Kingsman FV5000 Installation Instructions Manual

Free standing vented gas stove, room heater

Advertisement

Installation Instructions
Listed Certified for USA. and Canada
Certified to: ANSI 21.88b-2003, CSA 2.33b-2003, CGA 2.17-M91, CSA P.4.1-02
Model Number FV5000
"Free Standing"
Vented Gas Stove
Room Heater
f i r e - p a r t s . c o m
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
A Division of R-Co. Inc.
2340 Logan Ave., Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
Warning: improper Installation, adjustment, alteration, service or maintenance can cause property damage,
personal injury or loss of life. Refer to this manual. Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Printed in Canada 03/04/07 Part # 5000-P951CP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FV5000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingsman FV5000

  • Page 1 Installation Instructions Listed Certified for USA. and Canada Certified to: ANSI 21.88b-2003, CSA 2.33b-2003, CGA 2.17-M91, CSA P.4.1-02 Model Number FV5000 “Free Standing” Vented Gas Stove Room Heater f i r e - p a r t s . c o m Read this complete manual before beginning installation.
  • Page 2 PRE-INSTALLATION QUESTIONS and ANSWERS Why does my fireplace or stove give off odour? It is normal for your fireplace to give off some odour. This is due to the curing of the paint, adhesives, silicones and any undetected oil from the manufacturing process as well as the finishing materials used with the installations (e.g.
  • Page 3: Table Of Contents

    Table of Contents Installation and operation ......4 Locating your appliance ......5 Gas line installation .
  • Page 4: Installation And Operation

    INSTALLATION AND OPERATION 27 3/4” 22 3/4” 17” 23 1/4” 19” 4” 6 1/4” Gas inlet is located on the back of the unit. INSTALLATION REGULATIONS This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN\CGA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States.
  • Page 5: Locating Your Appliance

    7. The venting system (chimney) of this appliance should be inspected at least once a year and if needed, your venting system should be cleaned. 8. Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapours and liquids.
  • Page 6: Gas Line Installation

    GAS LINE INSTALLATION This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN\CGA-B149.1 or .2 installation codes for Gas Burning Appliances and Equipment in Canada and the National Fuel Gas Code Z223.1 in the United States. NOTE: IF THE OPTIONAL FAN KIT IS TO BE INSTALLED IT IS HIGHLY RECOMMENDED THAT IT BE ATTACHED TO THE STOVE BEFORE THE STOVE IS PUT IN ITS FINAL POSITION.
  • Page 7: Gas Specifications

    GAS SPECIFICATIONS FUEL MAXIMUM INPUT MAXIMUM OUTPUT CONTROL (BTU) (BTU) HIGH HIGH NATURAL GAS MILLIVOLT 32,000 25,000 23,700 PROPANE GAS MILLIVOLT 32,000 22,500 24,320 MAXIMUN EFFICIENCY (FAN ON) (78 NG), (80% LP) GAS INLET SIZE 1/2”(WR) GAS INLET SIZE 3/8”(SIT) GAS SUPPLY MINIMUM NORMAL...
  • Page 8: General Glass Information

    The venting system (chimney) of this appliance should be inspected at least once a year and if needed, your venting system should be cleaned. Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapours and liquids.
  • Page 9: Log Assembly

    CAUTIONS AND WARNINGS DO NOT CLEAN WHEN THE GLASS IS HOT. THE USE OF SUBSTITUTE GLASS WILL VOID ALL PRODUCT WARRANTIES. CARE MUST BE TAKEN TO AVOID BREAKAGE OF THE GLASS. DO NOT OPERATE THIS STOVE WITHOUT THE GLASS DOORS OR WITH A BROKEN GLASS DOOR. DO NOT STRIKE OR ABUSE GLASS.
  • Page 10: Log Placement

    f i r e - p a r t s . c o m...
  • Page 11 f i r e - p a r t s . c o m...
  • Page 12: Optional Fan Kit Installation

    FV/FDV 5000 OPTIONAL FAN KIT INSTALLATION Caution: Do not connect any wires from the fan assembly to the Gas Valve. f i r e - p a r t s . c o m NOTE: FOR EASE OF INSTALLATION THE FAN KIT SHOULD BE INSTALLED BEFORE THE STOVE IS PUT IN ITS FINAL POSITION.
  • Page 13: Millivolt System, Lighting, & Burner Control

    MILLIVOLT SYSTEM, LIGHTING, & BURNING CONTROL LIGHTING INSTRUCTIONS 1. Open access door on front of unit. 2. Push in gas control knob slightly and turn clockwise Use on 820633 to "OFF". NOTE: Knob cannot be turned from and 820634 "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
  • Page 14: Vent Installation

    VENT INSTALLATION f i r e - p a r t s . c o m VENTING INSTRUCTIONS NOTE: A chimney venting this stove shall not vent any other appliance. This appliance may be vented in various types of applications, 'A' Vent of solid fuel wood burning chimney.
  • Page 15: Accessory List

    Remote Control - Basic - Natural Gas (On/Off, Hi/Lo Flame Adjustment) RMCBP Remote Control - Basic - Liquid Propane (On/Off, Hi/Lo Flame Adjustment) DCHS Remote Control Heatshield REPLACEMENT PARTS FOR FV5000 5000 - 190 Glass - Robax (13.25” x 20”) 1000 - 306 Thermalcord For Glass...
  • Page 16 If Serial Number is BETWEEN 4468-4740 SYSTEM #2 New Top Convertible SIT system: 5000 - VBLPSI LP SIT BURNER ASSEMBLY C/W VALVE 5000 - VBNGSI NG SIT BURNER ASSEMBLY C/W VALVE 1000-P136WR Thermopile GOAI-524 1001-P069SI Electrode Sparker 915.069 TC SIT 1001-P216SI Thermocouple 290.216 TC SIT 1001-P165SI...
  • Page 17: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 18: Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.