DSC PowerSeries PC1616 Installation Manual page 22

Version 4.2 na security system
Hide thumbs Also See for PowerSeries PC1616:
Table of Contents

Advertisement

PowerSeries - PC1616/PC1832/PC1864
Section [379] Periodic DLS Time of Day
Programs the time the system will auto-call DLS. Program 4 digits – [HH][MM] using military standard. For a DLS auto-call at 11:00 pm,
program data [23][00]). Valid entries are [00][00] to [23][59]. Programming [99][99] will select a random time, [FF][FF] will disable it.
Please refer to the PC 1616/1832/1864 Reference Manual for a complete description of Periodic DLS.
Section [380] First Communicator Option Code
Option
Description
[1]
ON: the system communicator is enabled. OFF: the communicator is disabled.
[2]
ON: the system transmits alarm restorals if the zone is restored and the bell has timed out. OFF: the system transmits alarm restorals
immediately when the zone is restored.
[3]
ON: the panel uses rotary (pulse) dialing. OFF: the panel uses touchtone (DTMF) dialing
[4]
ON: the panel will switch from touchtone dialing to rotary dialing after the 4th failed attempt to communicate.
OFF: the panel will use DTMF dialing for all dialing attempts.
[5]
ON: the system uses the Third Phone Number to back up the First Phone Number. OFF: the Third Phone Number is disabled.
[6]
ON: the system alternates between the First Phone Number and Third Phone Number when attempting to report an event.
OFF: the panel will dial the First Phone Number for the programmed number of attempts, then switch to the Third Phone Number.
[7]
For future Use
[8]
ON: the Delinquency feature follows zone activity. OFF: the Delinquency feature follows arming.
Section [381] Second Communicator Option Code
Option
Description
[1]
ON: the keypad beeps 8 times after successfully transmitting the Opening After Alarm reporting event. OFF: the keypad does not beep.
[2]
ON: the bell output squawks 8 times after successfully transmitting the Opening After Alarm reporting event. OFF: the bell output does
not activate.
[3]
ON: the system uses programmed reporting codes when transmitting using the SIA format.
OFF: the system automatically generates all reporting codes transmitted.
[4]
ON: the system beeps the keypad 8 times after successfully transmitting a Closing reporting event. OFF: the keypad does not beep.
[5]
ON: the system requests a Listen in/Two-way session the next time it calls the 1st/3rd Phone Number when the PC59xx transmits a
request. OFF: the system ignores the request from the PC59xx.
This Option is used with PC59xx series modules.
[6]
ON: the system requests a Listen in/Two-way session the next time it calls the 2nd Phone Number when the PC59xx transmits a request.
OFF: the system will ignore the request from the PC59xx.
This Option is used with PC59xx series modules.
[7]
ON: the system uses Contact ID format programmed reporting codes when transmitting reporting codes.
OFF: the system automatically generates all reporting codes transmitted.
[8]
ON: the system will follow ULC Communication Priority OFF: the system will follow standard communications priority.
Section [382] Third Communicator Option Code
Option
Description
[1]
ON: the system will use the digit [5] as the first digit of the Partial Closing reporting code when transmitting Contact ID reporting codes.
OFF: the system will use the digit [4] as the first digit of the Partial Closing reporting code when transmitting Contact ID reporting codes.
[2]
ON: the system will transmit all alarms during Walk Test. OFF: the system will not report alarm events during Walk Test.
20
WWW.DIYALARMFORUM.COM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerseries pc1832Powerseries pc1864Pc1808

Table of Contents