4 DIAGNOSTICS
Field
MAC Abort
Cntr
Socket Port
State
Description
INIT_STOPPED
The DCX3200 is in the interactive initialization state and
the TransMode has stopped.
RUN_WAIT_DC_
The DCX3200 is in the interactive state and waiting for
OR_C
the default configuration or the contention channel list
messages.
RUNNING
Interactive state is running, sending idle messages, and
waiting for any prepare for poll or MAC messages.
RUN_STOPPED
The interactive run state has stopped and DCX3200 is
waiting for status or a transmission control message.
INVALID
The interactive state is unknown or invalid.
This counter increments every time the MAC layer reaches the cell abort
count limit. It is reset by the successful upstream transmission of a cell: for
example, when the DCX3200 receives an ACK. If the counter reaches the
MAC abort count limit, the DCX3200 assumes the MAC layer is unavailable
due to noise, congestion, or some other problem. The DCX3200 stops
transmitting data upstream, reports an error to the calling function, and
attempts to re-enter the network using the initialization process. 0000 is
displayed as the default or if the MAC Abort CNTR is not configured or
unknown.
The socket mode and activity:
UNUSED — The socket is not being used.
OPENED — The socket is open.
READY — The socket is ready to send or receive.
RECEIVING — The socket is receiving data from the application server.
SENDING — The socket is sending data to the application server.
UNKNOWN — The socket state is invalid or unknown.