Unpacking and installation

Important: Read instructions before filling the unit!
Unpacking
Place unit on its back. Remove cardboard box. Safety valve 3 bar is factory fitted to ø15 mm connection near the bottom.
Installation and pipe fitting
Place the unit upright and level. Use supplied adjustable feet. the 50 and 100 l. units are NOT fitted with adjustable feet, but
can be fitted to a wall, wall bracket is supplied. All pipe fitting and electrical connection must be done by authorized installer.
Connection dimensions: See table on previous page. An overflow pipe should be connected to the expansion valve.
Important: Fill the vessel with water before connecting electrical power (RE and RCE models). Otherwie the guarantee is void-
When filling water breathe the vessel through the ø22 connection on top of unit.

Electrical connection

All connection and service to the electrical components in this product (RE and RCE models) is to be performed by an autho-
rized electrician. All electric cables going into this product must be fitted with an approved cord ancorage. Always fill unit
with water before connecting the power supply.
Annual check-up
When the system is installed, check all connections for leaks. Repeat after approx. one week in service, then check annually.
The function of the safety valve must be checked annually by opening the valve to ensure water flows freely. Turn knob on
safety valve counterclockwise until water flows, continue counterclockwise until valve snaps shut.
Important: The safety valve outlet must never be plugged or blocked!
Electric service: Shut off power supply. Remove el. box lid and tighten all connections. Check electric cables for damage. Refit
el. box lid before power supply is turned on. If any damage to electrical components is discovered, contact approved electri-
cian and replace damaged parts with original spare parts.
Electrical connection
Standard from factory 230V - 3 ph.
All internal wiring is factory fitted. If necessary the power output can be reduced by removing jumper(s) in accordance
with the table below. All service to electrical components is to be performed by authorized electrician.
Selectable effect output
1
Factory fitted
Remove jumper 1
Remove jumper 1 + 2
Remove jumper 1 + 2 + 3
Power supply only to element 1
Remove jumper 1 230V 1-ph.
6
2
3
9,0 kW
15,0 kW
7,5 kW
12,5 kW
6,0 kW
10,0 kW
4,5 kW
7,5 kW
3,0 kW
5,0 kW
1,5 kW
2,5 kW