Leave parameter 'Enable Annex D/T.38 FAX Relay' at its default unless your technical
3.
requirements differ.
Select the coder (i.e., vocoder) that best suits your VoIP system requirements. The default
4.
coder is: G.7231 30 msec. To program the entire list of coders you want the MP-11x to use,
click the button on the left side of the '1
coders appear. Select coders according to your system requirements. Note that coders
higher on the list are preferred and take precedence over coders lower on the list.
Note:
Map outgoing calls to IP addresses (when Gatekeeper isn't used) by completing these steps:
5.
Click the arrow button next to the 'Tel to IP Routing Table' label; the 'Tel to IP Routing'
screen opens.
Any telephone number whose destination number matches the prefix defined in the
'Destination Phone Prefix' field and whose source number matches the prefix defined in
the adjacent 'Source Phone Prefix' field, is sent to the IP address entered in the 'IP
Address' field.
Click the Submit button; the 'Tel to IP Routing' table is automatically updated.
Click Quick Setup; you're returned to the 'Quick Setup' screen.
For more information on the 'Tel to IP Routing' table refer to the MP-11x H.323 User's
Manual.
Allocate MP-11x endpoints (analog lines) and their corresponding phone numbers to
6.
incoming IP calls by completing these steps:
Click the arrow button next to the 'Endpoint Phone Number' label; the 'Endpoint Phone
Numbers' screen opens.
Enter the number of a channel, starting with 1, (or a group of channels), under the
'Channel(s)' column (for example 1-4 for the first 4 endpoints).
Assign each channel a phone number (for a group of channels, define the first number
in an ordered sequence). For an example of connecting two MP-118 devices, refer to
Section
Click the Submit button; the 'Endpoint Phone Number' table is automatically updated.
Click Quick Setup; you're returned to the 'Quick Setup' screen.
Click the Reset button and click OK in the prompt; The MP-11x applies the changes and
7.
restarts. This takes approximately 2 minutes to complete. When the MP-11x has finished
restarting, the Power and Ready LEDs on the front panel are lit green.
Note:
MP-11x
The preferred coder is the coder that the MP-11x uses as a first choice for all
connections. If the far end gateway does not use this coder, the MP-11x
negotiates with the far end gateway to select a coder that both sides can use.
3.4.4
on page 23.
H.323 users should continue with Section
MP-118 Devices
on page 23.