Aux Power Wiring; Pgm Wiring; Telephone Line Wiring; Ground - DSC PowerSeries PC1616 Installation Manual

Version 4.2 na security system
Hide thumbs Also See for PowerSeries PC1616:
Table of Contents

Advertisement

PowerSeries - PC1616/PC1832/PC1864

1.5 AUX Power Wiring

The control panel can provide a maximum of 700mA of current for modules, powered detectors, relays, LED's etc. If the total
current required exceeds 700mA an additional power supply is required (e.g.,PC5200, PC5204). See list below.
Min/max operating voltages for devices, sensors and modules is 9.5V
Refer to the list of Compatible Devices on page 1 and/or the Reference Manual for the current draw of individual devices

1.6 PGM Wiring

PGMs switch to ground when activated by control panel.
Connect the positive side of the device to be activated to the AUX+
Terminal. Connect the negative terminal to the PGM.
current output is as follows
• PGM 1, 3, 4............................................................................... 50mA
• PGM 2..................................................................................... 300mA
2-wire Smoke Detectors Initiating Circuit
• Style B (Class B), Supervised, Power Limited
• UL Compatibility Identifier .................................................... PC18-1
• DC Output Voltage........................................................9.8-13.8 VDC
• Detector Load ............................................................... 2mA (MAX)
• Single-end-of-line (SEOL) Resistor ........................................ 2200Ω
• Loop Resistance.............................................................. 24Ω (MAX)
• Standby Impedance..................................................... 1020Ω (ΝΟΜ)
• Alarm Impedance.......................................................... 570Ω (MAX)
• Alarm Current .............................................................. 89mA (MAX)
UL Compatibility ID For FSA-210B Series is: FS200
NOTE: For ULC Listed installations use FSA-210A and FSA-410A series

1.7 Telephone Line Wiring

Wire the telephone connection terminals (TIP, Ring, T-1, R-1) to an RJ-
31x Connector as indicated. Use 26 AWG wire minimum for wiring.
For connection of multiple devices to the telephone line, wire in the
sequence indicated.
Telephone format is programmed in section [350].
Telephone Call Directions are programmed in section [351]-[376].

1.8 Ground

Ground Installation
Tighten nut to break paint and make
good connection to the cabinet
NOTE: Do not connect transformer to a receptacle controlled by a switch. (UL Listed Installations Only)
4

1.9 Battery

A sealed, rechargeable, lead acid
battery or gel type battery is required
to meet UL requirements for power
standby times.
NOTE: UL Residential/Commercial
Burglary installations require
4Hrs Power Standby time.
NOTE: UL/ULC Residential Fire &
Health Care installations require 24
Hr. power standby. ULC Commercial
Burglary and Fire monitoring installa-
tions require 24 Hr. power standby.
WWW.DIYALARMFORUM.COM
DC
For currents levels greater than 300mA a relay is
required. PGM2 can also be used for 2-wire smoke
detectors.
NOTE: Use SEOL resistors on Fire Zones ONLY.
PGM 1, LED output with current limiting resistor and
Optional Relay driver output
4-wire Smoke Detectors
RM-1/RM-2 POWER LOOP
SUPERVISORY RELAY
T-1
R-1
TIP
RING
RJ-31X
Standby Battery Guide
Battery Charging Current: 400 mA
Batt
Standby
Size
4Hr
24Hr
-------------------------------------------------
4Ahr
700mA
----
7Ahr
700mA
180mA
14Ahr
700mA
470mA
NOTE:
Battery capacity will deteriorate with
age and number of charge/discharge
cycles. Replace every 3-5 years.
- 14V
DC

1.10 AC Wiring

AC Wiring
UL Listed
Installations
Primary: 120VAC/
60Hz./0.33A
Secondary:
16.5VAC/40VA
DSC PTD 1640U
Plug-in, Class 2
Transformer.
Use DSC PTD 1640U
for Canadian Installa-
tions

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerseries pc1832Powerseries pc1864Pc1808

Table of Contents