  • Page 1 SAFETY INFORMATION O&M INFORMATION INSTALLATION MANUAL TDS - TECHNICAL DATA SHEET Manufactured by OSO Hotwater AS Industriveien 1 - 3300 Hokksund - Norway Tel.: +47 32 25 00 00 / Fax: +47 32 25 00 90 E-mail: oso@oso.no / www.osohotwater.com...
  • Page 2: Table Of Contents

    CONTENTS 1. General information 8. Guarantee conditions 1.1 Product identification..........4 Guarantee ..............22 1.2 CE Marking.............4 8.1 Customer service ..........22 1.3 Erp Data..............4 1.4 General information ...........4 9. Removing the product 1.5 Handling..............5 9.1 Removal ..............22 1.6 Clearances..............5 9.2 Returns scheme ..........22 2.
  • Page 3 The product must have a clearance for servicing of 40 cm in front of the cover / over the mixer valve. This OSO product is approved to building and water regulations by KIWA Watertec Ltd. Tel: 01495 308 185 • Email: watertecenquiries@kiwa.co.uk...
  • Page 4: General Information

    1.1 Product Identification 1.4 General information Identification of your product can be found on the Thank-you for purchasing the OSO Slimline RI / label attached to the product. The label contains RD indirect / direct hot water cylinder. information about the product according to EN...
  • Page 5: Handling

    1.5 Handling, location and positioning The product should be transported carefully as shown, with packaging. Use the handles in the box. CAUTION Tappings, valves etc. should not be used to lift the product as this could cause malfunction. CAUTION The cylinder must be installed complying with current building regulations. The product should be placed in a dry and permanently frost-free position.
  • Page 6: Health And Safety Regulations

    The Regulations set no spe- mised. The OSO unvented unit is designed for use cific requirements such as weight limits. However with supply pressure up to 8 bar. For pressures...
  • Page 7 No. Description Part No. Return Boiler - 3/4” BSP Flow Boiler - 3/4” BSP Pressure Reducing Valve Multibloc (3 bar) 355030 includes Item 4 Expansion relief valve (6 bar) Temperature and Pressure Relief Valve 550853 Tundish 219005 Immersion heater (2 kW) 70628 Immersion heater thermostat 80020...
  • Page 8 be installed away from electrical devices. Boiler primaries - Primary flow & return and motorized valve 15. The boiler primary flow and return connec- tions should be made connections 1 & 2. The motorized valve can be connected to either the primary flow or return pipe.
  • Page 9: Piping Diagrams

    2.8 Piping diagrams S-plan piping diagram 2-port valve Zone valve (supplied) (not supplied) Radiators/ Automatic bypass Pump flow Boiler Y-plan piping diagram 2-port valve Mid pos. valve (supplied) (not supplied) Radiators/ Automatic bypass Pump flow Boiler...
  • Page 10: Commissioning And Installation

    3. COMMISSIONING & INSTALLATION 3.1 Filling up Open a hot tap. Open the cold water supply valve When water flows from hot tap, close the tap Allow the system to stabilize for 5 minutes Open each hot water tap in turn to expel air from the system pipe work.
  • Page 11: Electrical Installation

    (see the shoulders. fig.2 above). OSO Hotwater (UK) Limited can not be respon- 4.2 Immersion heaters sible if alternative wiring plans are used. All units are fitted with immersion heaters...
  • Page 12: S Plan Wiring Layout

    4.5 S-plan wiring layout Both wiring plans shown is based on the use OSO Slimline cylinders can be fitted with all types of a 10-way Junction Box (Honey-well Part no. of boilers. Standard boilers operate using room 42002116-001). Junction Box terminal 8 is switched and cylinder thermostats.
  • Page 13: Y Plan Wiring Layout

    4.6 Y-plan wiring layout zone valve. Failure to use the zone valve contra- OSO Slimline cylinders can be fitted with all types venes regulations. of boilers. Standard boilers operate using room Both wiring plans shown is based on the use and cylinder thermostats.
  • Page 14: Maintenance, Safety And Servicing

    Please note: OSO cylinders are not guar- If still out of operation, contact installer. anteed for use with a private water supply.
  • Page 15: Spare Parts

    5.5 Spare parts Pressure reducing valve Cartridge Part No. REDC 355030 - 3 bar Expansion valve (Cartridge and seat) Part No. 214005 6.0 Bar Expansion valve Part No. PREL 355030...
  • Page 16: Fault Finding Flow Charts

    5.6 Fault finding flow charts Intermittent water discharge Reduced expan- Thermal control sion volume failure Repressurize Switch off power to expansion vessel, immersion heaters see pt. 5.3 and boiler supply to the unit. When dis- charge has stopped check thermal con- trols and replace as necessary If problem stil persists contact a competent...
  • Page 17 Hot water from taps is cold Is the programm- Is the boiler er set to central working? heating or not switched on? Check and Is the mo- Has cylinder set to hot trized valve thermal water pro- operating cut-out gramme correctly? operated? Check wiring...
  • Page 18: Alternative Discharge & Secondary Return

    6. ALTERNATIVE DISCHARGE AND SECONDARY RETURN 6.1 Alternative discharge Downward discharges at low level, i.e. up to 100 plastics guttering system that would collect such discharges (tundish visible). Where a single pipe mm above external surfaces such as car parks, serves a number of discharges, such as in blocks hard standings, grassed areas etc, are accept- able pro-viding that where children may play or...
  • Page 19: Technical Specification Commisioning And Service Logbook

    IT IS THE RESPONSIBILITY OF THE INSTALLER TO COMPLETE THIS LOG BOOK AND PASS IT ON TO THE CUSTOMER. FAILURE TO DO SO MAY INVALIDATE THE CYLINDER GUARANTEE The code of practice for the installation, commissioning & servicing of mains pressure hot water storage Installation,Commissioning and Service Record Log Book CUSTOMER DETAILS...
  • Page 20 (IF APPLICABLE) COMMISSIONING ENGINEER (IF DIFFERENT) DATE NAME ADDRESS TEL No. REGISTRATION DETAILS REGISTERED OPERATIVE ID CARD No. (IF APPLICABLE) APPLIANCE & TIME CONTROL DETAILS MANUFACTURER OSO HOTWATER (UK) MODEL litres CAPACITY SERIAL No. TYPE UNVENTED TIME CONTROL PROGRAMMER TIME SWITCH IT IS THE RESPONSIBILITY OF THE INSTALLER TO COMPLETE THIS LOGBOOK AND PASS IT ON TO THE CUSTOMER.
  • Page 21 COMMISSIONING PROCEDURE INFORMATION BOILER PRIMARY SETTINGS (INDIRECT HEATING ONLY) ALL BOILERS IS THE PRIMARY A SEALED OR OPEN VENTED SYSTEM? SEALED OPEN WHAT IS THE BOILER FLOW TEMPERATURE? ALL MAINS PRESSURISED SYSTEMS WHAT IS INCOMING STATIC COLD WATER PRESSURE AT THE INLET TO THE PRESSURE REDUCING VALVE? HAS STRAINER (IF FITTED) BEEN CLEANED OF INSTALLATION DEBRIS? HAS A WATER SCALE REDUCER BEEN FITTED?
  • Page 22: Guarantee

    Products purchased by a consumer, that has been installed for installation. If the Product is not intended to be used for 60 private use and that has been distributed by OSO or by a distributor days or more, it must be drained.
  • Page 23: Service Interval Record

    SERVICE INTERVAL RECORD It is recommended that your hot water system is serviced regularly and that your service engineer completes the appropriate Service Interval Record below. SERVICE PROVIDER Before completing the appropriate Service Interval Record below, please ensure you have carried out the service as described in the manufacturer’s instructions and in compliance with all relevant codes of practice.
  • Page 24 OSO Hotwater (UK) Limited Endeavor House, Seventh Avenue, Team Valley Trading Estate, Gateshead, Tyne & Wear, NE11 0EF Phone: (0191) 482 0800 Fax: (0191) 491 3655 E-mail technical.uk@oso-hotwater.com E-mail spareparts.uk@oso-hotwater.com E-mail sales.uk@oso-hotwater.com OSO Hotwater AS Industriveien 1 3300 Hokksund - Norway Tel.: +47 32 25 00 00...

Table of Contents