Add Item:
To create the RS-232 item, complete the following settings and click the
Name
Perform Enabled Actions when
Send RS-232 String Action
RS-232 String (as Hexadecimal)
DTR (Data Terminal Read) Action
RTS (Ready To Send) Action
Configuration:
Configure the iCOMPEL RS-232 transmission to match the settings of the connected RS-232 equipment. To configure
RS-232, complete the following settings and click the
Bits per Second – Select the baud rate from 110 to 460800.
Data Bits – Select either 7 or 8 data bits.
Stop Bits – Select either 1 or 2 stop bits.
Parity – Select the parity as none, odd, or even.
Note: If your iCOMPEL is either a subscriber or publisher, it also displays the Local Override section. This allows you
to enable and define a local RS-232 configuration separate from the one defined in the channel.

9.3.5 Interactivity

Use the Interactivity page to program the iCOMPEL to respond to input from user-interaction devices.
Click the tab for the option you require:
Touch – Setting up and calibrating touch-sensitive screens.
RS-232 Inputs – Configuring and enabling responses to inputs through the RS-232 port.
Remote Keypad – Programming the actions associated with the buttons on the remote control.
Note: Some features may depend on installed feature keys.
Touch:
The Status field indicates the current state of the touch system:
No touch screen is connected.
Copyright © 2010-2013 Black Box Network Services. All Rights Reserved.
Enter a name to uniquely identify this RS-232 item.
Specify when the iCOMPEL executes the RS-232 item (in a playlist or automatically at
the event you specify).
Check the Send RS-232 String Action box to enable the iCOMPEL to send the RS-232
string you specify. Clearing the box disables it.
Enter the RS-232 string you want the iCOMPEL to send (in hexadecimal).
Check the Set DTR level box to enable the iCOMPEL to set the DTR line voltage to the
option you select. Clearing the box disables it.
Check the Set RTS level box to enable the iCOMPEL to set the RTS line voltage to the
option you select. Clearing the box disables it..