Available languages

Gas Connection to Natural Gas or Local LP Gas
WARNING
Explosion Hazard
Use a new CSA International approved "outdoor"
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 11" (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
This installation must conform with local codes and ordinances.
In the absence of local codes, installations must conform with
either the National Fuel Gas Code ANSI Z223.1 - latest edition, or
CAN/CGA-B149.1 Natural Gas and Propane installation code.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
1. Make gas connections.
A combination of pipe fittings must be used to connect the
sear burner to the existing gas line.
If local codes permit, use an outdoor flexible stainless
steel tubing gas connector, design-certified by CSA
International, to connect the sear burner to the rigid gas
supply line. A
" diameter line is recommended. Using a
wrench to tighten, connect the gas supply to the sear
burner. Use pipe-joint compound on all non-flared male
threads. Do not kink or damage the flexible connector
when moving the sear burner.
Pipe-joint compounds suitable for use with LP gas must
be used. Do not use TEFLON
A. New CSA International approved
"outdoor" flexible gas supply line
B. Rear of sear burner
C. To Natural gas or Local LP gas supply
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
®†
tape.
A
B
C
2. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
3. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
Plug in Sear Burner
NOTE: This built-in outdoor sear burner comes with a large
5000 mAmp power transformer/plug assembly for the sear
burner igniters. Follow the instructions for plugging in and
mounting the power transformer. Keep any electrical supply cord
away from any heated surfaces.
1. Plug the single-prong plug into the receptacle on the left
underside of the sear burner.
A. Single-prong plug
2. Locate or build a non-combustible surface inside the island
cabinet to mount the power transformer. It must be to the left
side of the sear burner at a minimum of 3" (7.6 cm) from the
side and 4" (10.2 cm) below the bottom of the sear burner.
3. Mount the power transformer to the mounting surface using
4 #8 screws (not supplied) that are the proper type and length
for the transformer and the mounting surface. It must be
mounted with the wire for the single-prong plug upward or
toward the sear burner.
NOTE: The cord must be properly mounted with a cord
retention device so that its 3-prong plug will not touch the
ground when it is unplugged.