Gas Pressure Regulator - Raypak 133 Installation & Operating Instructions Manual

Hot water supply heaters
Table of Contents

Advertisement

/ 1
" 2
N
0133
15
35
-
15
*0182/0181
-
10
*0260/0261
*0330/0331
*0400/0401
0
5
1
4
0
6
2
4
0
7
2
4
0
8
2
4
0926/0962
1083/1125
1178/1223
1287/1336
1414/1468
1571/1631
1758/1826
2100
2500
3001
3500
4001
* Models 0181, 0261, 0331, and 0401 are Low NOx units and are not available in propane.
A minimum of 7" WC and a maximum of 10.5" WC upstream pressure under load, and no load conditions must be provided for natural gas
or a minimum of 11" WC and a maximum of 13" for propane.
Pressure drops from the no load condition to the full load condition must be no more than 30% for proper operation.

Gas Pressure Regulator

The gas pressure regulator located in the gas valve is
preset nominally at 4" WC for natural gas, and 11" WC
for propane. Between the gas valve and the burners is
a 1/8" pipe plug. The pressure at this point, taken with
a manometer, should be about 3.7" WC natural gas
and 10.5" WC propane. Models 0181, 0261, 0331, and
0401 should be 3.9 WC natural gas. If an adjustment
is needed, turn adjustment screw clockwise to
increase pressure, or counter-clockwise to decrease
pressure.
Venting of Diaphragm Gas
Components
Gas train components that have diaphragms in their
construction are supplied with a bleed line connection
that must be connected to the outside atmosphere as
required by the National Fuel Gas Code. Under NO
circumstances shall bleed lines terminate in the gas
utilization equipment flue or exhaust system. Care
should be used to prevent obstruction to the bleed
lines, as blocked lines could prevent gas valves or
other devices from operating.
MAXIMUM EQUIVALENT PIPE LENGTH
NATURAL GAS 1000 BTU/Cubic Foot
PROPANE GAS 2500 BTU/Cubic Foot
3/4"
" 1
P
N
P
N
P
60
145
200
500
30
65
95
250
20
40
60
140
-
15
25
35
85
-
-
15
25
60
-
1
0
1
5
3
5
-
-
1
0
2
5
-
-
-
2
0
-
-
-
1
5
-
-
-
15
-
-
-
10
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Table G: Maximum Equivalent Pipe Lengths
.60 SPECIFIC GRAVITY @ 0.5" W.C. PRESSURE DROP
1.53 SPECIFIC GRAVITY @ 0.6" W.C. PRESSURE DROP
- 1
/ 1
" 4
1-1/2"
N
P
N
P
N
400
-
-
-
-
250
560
-
-
150
380
360
-
-
100
260
250
-
-
6
5
1
5
0
1
3
0
3
6
0
5
0
4
5
1
0
0
9
5
2
5
0
3
4
3
5
8
0
7
5
1
8
0
2
6
2
5
6
0
5
5
1
3
0
1
8
20
45
45
110
150
15
35
35
80
120
-
25
25
60
85
-
25
20
55
75
-
20
15
45
65
-
15
15
35
50
-
15
10
30
40
-
10
10
25
30
-
-
-
15
20
-
-
-
10
15
-
-
-
-
10
-
-
-
-
5
Fig. 20: Bleed Line Connection
21
2"
2-1/2"
3"
P
N
P
N
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0
-
-
-
-
0
-
-
-
-
0
6
0
0
-
-
-
5
4
8
0
5
0
0
-
-
360
400
-
-
300
300
-
-
220
200
-
-
180
170
325
560
150
165
300
500
120
125
250
400
100
100
225
340
80
75
175
260
55
55
135
160
35
40
85
120
30
30
45
80
20
25
35
65
4"
P
N
P
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
400
600
-
250
500
-
200
400
600
160
300
400

Hide quick links: