5.1 Maintenance – Daily
Inspect Electrical Cord – Detach unit from power source and inspect electrical cords to ensure they are
serviceable. If damage is noted, replace cord before operating the unit.
Test GFCI – If applicable, test the GFCI. Testing varies according to the specific GFCI.
Test Gauges – If gauges do not operate properly, contact REEVES EMS, for replacement gauges or control
panel.
Fuel Leak Inspection – If a fuel leak is noted, shut down the unit immediately. Be sure that all damaged parts
are replaced and all mechanical problems are corrected before restarting. If additional assistance is needed,
contact REEVES EMS.
Water Leak Inspection – If a leak has been found, promptly eliminate any leaks found in the pumping system by
removing suspected parts. Apply thread sealant to the threads and reinstall. If additional assistance is needed,
contact REEVES EMS.
Hose Inspection – Inspect hoses for kinks, cuts, or leaks. If a cut and or leak is found, replace hose before
restarting the unit. Do not use hose if damage is present. If additional assistance is needed, contact REEVES
EMS.
Water Strainer Inspection – Ensure the water strainers are clean and free of any foreign objects. The system is
standard with an injector strainer, located on the inlet side of the injector and has an optional main water supply
strainer. Periodic cleaning of the water strainer will help prevent problems. As a strainer becomes clogged with
foreign material, it restricts proper flow of water to pump. This can result in cavitations which will cause premature
failure. Remove strainer screens, inspect, clean, and or replace.
Quick Coupler Inspection – There are o-ring seals inside the couplers which will deteriorate. To replace, install
a replacement o-ring to correct the leak. (Additional o-rings can be purchased from your dealer).
Decontamination Solution Level – Check the solution level in the tank located under the unit. If level is low,
refill with proper decontamination solution.