5.3 Maintenance – Every 6 Months
Replace Fuel Filter – Remove old filter by spinning it off counter-clockwise (CCW). Place new filter in place and
spin it on clockwise (CW) until it is hand tight.
5.4 Maintenance – Every 12 Months
Test Voltage & Amp Draw – Use a volt meter and amp meter to test the machine for correct voltage and
amperage. If you do not have these instruments or do not know how to use them; this procedure should be
perform by an authorized service technician.
Inspect Fuel Pump Internal Filter – This procedure must be performed by an authorized service technician.
Check Burner Electrodes – This procedure should be performed by an authorized service technician.
Replace Fuel Nozzle – This procedure should be performed by an authorized service technician.
Clean Fuel Pickup In-Line Screen – This procedure should be performed by an authorized service technician.
5.5 Maintenance – Seasonal
Winterizing – For storage and transportation purposes in subfreezing ambient temperatures, it will be necessary
to winterize the unit. This unit must be protected to the lowest incurred temperature for the following reasons:
1. If any part of the system becomes frozen; excessive pressure may build up in the unit which could cause
the unit to burst resulting in possible serious injury to the operator or bystanders.
2. Freeze damage is not covered by warranty.
If you must store the unit in an area where the temperature may fall below 32 degree F, you can protect the unit
by following the procedures below.
1. Remove all discharge and supply hoses.
2. Connect an air fitting from an air hose to the water inlet
side of the unit.
3. Blow compressed air, into the system to remove all
water from the unit.
4. Remove the injector strainer cup, drain the remaining
water, and replace the cup loosely.
5. Remove injector outer cylinder; push straight up on the
piston to drain remaining water. Replace the outer
cylinder on the injector.

5.6 Solution Injector Maintenance

Rinse the injector areas after using the unit. To do this, insert suction tube into a container of clean water and
inject for 5 minutes.
Soak entire disassembled unit in soapy water prior to installing after non-use period.
Replace injection seals annually to ensure precise injection.
Complete maintenance and seal kits are available.
Do not use tools when servicing or disassembling unit.
This unit was tested prior to shipping.
95226-01
This document contains information proprietary to REEVES EMS, LLC and is intended solely for use by its customers. No portion of this document may
be reproduced for release to a third party without written consent from REEVES EMS, LLC
16
.
REEVES EMS, LLC

Advertisement

Table of Contents
loading

This manual is also suitable for:

G2s

Table of Contents