Testing In Charge Mode And Ac Bypass Mode; Installation Complete - Xantrex Freedom SW 815-3012 Installation Manual

Freedom sw sine wave inverter/chargers
Hide thumbs Also See for Freedom SW 815-3012:
Table of Contents

Advertisement

Installing the Inverter/Charger
2.
After initialization, observe that none of the lights on the front panel
should remain illuminated.
3.
Press the Inverter Enable button. Verify that:
The Inverter Enable button light illuminates,
The Invert On light illuminates.
4.
Connect the Freedom SW to the test load by closing the AC breaker
that controls the circuit that the test load is connected to.
If the light bulb illuminates, the Invert mode is working.
5.
Press the Inverter Enable button to disable the inverter.
The Invert On light and Inverter Enable button light are off.
42

Testing in Charge Mode and AC Bypass Mode

1.
Close the AC supply breaker to supply AC power to the unit.
To verify that the Freedom SW starts charging:
2.
After a few seconds, verify that the AC/Charge light on the front panel
is turned on (indicating that the batteries are being charged).
To verify that Freedom SW correctly switches to Bypass mode:
3.
Disable the AC source and turn off the inverter by pressing the Inverter
Enable button.
4.
Connect the test load to the AC output connection of the unit.
5.
Enable the AC source and the test load should turn on after ten
seconds.

Installation Complete

Your installation is now complete. The inverter/charger is ready for use.
The preceding tests use a light test load (a light bulb) as a test case. If you
encounter problems when using a load over 1000 watts (for example, a hair
dryer or microwave), see the troubleshooting information in the Freedom
SW Sine Wave Inverter/Charger Owner's Guide.
Freedom SW Installation Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents