Problem:
The socket will not consistently operate remotely.
Solution:
The controller/Lightwave Link may be encountering interference
or may be at the edge of its reliable range of operation. First, ensure that
there are no large pieces of metal or bodies of water in the path of the
transmission. If the problem persists, try moving the controller/Link closer to
the socket, or consider using a LightwaveRF Signal Booster to extend the
range by relaying the signal between controller and socket.
Problem:
The socket wont turn on/o
/ flashing amber & blue lights.
Solution:
The socket is locked. This may have been done using a Socket
Locker or from the LightwaveRF App. If it is locked on, then the socket will
not turn o
manually. If it is locked o , the socket will not turn on manually.
To unlock the socket, press the unlock button on the Socket Locker or
smartphone App. If this is not possible, the sockets can be reset by turning
of mains power to the circuit for a period of 30 seconds.