night cooling
Menu
1.9.9
start temp. exhaust air
Setting range: 20 – 30 °C
Default value: 25 °C
min diff. outdoor-exhaust
Setting range: 3 – 10 °C
Default value: 6 °C
Activate night cooling here.
When the temperature in the house is high and the outdoor temperature
is lower, a cooling effect can be obtained by forcing the ventilation.
If the temperature difference between the exhaust air and the outdoor
air temperature is greater than the set value ("min diff. outdoor-exhaust")
and the exhaust air temperature is higher than the set value ("start temp.
exhaust air") run the ventilation at speed 4 until one of the conditions is
no longer met.
Caution
Night cooling can only be activated when house heating has been deac-
tivated. This is done in menu 4.2.