INSTALLATION
Notice:
If the signal wire has to be bought separately, choose electric wire above 0.75mm.
If the interconnection cord for power supply has to be replaced, please see the
following table for reference.
2700W(10000BTU/h)
3000W(11000BTU/h) -4000W(15000BTU/h)
4500W(18000BTU/h) -8000W(28000BTU/h)
WARNING:
Please take the electric circuit diagram attached to the indoor/outdoor units as major
reference while installing.
The power wire and signal wire between the indoor/outdoor units must be connected
one by one as per corresponding number on the wiring terminal board.
The connecting cables must be clipped together.
Special cable must be used to connect indoor unit and outdoor unit. It should be ensured
that the terminals are not influenced by external force. Poor connection may cause fire.
The electric box cover must be mounted and secured in position, otherwise fire or electrical
shock may occur because of dust or moisture.
The temperature of refrigerant circuit will be high, please keep the interconnection cable away
from the copper tube.
All the models shall be connected with the mains which has system impedance limitations.
While installing the unit, please see the following table for impedance information or
consult with the supply authority.
R410A
series
MODEL
3500W (12000BTU/h)
5100W (18000BTU/h)
6800W (18000BTU/h)
SPECS (Interconnection cord)
1.0mm
1.5mm
2.5mm
0.219
0.186
0.124
8
2
2
2
2