Aeris A300 CS Operating Manual page 50

Dive computer
Table of Contents

Advertisement

AIR TIME REMAINING (ATR) ALARM (at 0 min) (Fig. A9)
Audible >> sounds until acknowledged or time out (10 sec), or ATR => 1 min.
ATR digits & icon >> flash (red) until the Audible is silenced, then the digits flash (yellow) until ATR > 5 min, then return to
solid (normal color, green) .
LOST LINK WITH TRANSMITTER (TMT in use) (Fig. A10)
Activate >> TMT signal interrupted for 15 sec.
Audible >> sounds until acknowledged or time out (10 sec).
Pressure digits & PSI (or BAR) icon >> flash (normal color) until the Link is regained, or time out of 8.5 minutes after
surfacing*. At 1 minute, the last Pressure reading will be - - - - PSI ( - - . - BAR).
*Pressure < 50 PSI (3.4 BAR) will be displayed as - - - - PSI ( - - . - BAR) for 2 minutes, then the TMT will shut down.
-----------------------------------------------------------------------------------------------------------------
LOW BATTERY WARNING & ALARM - refer to page 8.
DECO & VIOLATIONS - refer to pages 28 to 30.
HIGH PO2 WARNINGS & ALARMS - refer to page 30.
HIGH O2 WARNINGS & ALARMS - refer to page 31.
fREE DIVE WARNINGS & ALARMS - refer to page 41.
COMPASS MODE WARNINGS & ALARMS - refer to page 47.
© 2002 Design, 2014
50
A300 CS OPERATING MANUAL
27
BATT
FT
NDC
0:23
GAS 1
ATR
360
TL
PSI
Fig. A9 - ATR WARNING
35
BATT
FT
NDC
1:29
GAS 1
ATR
2830
83
TL
PSI
Fig. A10 - LOST LINK
Doc. No. 12-7287-r03 (7/14/14)
AR
0
AR

Hide quick links:

Advertisement