KitchenAid W10117506B Installation Instructions And Use And Care Manual page 11

Outdoor built-in sear burner
Table of Contents

Advertisement

Available languages

Available languages

The 20 lb LP gas fuel tank must be mounted and secured.
Door Style Tank Tray
1. Open cabinet doors.
2. Pull out the tank tray.
3. Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of the
20 lb LP gas fuel tank to secure.
A
A. Locking screw
B. Mounting hole
C. Bottom collar
5. Slide tank tray back into the cabinet.
6. Close cabinet doors.
Local LP Gas Supply Conversion
Conversion must be made by a qualified gas technician. The
qualified gas technician shall provide the gas supply to the
selected sear burner location in accordance with the National
Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local
codes. For conversion to local LP, the convertible regulator in the
conversion kit supplied with the sear burner must be used.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition. The qualified
LP gas technician shall provide the LP gas supply to the selected
sear burner location in accordance with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 and local codes.
Follow instructions for converting to local LP gas in the "Gas
Conversions" section.
A. New CSA International approved
"outdoor" flexible gas supply line
B. Rear of sear burner
C. To local LP gas supply
Tank tray
B
C
A
B
C
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the sear
burner and should be in a location that allows ease of opening
and closing. Do not block access to the shutoff valve. The valve
is for turning on or shutting off gas to the sear burner.
A
A. Gas supply line
B. Shutoff valve "open" position
C. To sear burner
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected sear burner location in accordance with
the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest
edition, and local codes. For conversion to Natural gas, the
Natural gas conversion kit supplied with the sear burner must be
used.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
To convert to Natural gas, the Natural Gas Conversion Kit
supplied with the sear burner must be used. Follow instructions
for converting to Natural gas in the "Gas Conversions" section.
A. New CSA International approved
"outdoor" flexible gas supply line
B. Rear of sear burner
C. To Natural gas supply
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the sear
burner and should be in a location that allows ease of opening
and closing. Do not block access to the shutoff valve. The valve
is for turning on or shutting off gas to the sear burner.
A
A. Gas supply line
B. Shutoff valve "open" position
C. To sear burner
B
C
A
B
C
B
C
11