Smart Inflate™ Measuring Technology This Physio Logic™ monitor uses trend-setting Smart Inflate™ Technology to detect your blood pressure. With one touch of a button, it will automatically start to inflate and determine your blood pressure by analysing your pressure oscillations while inflating.
Blood Pressure Standard The Joint National Committee on prevention, detection, evalua- tion, and treatment of high blood pressure has developed a blood pressure standard, according to which areas of low and high risk blood pressure are identified. This standard is a guideline as blood pressure varies among different people and different age groups...
Before Taking a Measurement To help you obtain more accurate readings: • Urinate if necessary. • Remove any clothing and jewellery from your left arm. Placing the cuff on anything other than bare skin can result in an inaccurate reading. •...
Name / Function of Each Part Date / Time - Set button On / Off / Start button Memory recall button LCD display Battery compartment Arm cuff Air tube and connector...
Display Explanation Date and time Systolic pressure Diastolic pressure Pulse rate Appears when Appears when blood measurement value is pressure reading is higher stored in memory or is than 160 mmHg (sys.) or recalled from memory. 95 mmHg (dia.) Appears when batteries Shows the pulse rate per should be replaced.
Recalling Memory 1. To recall stored blood pressure readings from memory, simply press the Memory button. The last set of memorized readings will be displayed. 2. Another press of the Memory button will recall the previous set of readings. Time Adjustment 1.
Applying the Arm Cuff 1. Insert the cuff’s connecting tube into the unit. 2. Unwrap the arm cuff, leaving the “Index” end of the cuff through the D-ring of the cuff. 3. Put your left arm through the cuff loop. Position the artery mark ( ) at the middle of your arm above the elbow, in line with your middle finger.
Taking a Measurement 1. Press the On / Off / Start button. All displays will appear for approximately one second before returning to “0”. 2. The unit will automatically start to inflate and begin to measure your blood pressure. During inflation, a changing measure of the cuff pressure will be shown on the display.
Troubleshooting Symptom: No display when the On / Off / Start button is pressed. Correction: If the batteries have run down, replace them with new alkaline batteries. If the batteries are not in the correct position, re-insert them with the correct polarities. Symptom: mark shown on display or the blood pressure value is displayed excessively low (high).