11
Problem
Reading:
it is not possible to read the target
barcode (always returns No Read)
Communication:
the device is not transmitting anything
to the host.
Communication:
data do not appear on the terminal.
Communication:
data transferred to the host are
incorrect, corrupted or incomplete.
110
TROUBLESHOOTING GUIDE
Suggestion
Check synchronization of reading pulse with
object to read.
Is the scan line correctly positioned?
Place barcode in the center of scan line and
run TEST MODE (selectable by Genius™ as
Operating Modes).
If you still have troubles, check the following:
Is the reading distance within that allowed
(see reading diagrams)?
Is the Tilt angle too large?
Is the Skew angle less than 10° (direct
reflection)?
Choose the CODE tab and enable
different
Pharmacode). LENGTH = Variable.
Is the barcode quality sufficient?
If you had no success, try to perform the test
using the BARCODE TEST CHART included
with the product.
If working in PackTrack™ mode, verify that
the coordinates (in particular the Y axis) are
correct.
Is serial cable connected?
Is correct wiring respected?
If using MAIN RS232 or RS485 interface, is
the reference ground connected to proper
SGND Main Isolated (also referred to as
GND_ISO)?
completely different from GND power ground.
If using CBX, be sure the RS485 termination
switch is positioned to OFF.
Are serial host settings equivalent to serial
device setting?
In the Genius™ program enable the Data
Communication
Port\Data Tx parameter.
In the Genius™ program select the Data
Communication Settings/Data Format folder
and check for HEADER, TERMINATOR,
SEPARATOR and FILL CHAR values.
Check the CODE FIELD LENGTH value, too.
Are the COM port parameters correctly
assigned?
DS8100A REFERENCE MANUAL
code
types
Be
careful
that
Settings/Main-Auxiliary
(except
it
is
not