Axis Q1635 Installation Manual page 16

Axis q1635 network camera
Hide thumbs Also See for Q1635:
Table of Contents

Advertisement

AXIS Q1635 Network Camera
I/O connector
4–pin terminal block for:
• 0 V DC (-)
• Auxiliary power (DC output)
• Digital Input
• Digital Output
Function
Pin
1
0 V DC (-)
2
DC output
3–
Configurable
4
(Input or
Output)
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Digital input – Connect to pin 1 to activate,
or leave floating (unconnected) to deactivate.
Digital output – Connected to pin 1 when
activated, floating (unconnected) when
deactivated. If used with an inductive load,
e.g. a relay, a diode must be connected in
parallel with the load, for protection against
voltage transients.
1
2
3
4
16
Specifications
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open
drain, 100 mA

Advertisement

Table of Contents
loading

Table of Contents