1) 1 pattern
only. After completion of inversion pattern,
the pattern returns to the original one.
2) Continuous
operates the inversion pattern after the
inversion until thread trimming is performed
or, the mirror switch is pressed again.
* For the details, refer to "Mirror switch", p.95.

5 : Position of the stitch base line of condensation custom

The mode is the operation mode in terms of the stitch base line of condensation custom when the
reference of the stitch base line is set to that of center stitch base line.
For the condensation custom, there are two settings below.
1) Travelling together
custom and zigzag pattern together.
2) Fixed
: This is the mode that fixes condensation custom to the input data position.

6 : Counter function

ON
/ OFF
When OFF is set, even the counter display is not performed.

7 : Key lock

It is possible to lock the setting switch so that the zigzag width that has been set once or the contents
of custom pattern is not changed by mistake. However, it is possible to change ON/OFF of the reverse
feed stitch, thread trimming prohibiting switch, specified zigzag stop position and bobbin thread counter.
For the key lock, there are three kinds of settings below.
Level "0"
: All items can be changed.
Level "1"
:
is displayed on the right end of the screen.
Kind of sewing
Pattern : Change of pattern and registration
Custom : New creation and edit
Condensation custom : Edit
Continuous stitching : New creation, copy, deletion and edit
Cycle : New creation, copy, deletion and edit cannot be changed.
Level "2"
:
is displayed on the right end of the screen.
Items other than reverse feed stitching ON/OFF, thread trimming prohibition switch, specifying
zigzag stop position and bobbin thread counter cannot be changed.
Level of the standard delivery is "1". When changing the locked contents of level "1", it
Impor tant
is necessary to set the level to Level "0" once.

8 : Selection of max. zigzag width limitation display when the power is turned ON

Whether the max. zigzag width limitation value is displayed or not when the power is turned ON can be
selected.
Every time the setting switch is pressed, display/non-display is changed over alternately.
1) Display
2) Non-display
70
: Mirror inversion is "1" pattern
: The machine continuously
: This is the mode that travels the positions of stitch base line of condensation
of the function of thread trimming counter or bobbin thread counter is set.
Sewing direction
Pattern
mode
Continuous
mode
Mirror switch
LED lights up.
LED
lights up.
ON