Set.alarms.menu; Set.utilities.menu; Set.preview - Aeris A300 CS Operating Manual

Dive computer
Table of Contents

Advertisement

SET ALARMS MENU (NORM), information includes (Fig. 30):
Selections with their last Set points saved include:
> AUDIBLE = with ON or OFF.
> DEPTH = with OFF, or 30 to 330 FT (or 10 to 100 M), increments of 10 FT (3 M).
> EDT = with OFF, or 0:10 to 3:00 (hr:min), increments of :05. EDT is Elapsed Dive Time.
> TLBG = with 1 to 8 SEG, increments of 1 SEG. SEG means Segments of the bar graph
> DTR = with OFF, or 1 to 0:20 ( :min), increments of :01. DTR is Dive Time Remaining.
> TURN = with OFF, or 1000 to 3000 PSI (or 70 to 205 BAR), increments of 250 PSI (5 BAR). TURN is pressure of TMT 1.
> END = with 300 to 1500 PSI (or 20 to 105 BAR), increments of 100 PSI (5 BAR). END is pressure of the TMT in use.
• A (< 2 sec) - to step forward (down screen) through and highlight Menu selections.
• M (< 2 sec) - to step back (up screen) through Menu selections.
• S (< 2 sec), when a selection is highlighted - to highlight & flash that item's set point.
• A (< 2 sec) - to toggle or increase the set point.
• A (hold) - to increase the set point at a rate of 8 per second.
• M (< 2 sec) - to toggle or decrease the set point.
• S (< 2 sec) - to save the setting and revert to the Set Alarms Menu.
SET UTILITIES MENU (NORM), information includes (Fig. 31A):
Selections with their last Set points saved include:
> WATER = with FRESH or SEA. This adjusts depth values based on the type of water .
> UNITS = with IMPERIAL or METRIC.
> DEEP STOP = with OFF or ON. This only applies to No Deco dives .
> SAFE STOP = with OFF, ON, or TIMER. This only applies to No Deco dives .
> ALGORITHM = with DSAT or Z+. This determines the basis for Ni-O2 calculations .
> CONSERV = with OFF or ON. This, Conservative Factor, reduces NDLs based on altitude level .
> SAMPLING = with 2, 15, 30, or 60 SEC (second). This is the rate that data is sampoled and recorded for PC download .
Additional information relating to the effects of the items included are described in associated sections throughout this manual.
• A (< 2 sec) - to step forward (down screen) through and highlight Menu selections.
• M (< 2 sec) - to step back (up screen) through Menu selections.
• S (< 2 sec), when a selection is highlighted - to highlight & flash that item's set point.
• A (< 2 sec) - to toggle or increase the set point.
• A (hold) - to increase the set point at a rate of 8 per second.
• M (< 2 sec) - to toggle or decrease the set point.
• S (< 2 sec) - to save the setting and revert to the Set Utilities Menu.
Set Safety Stop
In addition to OFF, ON, and TIMER; Safe Stop has a SET selection .
• S (< 2 sec), while SET is flashing - will display the Set Safe Stop Time/Depth screen with the Time setting flashing (Fig. 31B).
• A or M (< 2 sec) - to toggle TIME between 3 MIN and 5 MIN.
• S (< 2 sec) - to save the Time setting and flash the Depth digits.
• A (< 2 sec) - to step upward through Depth set points of 10, 15, 20 FT (or 3, 4, 5, 6 M).
• M (< 2 sec) - to step back through Depth set points.
• S (< 2 sec) - to save the setting and revert to the Set Utilities Menu with SET highlighted & flashing allowing OFF, ON, or
TIMER to be selected/saved (as described above).
SET PREVIEW (NORM), information includes (Fig. 32):
Using this listing, you can chose up to 7 items (set points that have been entered) for display on a Preview screen that can be ac-
cessed from the NORM Menu (see page 16).
> FO2, PO2 alarms set for - Gas 1, 2, 3, 4.
> Alarm values set for - Depth, EDT, DTR, TLBG, Turn Pressure, End Pressure.
> Water Type selected .
> Deep Stop seting .
> Safety Stop setting .
• A (< 2 sec) - to step forward (down 1st column then 2nd) through & highlight selections.
• M (< 2 sec) - to step back (up) through selections.
• S (< 2 sec) - when an item is highlighted will toggle* it between solid and flashing.
*Once 7 items are highlighted/flashing, another item cannot be toggled to be highlighted/flashing until one of the
highlighted/flashing items is toggled to solid, not highlighted first.
When satisfied that those items flashing (up to 4) are what you want for the Preview screen, press S (2 sec) to display all
items flashing, then press S (< 2 sec) to revert to the Menu with SET PREVIEW highlighted.
© 2002 Design, 2014
20
A300 CS OPERATING MANUAL
NORM SET ALARMS
AUD I B L E =
O N
DE P T H =
1 3 0 F T
E DT =
0 : 4 0
T L B G =
8 S E G
DT R =
0 : 1 0
1 5 0 0 P S I
TU RN =
E ND =
3 0 0 P S I
Fig. 30 - SET ALARMS
NORM SET UTILITIES
WAT ER =
F R ES H
U NI TS =
I M P E RI A L
D E E P S TO P =
O F F
S AF E S TO P =
TI M E R
ALGO R I T H M =
D S AT
CO N S E RV =
O N
S AM P L I N G =
1 5 S EC
Fig. 31A - SET UTILITIES
SET SAFE STOP
T I M E =
3 M I N
D EP TH = 1 5 F T
Fig. 31B - SET NO DECO
SAFETY STOP
NORM SET PREVIEW
1
GAS
T L B G A L
2
GAS
WAT ER
GAS
3
D E EP S TO P
4
GAS
S A F E S TO P
D E P TH A L
TUR N A L
E DT A L
E ND A L
DT R A L
Fig. 32 - SET PREVIEW
Doc. No. 12-7287-r03 (7/14/14)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents