Aeris A300 CS Operating Manual page 58

Dive computer
Table of Contents

Advertisement

battery.Indication:
• Good (> 2.75 v) >> BATT Icon (green) solid on Surface and Dive Mains. No restrictions surface or dive..
• Warning (<= 2.75 v) >> BATT Icon (yellow) solid on Surface and Dive Mains, Battery change recommended. Brightness level automatically limited to
60% maximum.
• Alarm (<= 2.50 v) >> BATT Icon (red) flashing on Surface and Dive Mains. Graphics GO UP LOW BATTERY with Up Arrows flashing on Dive Mains,
graphics CHANGE BATTERY (red) flashing on Surface Mains until the unit the shuts off. Must change the Battery.
Transmitter.battery.Indication:
• Warning (<= 2.75 v) >> graphic BATT LOW (yellow) solid on BATT, TMT STATUS screen, Battery change recommended.
• Alarm (<= 2.50 v) >> graphic TMTx LOW BATTERY (red) alternating with graphic NORM (or GAUG, or FREE) on Surface Main. Change the Battery.
• Alarm (<= 2.50 v) >> graphic BATT LOW (red) flashing on BATT, TMT STATUS screen. Change the Battery.
Operating.Temperature:
• Out of the water >> between 20 °F and 140 °F (-6 and 60 °C).
• In the water >> between 28 °F and 95 °F (-2 and 35 °C).
bAR.GRAPHS:
TLbG
segments
• No Deco Normal zone
1 to 6 (green)
• No Deco Caution zone
7 to 9 (yellow)
• Decompression zone
10 (red)
VARI
60 FT (18 M) & Shallower
segments
0
• Normal zone (green)
1
Normal zone (green)
2
Normal zone (green)
3
• Caution zone (yellow)
4
• Too Fast zone (red)
5 (all flash)
NUMERIC.DISPLAYS:.
• Time of Day
• PC/Mac Countdown Timer
• Altitude Level
• Time to Fly
• Time to Desaturate
• Temperature
• Depth, Max Depth (display)
• Tank Pressure
• NORM, GAUG Surface Interval
• NORM, GAUG Dive Number
• NORM, GAUG Log Entry Number
• NORM, GAUG Elapsed Dive Time
• NORM Dive Time Remaining
• NORM, GAUG Air Time Remaining
• FO2 Set Point (Gas 1, 2, 3, 4)
• PO2 (current value)
• O2 Saturation
• No Deco Deep Stop Time
• No Deco Safety Stop Time
• No Deco Safety Stop Run Timer
• GAUG Dive Run Timer
• Deco Stop Time
• Deco Total Ascent Time
• Violation Countdown Timer
© 2002 Design, 2014
SPECIfICATIONS (CONTINUED)
.
Deeper than 60 FT (18 M)
FPM
MPM
segments
0 - 10
0 - 3
0
11 - 15
3.5 - 4.5
1
16 - 20
5 - 6
2
21 - 25
6.5 - 7.5
3
26 - 30
8 - 9
4
> 30
> 9
5 (all flash) > 60
Range:
0:00 to 23:59 hr:min
2:00 to 0:00 min:sec
Sea, EL-2 to EL-7
23:50 to 0:00 hr:min
23:50 to 0:00 hr:min
0 to 99°F (-18 to 60°C)
0 to 330 FT (100 M)
0 to 5000 PSI (345 BAR)
0:00 to 23:59 hr:min
0 to 24
0 to 99
0:00 to 9:59 hr:min
0:00 to 9:59 hr:min
0 to 99 min
Air, 21 to 100 %
0.00 to 5.00 ATA
0 to 100 %
2:00 to 0:00 min:sec
5:00 to 0:00 min:sec
0:00 to 9:59 min:sec
0:00 to 9:59 min:sec
0:10 to 9:59 hr:min
0:00 to 9:59 hr:min
0:00 to 9:59 hr:min
23:50 to 0:00 hr:min
FPM
MPM
0 - 20
0 - 6
21 - 30
6.5 - 9
31 - 40
9.5 - 12
41 - 50
12.5 - 15
51 - 60
15.5 - 18
> 18
Resolution:
1 minute
1 second
1 (level)
1 minute
1 minute
1°F (C)
1 FT (0.1 M )
5 PSI (1 BAR)
1 minute
1 (dive)
1 (dive)
1 minute
1 minute
1 minute
1 %
.01 ATA
1 %
1 second
1 second
1 second
1 second
1 minute
1 minute
1 minute
1 minute
58
A300 CS OPERATING MANUAL
Doc. No. 12-7287-r03 (7/14/14)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents