Kingsman FDV200S Installation Instructions Manual

Free standing direct vent gas stove
Table of Contents

Advertisement

Quick Links

Model Numbers:
Certified to:
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
-WHAT TO DO IF YOU SMELL GAS
 Do not try to light any appliance.
 Do not touch any electrical switch; do not use any phone in your building.
 Leave the building immediately.
 Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
 If you cannot reach your gas supplier, call the fire department
-Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
Installation Instructions
Model Number FDV200S
Free Standing Direct Vent Gas Stove
FDV200SN, FDV200SNE, FDV200SNE2, FDV200SLP, FDV200SLPE, FDV200SLPE2
ANSI Z21.88-2017 • CSA 2.33-2017, CSA 2.17-2017
VENTED GAS FIREPLACE HEATER
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for future
reference.
For Propane Horizontal installations
the venting must be an additional one
foot above the minimum vertical rise
off the flue before going horizontal.
VENTED GAS FIREPLACE HEATER:
NOT FOR USE WITH SOLID FUEL.
A Division of R-Co. Inc.
2340 Logan Ave.
Winnipeg, Manitoba Canada
R2R 2V3 Ph.: (204) 632-1962
Printed in Canada September 11, 2019
Part# 200S-MAN17
TITAN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FDV200S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kingsman FDV200S

  • Page 1 Installation Instructions Model Number FDV200S Free Standing Direct Vent Gas Stove TITAN Model Numbers: FDV200SN, FDV200SNE, FDV200SNE2, FDV200SLP, FDV200SLPE, FDV200SLPE2 ANSI Z21.88-2017 • CSA 2.33-2017, CSA 2.17-2017 Certified to: VENTED GAS FIREPLACE HEATER This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
  • Page 2: Table Of Contents

    Configuration 3: Remote ON/OFF, Variable HI/LO, and Fan..............VENTING Vent Terminal Clearances.......................... General Venting Information........................Venting Routes and Components....................... 39-40 Horizontal Vent Installation......................... Horizontal Snorkel Terminations......................... Vertical Vent Installation..........................43-45 PARTS LIST FDV200S Parts List............................ 46-47 WARRANTY Glass Safety / Termination Cap Safety....................... Limited Lifetime Warranty...........................
  • Page 3: Safety Screen Attachment / Removal

    FDV200S Safety Screen Attachment / Removal Top Hook INSTALLATION: 1. Insert top of Screen Frame into bottom of stove top. 2. Engage Top Hooks into Top Slots. 3. Engage Bottom Hooks into Top Hook Bottom Slots. Safety Screen Frame Bottom Hook...
  • Page 4: Pre-Installation Questions And Answers / Operating Instructions

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 5: Annual Inspection List For Determining Safe Operation Of A Direct Vent Gas Fireplace

    Annual Inspection List for Determining Safe Operation of a Direct Vent Gas Fireplace Refer to this checklist for proper maintenance, safe use, and operation. See each section for more specific information. 1. Inspect and operate all pressure relief mechanisms (i.e., relief dampers, spring loaded door latches) installed on your appliance to verify relief mechanisms are free from obstruction to operate.
  • Page 6: Warnings, Installations, And Operations

    Warnings, Installations and Operations - Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the National Electrical Code;...
  • Page 7: Installation Requirements For The Commonwealth Of Massachusetts

    Installation Requirements for the Commonwealth of Massachusetts In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the requirements listed below.
  • Page 8: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 9: Fireplace Dimensions / Locating Your Appliance

    FDV200S Dimensions VENTING IS 4” / 7” Gas Inlet is located at the back of the unit. FDV200S Locating Your Appliance 3” 3” 6” 3” THE FOLLOWING MINIMUM DISTANCES TO 2-1/2” 4” COMBUSTIBLES MUST BE OBSERVED TO ENSURE SAFE OPERATION OF YOUR STOVE.
  • Page 10: Optional Fan Kit Installation

    FDV200S Optional Fan Installation (Part # F45FK)
  • Page 11: Split Receptacle- Switch Control Outside Of Fireplace

    Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
  • Page 12: F200Rl Brick Liner Installation

    FDV200RL Brick Liner Installation Installation of Brick Panel Kit: 1. Remove glass door as shown in door removal diagram. 2. Place Back Brick Panel up to rear of firebox, leaving bottom of panel slightly forward for support. 3. Remove left and right Brick Clips using a 1/4” nut driver. Do not discard Brick Clips. 4.
  • Page 13: Logc200 Log Installation

    LOGC200 Installation Instructions Locating Tabs ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Step 1: Step 2: Log 1 is The hole in the installed onto...
  • Page 14: Door And Glass Information

    Door and Glass Information FDV200S Screw Screw Glass Front Door Assembly Safety Screen Frame Assembly...
  • Page 15: Gas Line Installation

    1/2 PSIG (3.5 KPa). NOTE: The gas line connection may be made of 1/2” rigid pipe or an Approved Kingsman Flex Connector, such as FP15GC.
  • Page 16: Burner System Maintenance

    Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. ⚠ -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 17: Conversion Kit Instructions -Part A

    Conversion Kit Instructions -Part A Caution: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. PLEASE CONFIRM THAT STEP 4 IS UNDERSTOOD BEFORE PROCEEDING WITH CONVERSION. WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the...
  • Page 18: Gas Conversion For Top Convertible Pilot - Part B (Series 0190Xyz)

    Gas Conversion for Top Convertible Pilot – Part B (series 0190XYZ) Instructions for converting SIT 190 series pilot burner injector from NG to PROPANE and from PROPANE to NG only. This information should be considered as supplemental to the Appliance Manufacturer's Instructions.
  • Page 19: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C WARNING!- WARNING!-...
  • Page 20: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING This appliance has a pilot which must be lighted by hand. When Immediately call your gas supplier from a neighbour’s phone.
  • Page 21: Electronic Ignition Lighting Instructions

    Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING: A.
  • Page 22: Troubleshooting The Gas Control System

    Troubleshooting the Gas Control System ⚠ WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is...
  • Page 23: Component Locations

    FDV200S Component Locations - Top View (See Each Section For Connections & Wiring) PROFLAME 2 MILLIVOLT / PROFLAME 1 TOP VIEW TOP VIEW Gasline Flex Connection Gasline Flex Optional Connection Remote Receiver FRONT Variable Speed Valve FRONT Control for Battery...
  • Page 24 Proflame 2 –NE2 / LPE2 -IPI System Parts List- IPI PROFLAME 2 - COMPONENT PARTS IPI - PF1 and PF2 Common Components PART NO. DESCRIPTION PART NO. DESCRIPTION 1005-P001SI Valve IPI Proflame PF2 885.001 NG - Stepper 12. 1002-P033SI TC - Pilot Burner IPI (Assembled) NG 199.033 1005-P002SI Valve IPI Proflame PF2 885.002 LP - Stepper 13.
  • Page 25: Ifc Module And Remote Control

    Proflame 2 IFC Module and Remote Control LCD Display ON / OFF Key Thermostat Key Batteries UP / DOWN Arrow Key Mode Key IFC Module Button  Within 10 seconds press the button again until Pairing Remote Control: you hear it beep. Install the 3 AAA type batteries in the battery bay, ...
  • Page 26: Cold Climates - Cpi Setting - Proflame 2 Remote Control

    Cold Climates – CPI Setting - Proflame 2 Remote Control Use the CPI setting during cold weather, otherwise the fireplace may have a hard time starting up and establishing a flame. The CPI (Continuous Pilot Ignition) setting will keep the firebox and fireplace exhaust vent warm during cold weather. When the firebox and exhaust vent are warm, exhaust gasses will readily flow out of the firebox.
  • Page 27: Remote Flame Control, Room Thermostat

    Proflame 2 Remote Control...
  • Page 28: Smart Thermostat, Fan Speed Control, Remote Dimmer Control

    Note: When Smart Thermostat is activated, manual flame height adjustment is disabled. Note: This function is only available in Room Thermostat or Smart Thermostat Control Mode.
  • Page 30: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that Cover provides you with the option of having either a Standing- Pilot, or an intermittent igniting system. This alternating Backup mode is controlled by the CPI/IPI Switch (Continuous Pilot Battery Ignition/Intermittent Pilot Ignition) located on the IPI System Pack...
  • Page 31: Remote Control Operation

    Proflame 1 -Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart *thermostatic control of the appliance. *In the U.S.A *thermostats are not permitted for Vented Decorative Gas Fireplaces (ANSI Z21.50). Transmitter Remote Receiver Transmitter...
  • Page 32: Ipi Electronic Ignition Parts List - Standard System

    IPI Electronic Ignition Parts List – Standard System ITEM NO. PART NO. DESCRIPTION 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/Lo LP *1002-P047si Pilot Assembly-LP -24” Wire *1002-P033si Pilot Assembly-NG -24” Wire 1002-P017si Spark Electrode (with wire) *1002-P119si Spark Electrode (with wire- 35” Length) 1002-P903si Electrode Flame Sensor *1002-P910si...
  • Page 33: Configuration 1: Basic Manual Hi / Lo And Manual Off

    Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 34: Configuration 2: Remote On / Off And Manual Hi / Lo

    Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 35: Operating The Receiver Without Batteries For Gt / Egt / Gtm / Egtm Remote Controls

    Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivolt systems. -Millivolt Systems will also require Power Adapter P/N 1002-P850si. The Remote Receiver & IPI or Millivolt system can be powered by the AC Adapter. This is advantageous if you do not want to use batteries.
  • Page 36: Configuration 3: Remote On/Off, Variable Hi/Lo, And Fan

    Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan installation.
  • Page 37: Vent Terminal Clearances

    Vent Terminal Clearances Clearances are to the edge of the terminal plate. Add 6-3/4” to clearances to arrive at centerline. Local codes or regulations may require different clearances. WARNING: A HORIZONTAL VENT CERTIFIED GUARD (SAFETY CAGE) IS AVAILABLE WHEN REQUIRED BY LOCAL CODES. Canadian installations US installations Clearance above grade, veranda,...
  • Page 38: General Venting Information

    Metal Fab Sure-Seal DV for installation of pipe and adhere to the clearance to combustibles provided in this manual. Apply a bead of Mill Pac high temp sealant to all joints of pipes, adapters and termination, when using Kingsman Flex (Z- Flex) venting and Simpson Duravent venting.
  • Page 39: Venting Routes And Components

    FDV200S Venting Routes and Components Since it is very important that the vent system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be adhered to. See venting chart for total horizontal and vertical runs.
  • Page 40 FDV200S Venting Routes and Components (Continued) The following table shows the relationship between vertical and horizontal vent lengths and will help you to determine the correct vent lengths for optimum stove performance. How to use the Vent Table: 1. Determine the height of the system and the number of elbows required.
  • Page 41: Horizontal Vent Installation

    FDV200S Horizontal Vent Installation Wall Thimble Silicone and Screw Decorative Cover or Clamp Trim Ring 1” Minimum 2-1/2” Top of Horizontal Vent Caulk (Both Sides) 4” Top of 90° Elbow Silicone and Screw or Clamp All other existing pipes 1” clearance.
  • Page 42: Horizontal Snorkel Terminations

    Z47ST24 / Z47ST36 Horizontal Snorkel Terminations Two snorkel terminations are available if a vertical rise is necessary on the exterior side of a building: Z47ST24 (24” Tall, 14-1/2” Center to Center) Z47ST36 (36” Tall, 26-1/2” Center to Center) Follow standard horizontal venting installation procedures. If the Snorkel Termination is to be located below grade, a window well is recommended with adequate and proper drainage as per local codes.
  • Page 43 VERTICAL VENTING OVER 15 FEET The Air Intake Plate must be adjusted down to the lowest position when venting over 15 ft. vertical. 15’ OR OVER VERTICAL VENTING AIR INTAKE PLATE ADJUSTMENT NOTE: Unit comes preset for vertical venting under 15 feet. Follow these instructions when venting exceeds 15 feet vertical.
  • Page 44 FDV200S Vertical Vent Installation Framing Detail Attic Insulation Shield Fire Stop Using Flex Bends Use roof support and rigid pipe at roof level. Flex pipe is not permitted within roof support. When penetrating the roof a rigid galvanized pipe must be used. Attach flex pipe to the rigid pipe with high temperature sealant, secure with four screws assuring the flex pipe and rigid pipe are secured.
  • Page 45: Vertical Vent Installation

    FDV200S Vertical Vent Installation Clearance to perpendicular wall 24 inches FDVVSK: Vertical Vent Starter Kit (60 cm). (Recommended to prevent re- 12” Rule Starter Kit contains: Attic Insulation Shield, Decorative Ceiling Trim Ring, Level circulation of exhaust products. For additional Black Band, brass Band, Roof Support, Spacer Springs (6), Mill Pac.
  • Page 46: Parts List

    FDV200S Parts List -FDV200S KINGSMAN STOVE- 1006-P003SI Valve IPI Proflame PF1 886.003 LP - HI/LO FREE STANDING DIRECT VENT GAS STOVE 1002-P322SI IPI Module PF1 - 584.322 Listed for USA/Canada as a Vented Gas Fireplace Heater, 1002-P850SI IPI Power Adapter IPI - 584.850 AC Dual Burner, Ceramic Glass, Glowing Embers, 4/7”...
  • Page 47 Knob Extension 1-1/2” – ON/OFF - Millivolt 350-P218SI Knob Extension 1-1/2” HI/LO - Millivolt 200-310 Ceramic Glass Front c/w Thermalcord KINGSMAN FIREPLACE VENTING Horizontal Vent Starter Kit - (Direct Vent FDVHSK Stoves) Starter Kit Contains: Horizontal Vent Termination, Zero Clearance Wall Sleeve, Black Wall Trim Ring, 7"...
  • Page 48: Glass Safety / Termination Cap Safety

    -Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Any safety screen, guard, or barrier removed for servicing the appliance, must be replaced prior to operating the appliance.
  • Page 49: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

Table of Contents