Configuration And Management; Safe Mode Messaging - Lexmark MS71x Study Manual

Hide thumbs Also See for MS71x:
Table of Contents

Advertisement

Lexmark MS71x/MS81x & MX71x/MX81x Product Study Guide

Configuration and Management

Category
POR Sequence
2.4" Control Panel
and
7 + 6 (letters S+M = Safe Mode)
Touchscreen
2-line Control Panel
STOP + BACK
LED models
(and all Control
NPA command
Panels)

Safe Mode Messaging

Category
Messaging
"The device is operating in Safe
2.4" Control Panel
Mode. Some print options may be
and
disabled or provide unexpected
Touchscreen
results."
2-Line APA Control
"Safe Mode"...
Panel
For Training Purposes Only
Description
 Safe Mode state will not disable on POR without holding
down the special button sequence.
 Safe Mode can co-exist with other POR button sequence
modes, such as Config and Diagnostics.
 Safe Mode can also be managed through the Config menu
via the Safe Mode menu. If the Safe Mode setting is
changed on this menu, the device must be PORed for the
new setting to take effect.
 An NPA command can be issued to enable Safe Mode.
 If the Safe Mode setting is changed via NPA command, the
device must be PORed for the new setting to take effect.
Description
 An intervention message will post at each POR once the
device is in Safe Mode.
 Priority 1 warning message will be displayed, toggling in
sequence with any other priority 1 warning messages, if
any are present.
 If the device is POR'ed into Diagnostics, Configuration or
SE menu, it will operate as if Safe Mode is disabled.
 A POR into any of these menus does not affect the Safe
Mode setting.
 An intervention message will post at each POR once the
device is in Safe Mode.
 A warning with custom message will appear and toggle
with any other warning messages.
89
Rev 1.3
11/19/2012

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents