Table of Contents Getting Started Getting Familiar with Your FuzzyScan Preparation before Using Decide Your Radio Link Mode Using FuzzyScan in PAIR Mode Using FuzzyScan in PICO Mode Using FuzzyScan in HID Mode Using FuzzyScan in SPP Mode Out-of-range Scanning/Presentation Scanning/Paging Function...
Getting Started Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Bluetooth Cordless Image Scanner. Powered by the combination of cutting-edge FuzzyScan 2.0 Imaging Technology and Bluetooth 2.1 EDR wireless technology, it not only provides outstanding reading performance, but also delivers the convenience and freedom of mobility. This document provides a quick reference for installation and operation purposes.
Getting Started Preparation before Using Install the Battery Ensure the battery co ntacts of the battery pack are facing the charging contacts inside the battery cavity. Slide the battery pack into the battery cavity until hearing a click sound before locking it with the end cap.
Decide Your Radio Link Mode The FuzzyScan Bluetooth image scanner provides several radio link modes to communicate with most host devices. When the Bluetooth-enabled host device is not available, it can work with the smart cradle in PAIR mode (one to one connection) or PICO mode (multiple connections) to provide a plug-and-play cordless migration of your existing non-Bluetooth-enabled IT assets.
The default host interface of smart cradle is preset to USB HID. If you want to set the host interface to USB COM, you have to install the USB virtual COM driver into your host device before using the scanner. Please visit the CINO website to download...
Getting Started Using FuzzyScan in PICO Mode Ensure the battery is fully charged and choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device. PS/2 RS232 Turn on the power of your host device.
Page 10
Getting Started Clone Function For the user’s convenience, the clone function will help you to clone the host interface related parameters (please refer to following table for details) from one of the paired scanners to the rest of paired scanners under PICO mode. You can use one of the paired scanners to set the host interface related parameters first and then scan “Save Configuration”...
FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already. Double click the “CINO FxxxBT-xxxx” in the discovered Bluetooth device list. If the PIN Code or Passkey is requested for security connection, please enter “00000000” (default setting). You will see “Keyboard on CINO FxxxBT-xxxx”, and double click this HID service to establish the connection between the scanner and the remote host device.
Getting Started Using FuzzyScan in SPP Mode Establish SPP Master Connection Ensure the battery is fully charged. Please go to the folder of “Hardware” located in Bluetooth Advanced Setting of the remote host device to check its device MAC address. Then prepare a 12-character Code 128 barcode of the remote host device MAC address, or follow the step 4 to input MAC address by scanning 12 option codes.
Page 13
‘’CINO FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already. Double click the “CINO FxxxBT-xxxx” on the discovered Bluetooth devices. If the PIN Code or Passkey is requested for security connection, please enter “00000000” (default setting). You will see “Serial Port on CINO FxxxBT-xxxx”, and double click this SPP service to establish the connection between the scanner and the remote host device.
Getting Started Out-of-range Scanning When the radio is connected between the scanner and the remote host device, the scanner will transmit each scanned data right after scanning the barcode. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection with the remote host device.
Getting Started Batch Scanning (Inventory Mode) Thanks to the specially designed Batch Scanning function, the scanner is capable of storing the barcode data up to 20,000 EAN-13 labels. It is an ideal cost-saving solution for inventory applications. Once you scan the “Enter Batch Scanning” command to activate this function, all scanned barcode data will be stored into the memory storage, and the status indicator of scanner will give green blink at regular interval during batch scanning.
Page 16
Transmission” command to enable this function. The preset delimiter is “ “ , but you are able to choose your desired one , , , , from FuzzyScan Wireless Reference Manual for details. Disable Quantity Field Transmission ◆ Enable Quantity Field Transmission...
You may scan more than one hundred programming families to meet any the desired family code and option code to set FuzzyScan. If specific requirements. you want to change the programming family for multiple...
You Before setting the FuzzyScan, please also refer to the need not re-program the FuzzyScan if you want to keep the “Beeping Indications” listed in Appendix to understand the existing configurations in the next power on.
Page 19
Please note that the FuzzyScan will take 3-4 seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the “END”. Please don’t turn off the power before the completion beeping.
Page 20
Configure Your FuzzyScan Single scan selection Single scan selection Single scan selection Single scan selection Multiple scans selection Multiple scans selection Multiple scans selection Multiple scans selection Scan Scan “PROGRAM” Enter programming mode. “PROGRAM” Enter programming mode. Select one of desired...
Page 21
Configure Your FuzzyScan Cycling scan selection Cycling scan selection Cycling scan selection Cycling scan selection Dual level selection Dual level selection Dual level selection Dual level selection Scan Scan “PROGRAM” Enter programming mode. “PROGRAM” Enter programming mode. Select one of desired...
Configure Your FuzzyScan Host Interface Selection PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code IBM PS/2, 25-30 series keyboard wedge interface Host Interface Selection Standard/TTL RS-232 peer-to-peer serial Wand emulation USB Com Port Emulation PS/2 (DOS/V) direct link (keyboard replacement)
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ User Defined Symbol ID ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Code 128 (default=B) (1 character) Symbol ID : 1 character...
Page 24
Symbology ID Transmission Enable prefix CINO symbology ID transmission Enable suffix CINO symbology ID transmission Enable both prefix and suffix CINO symbology ID transmission Enable prefix AIM symbology ID transmission Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission...
Page 25
China Postal Code German Postal Code Remember to scan “FIN” to terminate Code 93 * this selection. But if you select the Code 11 “ Auto ”, FuzzyScan will terminate this MSI/Plessey selection automatically. UK/Plessey Telepen GS1 DataBar (RSS-14) *...
Page 26
Trioptic Code 39 Setting Enable Trioptic Code 39 Default (01) Code 39 Min. Length 01-Maximum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Default (98) Code 39 Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Page 27
Disable check digit transmission Enable check digit transmission Default (04) Codabar Min. Length 01-Maximum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Default (98) Codabar Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Page 28
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ UPC-A & UPC-E Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable UPC-A UPC Family Setting Enable UPC-A Disable UPC-E Enable UPC-E Disable UPC-E expansion...
Page 29
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ UPC-A & UPC-E Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Select UPC without supplement digits UPC Supplement Setting Select UPC with only 2 supplement digits...
Page 31
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ UPC/EAN Security Level Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Level 0 UPC/EAN Security Level Level 1 Level 2 Only available for UPC-A & EAN-13...
Page 32
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ UCC Coupon Extended Code Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable UCC Coupon Extended Code UCC Coupon Extended Code Enable UCC Coupon Extended Code UCC Coupon Extended Code When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99”...
Page 33
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ IATA & Interleaved 2 of 5 Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable IATA IATA Setting Enable IATA Select 15-digit fixed length IATA checking...
Page 34
Enable check digit transmission Default (04) Code 25 Family Min. Length 01-Maximum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Default (98) Code 25 Family Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Page 35
Disable check digit transmission Enable check digit transmission Default (04) Code 11 Min. Length 01-Maximum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Default (98) Code 11 Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Page 36
Disable check digit transmission Enable check digit transmission Default (04) MSI/Plessey Min. Length 01-Maximum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Default (98) MSI/Plessey Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Page 37
ISBT Concatenation Off ISBT Concatenation On Default (01) Code 128/EAN-128 Min. Length 01-Maximum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Default (98) Code 128/EAN-128 Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Page 38
Disable check digit transmission Enable check digit transmission Default (04) UK/Plessey Min. Length 01-Maximum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Default (98) UK/Plessey Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Page 39
Disable check digit transmission Enable check digit transmission Default (04) Telepen Min. Length 01-Maximum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Default (98) Telepen Max. Length 98-Minimum (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Page 40
Default (04) GS1 DataBar Min. Length 01-Maximum (2 digits) Only available for Expanded GS1 Databar. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Default (74) GS1 DataBar Max. Length 74-Minimum (2 digits) Only available for Expanded GS1 Databar.
