TECHNICAL FEATURES
SOFTWARE FEATURES
Readable Codes
Code Selection
Headers and Terminators
Operating Modes
Configuration Modes
Parameter Storage
ENVIRONMENTAL FEATURES
Operating Temperature
Storage Temperature
Humidity
Ambient light immunity
Vibration Resistance
EN 60068-2-6
2 hours on each axis
Shock Resistance:
EN 60068-2-27
3 shocks on each axis
Protection Class
EN 60529
PHYSICAL FEATURES
Mechanical Dimensions
Weight
* sealed connectors required; including the Harting RJ Industrial® Push Pull Ethernet connector for
older Ethernet models.
Interleaved 2/5
Code 39 Standard
Codabar
Code 128
GS1-128 (ex EAN 128)
Code 93 (standard and full ASCII)
EAN/UPC (including Add-on 2 and Add-on 5)
GS1 DataBar (including Limited and Expanded)
Up to 10 codes during one reading phase
Up to 128-byte headers and 128-byte terminators
On Line, Serial On Line, Automatic, Test, PackTrack™,
Continuous
Genius™ utility program
Non-volatile internal FLASH
0° to +50 °C (+32° to +122 °F)
-20° to +70 °C (-4° to +158 °F)
90% non condensing
Linear Models
14 mm @ 2 to 10 Hz
1.5 mm @ 13 to 55 Hz
2 g @ 70 to 200 Hz
30 g; 11 ms
Linear Models
217 x 172.5 x 126.6 mm
(8.54 x 6.79 x 4.98 in)
5 kg (11 lbs.)
36000 lux
Oscillating Mirror Models
1.5 mm @ 5 to 9.1 Hz
0.5 g @ 9.1 to 150 Hz
15 g; 11 ms
IP64*
Oscillating Mirror Models
275.1 x 192.3 x 254 mm
(10.83 x 7.57 x 10 in)
6.4 kg (14 lbs.)