Operation

DISPLAY
There are two display modes on the Culligan
is initially set to turn off if there has been no keyboard activity after a 1 minute period. Touching any key will relight
the display. The display can be set so that it will always display the time. For information on changing the display
lighting option, refer to the programming section.
REGENERATION
There are several conditions that will cause the control to trip a regeneration. The 'REGEN' enunciator will light when
the control has signaled for a regeneration. The 'REGEN' enunciator will flash while the control is in regeneration.
The following are conditions that will call for regeneration:
1.
When the Aqua-Sensor
2.
When the Soft-Minder
3.
When the time clock has counted past the set number of days.
4.
At the preset time, when the number of days without a regeneration is equal to the days set in menu #8A.
5.
At the preset time, when the 'REGEN.' button is depressed once. 'REGEN.' will light.
6.
Immediately, when the 'REGEN." button is depressed twice. 'REGEN.' will light and blink.
7.
Immediately, if power to the unit has been off for more than 3 hours.
If dip switch 6 is in the ON position, the unit will begin a regeneration immediately for instances 1 and 2. With dip
swith 6 in the OFF position, the regeneration will not begin until the preset regeneration time.
START-UP
NOTICE: A sanitizing agent is added to the softener at the factory. Flush the tank to drain with a minimum of 40
gallons of water, or initiate a full regeneration cycle, prior to putting the unit into service.
Close the main water supply valve.
Set the Cul-Flo-Valv
Ensure that all faucets at the installation site are closed.
Direct the drain line discharge into a bucket where flow can be observed.
Plug the transformer into a 120 Volt, 60 Hz, single-phase receptacle.
Wait 1 minute for the control to energize the motor and home itself.
Set the timer to the correct time of day.
Open the main supply valve.
Initiate an immediate regeneration to move the control into the backwash position.
Refer to the section on manual cycling for information on cycling the control through its positions.
When in the backwash position, slowly shift the bypass to the soft water position until water flows.
Allow the tank to fill slowly until water flows from the drain line.
When flow to drain is established, open the bypass fully. Watch the drain line discharge for signs of resin. If
signs of resin particles appear, reduce the flow. Increase the flow again when resin no longer appears in the
discharge.
When the unit is filled with water, return the timer to the service position and proceed with setting the
microprocessor. Refer to the programming section.
NOTICE: Unplugging the Culligan
programmed in, the settings will be stored indefinitely. In the event of a power failure the time-of-day setting will
be stored for 1-2 days. If longer time storage is necessary, a battery backup is available. Refer to the Service
Manual for additional information.
20
CULLIGAN SILVER SERIES
®
probe senses the hardness in the Cullex
®
meter has recorded the passage of a predetermined number of gallons.
®
to the bypass position.
®
Silver Series water softener will not affect any of the timer settings. Once
®
WATER SOFTENER
microprocessor. As shipped from the factory, the display of the board
media.
®