CBX ELECTRICAL CONNECTIONS
OUTPUT 1 and 2 CONNECTIONS USING EXTERNAL POWER
OUTPUT 3 CONNECTIONS USING DS8100A POWER (CBX500 Only)
Output Device
Output Device
Power Reference
Output
Signal
Figure 38 - Open Emitter Output Using External Power
Output Device
Output
Signal
Output Device
Ground Reference
Figure 39 - Open Collector Output Using External Power
Power to
Output Device
Output
Output Device
Signal
Reference
Figure 40 - Output 3 Using DS8100A Power
Power to
Output Device
Output
Output Device
Signal
Ground Reference
Figure 41 - Output 3 Using DS8100A Power
Output Device
Output Device
3
33