3. INSTALLATION INSTRUCTIONS
3.1 Products covered by these instructions
800 0962
Saga Coil - SC 150
800 0963
Saga Coil - SC 200
800 0964 Saga Coil - SC 300
3.2 Included in delivery
Ref no.
Antall Beskrivelse
1
1
Insulated top cover (factory-fitted)
2
1
Mixer valve (factory-fitted)
3
2
Elbow brass for coil (included)
4
1
Tube for temperature sensor
5
1
Safety valve PT (factory-fitted)
6
1
Installation manual (this document)
7
1
Hot water heater with built-in coil
8
1
Thermostat
9
1
Heating element 3 kW 1x230V
10
1
Drain valve (factory-fitted)
11
3
Feet (factory-fitted)
3.3 Product dimensions
All dimensions in mm.
Product
A
B
SC 150
0-40
1010
SC 200
0-40
1260
SC 300
0-40
1710
Tolerance +/- 5 mm (not dimension A).
6
C
D
E
960
125
655
1210
125
655
1660
125
655
1
2
3
4
5
6
7
8
9
10
11
ø
570
570
570
B C
A
E
D
ø