9. Allow the water to flow until all air is released from the supply hoses.
10. Once the system is in full flow, turn the power switch to the ON position.

4.3 Hot Water Operation

THE WATER TEMPERATURE MAY BECOME VERY HOT
1. Once the unit has started, perform the following procedures with the temperature control valve open but, in the
cold position.
a)
Inspect the system for any water, oil or fuel leaks. If a leak is noted, Turn The Unit OFF Immediately. Be
sure that all damaged parts are replaced and that all mechanical problems have been corrected prior to
proceeding.
b)
Inspect discharge hoses for kinking, cuts and leaks. If a cut or leak has been noted, Turn the Unit OFF
Immediately. Replace damaged hose and ensure all mechanical problems have been corrected prior to
proceeding.
2. Turn the temperature control valve counter-clockwise (CCW) to the desired temperature.
NOTE: Upon initial start-up, water will to begin heat in approximately 20 seconds and will reach maximum
temperature in approximately 2 ½ minutes. During initial temperature setting, move the temperature control
valve slowly allowing time for the thermometer to register the accurate temperature. Be extremely cautious when
adjusting the temperature to avoid the possibility of burns.

4.4 Solution Injector Operation

1. Turn the water heater ON and begin flowing heated water to the showerheads and spray wands.
2. Fully immerse solution pickup in the solution container.
3. Once the unit is running and the solution has been filled, turn the switch to the ON position to activate the injector.
4. When the unit is operating, liquid will be drawn from the solution container and a 'clicking' sound will be heard.
5. When finished using the decon solution, siphon water through the system, to flush the decon solution.
6. When finished flushing the injector system, turn off the injector by turning the switch to the OFF position.
95226-01
This document contains information proprietary to REEVES EMS, LLC and is intended solely for use by its customers. No portion of this document may
be reproduced for release to a third party without written consent from REEVES EMS, LLC
WARNING
RISK OF BURN