WARNING: Disconnect power before attempting any
maintenance to reduce the risk of electric shock or damage
to persons.
1. Unplug the unit from power outlet.
2. Remove the firebox from the front of the mantel and
remove front glass assembly (glass lifts off).
CAUTION: Even though the glass is safety glass it
may break if bumped, struck of dropped. Care must be
taken when handling the glass.
3. Remove the brick panels from either side of the unit,
they are attached using magnets.
4. Gently place the unit its back to expose the bottom
of the unit. Remove the 4 screws from bottom and 2
screw form either side that secure the logset.
5. Lift the logset out of the unit, being careful not to strain
the electronic cords.
6. Locate and remove the 2 brackets that hold the partially
reflective glass in the unit (along the bottom). (Figure 7)
7. Gently pry the glass forward using a flat head screw-
driver, being careful not to damage the corner tabs.
8. Transfer the rubber corner tabs from the old glass to
the new glass. Properly orient and install the new
glass.
9. Reassemble in the reverse order as above.