Function Keys - DSC PowerSeries PC1616 Installation Manual

Version 4.2 na security system
Hide thumbs Also See for PowerSeries PC1616:
Table of Contents

Advertisement

[ ][6] – User Functions
Press [ ][6] followed by the Master Code, then press the number corresponding to the following functions.
[1]
Program Time and Date: Enter the time and date using the following format [HH:MM] [MM/DD/YY]. Program the time using
military standard (e.g., 8:00 pm = 20:00 hours).
[2]
Auto-arm/Auto-disarm Enable/Disable: The keypad will emit 3 rapid beeps if the Auto-arm/Auto-disarm feature is now enabled
and a steady 2-second tone if it is now disabled.
[3]
Auto-arm Time/Day: Press the number corresponding to the day of the week (1=Sunday, 2=Monday etc.) followed by the auto-
arm time (HH:MM). Program the time using military standard (e.g., 8:00 pm = 20:00 hours).
[4]
System Test: The panel will perform the following; activate the bell output, keypad buzzer and all keypad status lights for 2
seconds, test the backup battery and transmit a reporting code to the central station (if programmed).
[5]
Enable DLS: The panel will temporarily enable DLS for 1 or 6 hours depending on programming (see Sect [701] opt.[7]).
[6]
User Initiated DLS: The panel will attempt to call the DLS computer.
[7]
For Future Use
[8]
For Future Use
For LCD Keypads: Scroll to the desired option then press [ ]
Additional Alphanumeric Keypad Functions:
When scrolling through the list of available functions, the following additional functions are available:
Event Buffer:
Brightness Control:
Contrast Control:
Buzzer Control:
[ ][7][x] – Command Output (1-4)
Press [ ][7][x]. If the Command Output Code Required option is enabled, enter a valid user code. The panel will activate any PGM output
assigned to the command output.
[ ][8] – Installer Programming
Press [ ][8] followed by the Installer Code to enter Installer Programming. Refer to the 'How to Program' section for more information.
[ ][9][User Code] – No-Entry Arming
Press [ ][9] followed by a valid user code. The system will arm in the Stay mode and after the exit delay expires, it will remove entry delay.
All zones programmed as Delay will function like Instant zones. The system will flash the Armed light to indicate that the system is armed
with no entry delay.
[ ][0] – Quick Arm/Quick Exit
Quick Arm: When disarmed, press [ ][0] to arm the system. The system will arm as if a valid user code was entered.
Quick Exit: When armed, press [ ][0] to activate Quick Exit. The system will allow a single zone programmed as Delay to be violated once
during the following 2 minute time period without changing the status of the system.
Section 2.5 – Function Keys
Keypads have 5 programmable one-touch function buttons located in a column down the right-side of the keypad. These buttons can also be
activated by pressing and holding number [1] through [5] respectively for 2 seconds. The default for these function buttons on the PK series
keypads are as follows:
[1]
Stay Arm
[2]
Away Arm
[3]
Chime Enable/Disable
Used to view the 500-event panel buffer
Used to adjust the display backlighting level for optimal viewing
Used to adjust the display contrast level for optimal viewing
Used to adjust the keypad buzzer tone for optimal sound
[4]
[5]
WWW.DIYALARMFORUM.COM
Fire Reset – Command Output 2
Quick Exit
Section 2: User Commands
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerseries pc1832Powerseries pc1864Pc1808

Table of Contents