Cino FuzzyScan Quick Start Manual

Cino FuzzyScan Quick Start Manual

Bluetooth cordless image scanner
Hide thumbs Also See for FuzzyScan:

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FuzzyScan and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cino FuzzyScan

  • Page 2: Getting Familiar With Your Fuzzyscan

    Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Bluetooth Cordless Image Scanner. Powered by the combination of cutting-edge FuzzyScan 2.0 Imaging Technology and Bluetooth 2.1 EDR wireless technology, it not only provides outstanding reading performance, but also delivers the convenience and freedom of mobility.
  • Page 3: Install The Battery

    Preparations before Using Install the Battery Ensure the battery contacts of the battery pack are facing the charging contacts inside the battery cavity. Slide the battery pack into the battery cavity until hearing a click sound before locking it with the end cap.
  • Page 4: Decide Your Radio Link Mode

    Decide Your Radio Link Mode The FuzzyScan Bluetooth image scanner provides several radio link modes to communicate with most host devices. When the Bluetooth-enabled host device is not available, it can work with the smart cradle in PAIR mode (one to...
  • Page 5 The default host interface of smart cradle is preset to USB HID. If you want to set the host interface to USB COM, you have to install the USB virtual COM software driver into your host device before using the scanner. Please visit the CINO website to download the software driver.
  • Page 6 Use FuzzyScan in PICO Mode Ensure the battery is fully charged and choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device. PS/2 RS232 Turn on the power of your host device.
  • Page 7 HID Mode Execute the Bluetooth Discovery procedure to find all available Bluetooth device list in your remote host. You will see ‘’CINO FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already. Double click the “CINO FxxxBT-xxxx” in the discovered Bluetooth device list.
  • Page 8: Establish Spp Master Connection

    Use FuzzyScan in SPP Mode Establish SPP Master Connection Ensure the battery is fully charged. Please go to the folder of “Hardware” located in Bluetooth Advanced Setting of the remote host device to check its device MAC address. Then prepare a 12-character Code 128 barcode of the remote host device MAC address, or follow the step 4 to input MAC address by scanning 12 option codes.
  • Page 9: Establish Spp Slave Connection

    SPP Slave Mode Execute the Bluetooth Discovery procedure to find all available Bluetooth device list in your remote host. You will see ‘’CINO FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already. Double click the “CINO FxxxBT-xxxx” on the discovered Bluetooth devices.
  • Page 10: Presentation Scanning

    Out-of-range Scanning When the radio is connected between the scanner and the remote host device, the scanner will transmit each scanned data right after scanning the barcode. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection with the remote host device. If you enable the out-of-range scanning function, the scanner is able to continue scanning barcode data while it is out of working range.
  • Page 11: Batch Scanning (Inventory Mode)

    Batch Scanning (Inventory Mode) Thanks to the specially designed Batch Scanning function, the scanner is capable of storing the barcode data up to 20,000 EAN-13 labels. It is an ideal cost-saving solution for inventory applications. Once you scan the “Enter Batch Scanning” command to activate this function, all scanned barcode data will be stored into the memory storage, and the status indicator of scanner will give green blink at regular interval during batch scanning.
  • Page 12 If you scanned a wrong barcode, the “Delete Last Scanned Data’’ command is helpful to recover mistake. By scanning the ‘’Delete Last Scanned Data’’ command, the last stored data can be deleted. Delete Last Scanned Data Use Quantity Feature If you want to use the quantity feature, please scan “Enable Quantity Field Transmission”...
  • Page 13: Host Interface Quick Set

    Link Mode Quick Set Uninstall SPP Master Mode PICO Mode PAIR Mode SPP Slave Mode HID Mode Host Interface Quick Set (Work with Smart Cradle only) RS232 Serial Keyboard Replacement PS/2 (DOS/V) KBW Standard Mode PS/2 (DOS/V) KBW Turbo Mode USB HID Standard Mode ◆...
  • Page 14: System Commands

    System Commands System Information Factory Default PowerTool Host Link Master Default Paging Save Configuration Sleep Clone Operation Mode Quick Set Trigger Mode ◆ Presentation Mode Option Codes FIN (Finish) END (Exit)
  • Page 15: Status Indicator

    Indications Link Indicator Status Indicator Descriptions Link Indicator Beeper Radio connected 1 blue blink per 2.5 sec. Radio disconnected 3 blue blinks per 2 sec. During connection Quick blue blinks Short clicks Radio connection built 1 blue blink per 2.5 sec. 4 beeps in ascending tone Radio connection lost 3 blue blinks per 2 sec.