Weber MPE 750 Turbo Marine Service Manual page 17

Closed loop
Hide thumbs Also See for MPE 750 Turbo Marine:
Table of Contents

Advertisement

Service Manual
MPE 750 Turbo Marine
Closed Loop
Draining the motor oil (continuation)
The motor oil in the dry sump tank is pumped out with the help of the engine
dry sump pump.
5)
Remove the cable harness from
the spark plugs and the injection
valves. See Chapter Removing
the spark plugs.
6)
Remove the oil feed hose (2) on
one side of the oil tank. If necessary,
extend the oil feed hose.
Tightening torque:
3 Nm ± 10 % [2.2 ft. lb.]
7)
Activate the engine's starter every
10 seconds in order to let the engine
crank and wait 30 seconds.
8)
Repeat this procedure until the
motor oil is pumped completely
out.
ATTENTION
2
Do not let engine crank longer than necessary
to prevent damage due to insufficient lubrication
and overloading of the starter.
103160_SHB_Rev2.1_080611