with 2 male ends - 1 black knob - 1 speed nut - 2 fan mounting screws NOTE: THE FAN ADAPTER IS NOT USED ON 200 MODEL UNITS.
  • Page 14: Millivolt System, Lighting, & Burner Control

    MILLIVOLT SYSTEM, LIGHTING, & BURNING CONTROL Recommended Maximum Lead Length (Double Wire) When Using Wall Switch or Thermostat Wire Size Max. Length 14 GA. 100 FT. 16 GA. 64 FT. 18 GA. 40 FT. 20 GA. 25 FT. 22 GA. 16 FT.
  • Page 15: Vent Termination

    F - Clearance under veranda, porch, deck or balcony 12 inches (30cm) This appliance is approved with Kingsman flex vent system and also minimum. approved for use with Simpson Duravent Direct Vent System (model G - Clearance from a perpendicular inside wall or outer corner to the DV-GS series), AmeriVent Direct Vent pipe system and Selkirk Direct edge of the vent terminal plate is 3”...
  • Page 16: General Venting Information

    (ZDVDKA). Follow installation instructions provided by Simpson Duravent/Ameri-Vent/Selkirk Direct Temp for installation of pipe and adhere to the clearance to combustibles provided in this manual. Apply a bead of Mill Pac high temp sealant to all joints of pipes, adapters and termination, when using Kingsman venting and Simpson Duravent venting.
  • Page 17 IMPORTANT: ALWAYS LOCATE THE STOVE IN SUCH A WAY AS TO MINIMIZE THE NUMBER OF OFFSETS AND/OR HORIZONTAL RUNS. A 1/4” VERTICAL RISE IS REQUIRED FOR EVERY 12” OF HORIZONTAL RUN. The following table shows the relationship between vertical and horizontal vent lengths and will help you to determine the correct vent lengths for optimum stove performance.
  • Page 18 VENT PIPE ASSEMBLY Before joining the four inch flex pipe to stove or vent termination apply a bead of high temperature sealant (MIL PAC SEALANT IS RECOMMENDED) to the pipe and secure it with the (4) screws/washers. If two pieces of 4" flex pipe are to be joined, the joint must be siliconed and secured with screws.
  • Page 19: Vent Pipe Assembly

    4. If optional fan kit has been purchased it should now be installed before stove is placed in its final position. 5. Place stove into position. Determine the lengths of the vertical and horizontal 7" pipes. Cut the 7" pipes to the correct length assuring that the following conditions have been met: (i) The horizontal 7"...
  • Page 20: Vertical Venting Over 15 Feet

    VERTICAL VENTING OVER 15 FEET The Air Intake Plate must be adjusted down to the lowest position when venting over 15 ft. vertical. 15’ OR OVER VERTICAL VENTING AIR INTAKE PLATE ADJUSTMENT NOTE: Unit comes preset for vertical venting under 15 feet. Follow these instructions when venting exceeds 15 feet vertical.
  • Page 21: Vertical Vent Installation

    VERTICAL VENT INSTALLATION An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from chimney. When installing Attic Insulation Shield where the...
  • Page 22: Venting Kits And Components

    Product Number Description FDV200N Free Standing Direct Vent Leg Stove - Natural Gas - Painted Black FDV200LP Free Standing Direct Vent Leg Stove - Liquid Propane - Painted Black FDV200PN Free Standing Direct Vent Pedestal Stove - Natural Gas - Painted Black...
  • Page 23: Replacement Parts List

    350-P218SI KNOB EXTENSION 1 1/2- Hl/LO 200-310 CERAMIC GLASS FRONT - C/W THERMALCORD CONVERSION KITS: 200DV-CKNG CONVERSION KIT - NATURAL GAS - FDV200N – 200DV-CKLP CONVERSION KIT - LIQUID PROPANE - FDV200LP VALVE SYSTEM PARTS S.I.T. Valve System 200-BNGSI NG BURNER ASSEMBLY (complete with valve)
  • Page 24: Conversion Kit Instructions

    CONVERSION KIT INSTRUCTIONS PLEASE CONFIRM THAT STEP 4 IS UNDERSTOOD BEFORE PROCEEDING WITH CONVERSION. “WARNING” This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss...
  • Page 25: Gas Conversion Kit For Top Convertible Pilot

    GAS CONVERSION KIT FOR TOP CONVERTIBLE PILOT SERIES 019065X Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG Only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 26: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 27: Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.