Page 41
Configure Your FuzzyScan Symbology Reading Control ♦ ♦ ♦ ♦ Linear-stacked & Korea Post Code Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable composite codes Composite Codes Setting Enable composite codes UPC Composite Mode: UPC never linked...
Configure Your FuzzyScan Keyboard Interface Control ♦ ♦ ♦ ♦ Keyboard Layout (Language) Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code USA (QWERTY) Keyboard Layout France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY)
Page 43
While selecting the other host interfaces, these selections don’t perform the above functions for you. Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then FuzzyScan will perform normal data transmission.
Page 44
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped;...
Page 45
Configure Your FuzzyScan Keyboard Interface Control ♦ ♦ ♦ ♦ Emulation Setting & Upper/Lower Case Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Enable ASCII 00-31 code as keyboard function code output Function Key Emulation Ctrl-Output Refer to Appendix –...
Configure Your FuzzyScan Serial Interface Control ♦ ♦ ♦ ♦ Record Suffix, Preamble ,Postamble Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable STX/ETX transmission STX/ETX Control Enable STX/ETX transmission STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
Page 47
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped;...
Page 48
This option is very helpful to ensure the reliability of data communication. When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK.
Configure Your FuzzyScan Wand/Laser Emulation Control ♦ ♦ ♦ ♦ Output Polarity, Signal State, Margin/Module Time, etc. ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code High level (5Vdc) on Bar (low level on Space) Output Polarity Low level (0Vdc) on Bar (high level on Space) Determine the output voltage level for both bar and space.
Configure Your FuzzyScan Operation Control ♦ ♦ ♦ ♦ Operation Mode ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Trigger mode Operation Mode Presentation mode Trigger Mode (Low Power Triggering) The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner before scanning the bar code.
Page 51
Configure Your FuzzyScan Operation Control ♦ ♦ ♦ ♦ Buzzer, Indicator, Vibrator, Inverse Reading, Dollar Sign ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Buzzer tone – mute Buzzer Tone Adjust Buzzer tone – low Buzzer tone –...
Page 52
The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted. The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification will not allow reading of the same bar code twice.
Page 53
Configure Your FuzzyScan Operation Control ♦ Time-out Setting, Good Read Beep Duration ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Short Light Source On Time Medium Long Extremely long Short Hands Free Time-out Medium Long Extremely long Disable...
Page 54
Configure Your FuzzyScan Operation Control ♦ ♦ ♦ ♦ Presentation Scanning Setting & Scan Rate Adjustment♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 3 mins SmartStand Power Off Timeout 5 mins 10 mins Only available for FuuzzyScan Laser model...
Page 55
Configure Your FuzzyScan Operation Control ♦ ♦ ♦ ♦ Out-of-range Scanning, Sleep Time-out Control ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable Out-of-range Scanning Enable 1 sec Link Supervision Time-out 3 secs 5 secs...
Page 56
Configure Your FuzzyScan Operation Control ♦ ♦ ♦ ♦ Batch Scanning Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Radio disable Batch Scanning Link Control Radio enable Stored Data Transmission On cradle Scan barcode...
Page 57
Configure Your FuzzyScan Operation Control ♦ ♦ ♦ ♦ Batch Scanning Data Transmission Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code None Field Delimiter , SPACE – . User define 5, [00-7F] As many times as the quantity indicates Batch Data Quantity Output Format <Quantity><Field Delimiter><Scanned Data>...
Page 58
Enable The default Bluetooth Device Name is “CINO FxxxBT-xxxx”, you will be able to change the device name by scanning HEX values (1-16 characters). The default Bluetooth PIN Code is “00000000”, you will be able to change the PIN Code by scanning HEX values (1-8 numbers).
