Weber MPE 750 Turbo Marine Service Manual page 30

Closed loop
Hide thumbs Also See for MPE 750 Turbo Marine:
Table of Contents

Advertisement

Service Manual
MPE 750 Turbo Marine
Closed Loop
Checking the valve play of the first cylinder
Desmontar la tapa de válvula
4)
Start the vehicle's starter and let
the engine crank until both cams
of the second cylinder are pointing
upwards.
The rocker of the first cylinder
demonstrates a little play.
5)
Using a feeler gauge, measure
the valve play (6) of all four valves
of the first cylinder between the
adjustment plates and the rockers.
Permissible valve play:
Intake side
0,08 - 0,15 mm
[0.0031 - 0.0059 in.]
Exhaust side
0,18 - 0,25 mm
[0.0071 - 0.0098 in.]
2nd cylinder
Drive side
5
6
103160_SHB_Rev2.1_080611