Page 59
Configure Your FuzzyScan Operation Control ♦ ♦ ♦ ♦ Bluetooth Other Settings ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable HID Link Quality Setting Enable Disable Bluetooth Power Saving Mode Enable The HID Link Quality Setting While using the HID radio link mode, some errors may occur during the data transmission when the radio link is disconnected. You can enable this function to prevent such error from occurring.
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance.
Page 61
Configure Your FuzzyScan Condensed DataWizard ♦ ♦ ♦ ♦ Data Formatter Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Disable Formatter Control Select one bar code symbology automatic termination (2 digits)
Page 62
All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data.
Page 63
Configure Your FuzzyScan Condensed DataWizard ♦ ♦ ♦ ♦ Data Replacer Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Disable Replacer Control Select one bar code symbology automatic termination (2 digits)
Page 64
Configure Your FuzzyScan Condensed DataWizard ♦ ♦ ♦ ♦ Data Organizer Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Disable Organizer Control Select one bar code symbology automatic termination (2 digits)
Page 65
6-digit date code, 6-digit serial UPC-A : 02 EAN-8 with 5 supple.: 45 MSI/Plessey : 11 number and 4-digit unit price, you want the FuzzyScan do UPC-A with 2 supple.: 32 Codabar/NW-7 : 06 UK/Plessey : 12 UPC-A with 5 supple.: 42...
Page 66
Configure Your FuzzyScan Programming Procedure Programming Procedure Programming Procedure Programming Procedure [Data Verifier] [Data Replacer] Scan “Program” to enter the programming mode. Scan “Replacer Control” and set bar code symbology to “48”. Scan “Verifier Control” and set bar code symbology to “48”...
Appendix Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character c = Code Character m = Modifier Character Cino ID AIM ID Cino ID AIM ID Code Family Primary Format Code Family...
Appendix Keyboard Function Code Table ANSI ASCII Key Function ANSI ASCII Key Function RESERVED CTRL (Left) ALT (Left) SHIFT CAPS LOCK NUM LOCK INS (Insert) (Edit) DEL (Delete) (Edit) BACK SPACE HOME (Edit) END (Edit) PAGE UP (Edit) PAGE DOWN (Edit) UP (Edit) ENTER (CR) DOWN (Edit)
Appendix ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via HEX/ASCII Reference Table programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details.
Appendix Host Interface Quick Set (Work with Smart Cradle only) RS232 Serial PS/2 (DOS/V) KBW Standard Mode USB HID Standard Mode Keyboard Replacement PS/2 (DOS/V) KBW Turbo Mode USB HID Turbo Mode USB Com Port Emulation...
Appendix System Commands PROGRAM Save Configuration (Enter Programming Mode) Sleep FIN (Finish) Clone Paging Factory Default (Exit Programming Mode) PowerTool Host Link System Information List Master Default (SYSLIST) Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value (The radio link will be disconnected and the scanner will revert to uninstall state).
Appendix Indications Link Indicator Status Indicator Descriptions Link Indicator Beeper Radio connected 1 blue blink per 2.5 sec. Radio disconnected 3 blue blinks per 2 sec. During connection Quick blue blinks Short clicks Radio connection built 1 blue blink per 2.5 sec. 4 beeps in ascending tone Radio connection lost 3 blue blinks per 2 sec.
Page 75
Appendix Center Indicator Side Indicators HB2100 Charging Cradle Indication Descriptions Power Beeper Power on Steady blue HB2110 Smart Cradle Indications Indicators Descriptions Beeper Center Side Power on 1 blue blink Power on beeps Smart Cradle Upgrade State Steady red Short clicks Uninstall state Alternative red-green blinks Off Radio Connected...
Page 76
FuzzyScan Wireless Reference Manual CINO GROUP www.cino.com.tw PC WORTH INT’L CO., LTD.