NO DECO MAIN, information includes** (Fig. 40A/B):
> BATT icon - green (if battery voltage is good), or yellow (if at warning level), or red (if at alarm level).
> Current Depth with FT (or M) icon.
> Dive Time Remaining (hr:min) with NDC (or OTR) icon.
> Graphic GAS 1 (or 2, 3, 4), one in use.
> Pressure with PSI (or BAR) icon, if the Receiver and Transmitter are active, flashing when Link is lost; or graphic SPG when
no Transmitter is in use (SPG = Submersible Pressure Gauge).
> Air Time Remaining (min) with icon, up to 99 (remains at 99 when greater), blank if SPG.
> DS icon - if Deep Stop is set ON and has triggered (activated).
> TLBG (TL), VARI (AR) - if they apply.
• A (2 sec) - to access Adjust Brightness.
• A (< 2 sec) - to access ALT.
• M (2 sec) - to access the Gas/TMT Switch Menu*.
• M (< 2 sec) - to apply a snapshot Earmark to the PCI data recorded at that time. The graphics EARMARK APPLIED will be
displayed in place of NDC for 3 seconds (Fig. 40C).
• S (< 2 sec) - to restore screen Brightness from the Auto Dim level to the % level you last adjusted it to.
• S (< 2 sec) - to acknowledge alarms; this will also restore screen Brightness if it was dimmed by Auto Dim.
• S (2 sec) - to access Compass*.
ADJUST BRIGHTNESS, information includes (Fig. 41):
> xx % (last value saved). Up to 60% max when Low Battery Warning or Alarm.
• S (2 sec) - to step back to the Main without changing the value.
• A (< 2 sec) - to step upward through values of 10% to 100% one at a time in increments of 10%.
• M (< 2 sec) - to step down through values one at a time.
• S (< 2 sec) - to save the % setting and revert to the Main.
• Revert to Main in 10 sec, if no button is pressed.
NO DECO ALT, information includes (Fig. 42):
> NDC = hr:min (up to 9:59).
> EDT = hr:min (up to 9:59).
> MAX D = xxx FT (or xx.x M).
> TIME = hr:min with AM (or PM) if 12 Hour Format.
> TEMP = xx F (or C).
> GAS 1 (or 2, 3, 4) = AIR; or FO2 % set with PO2 Alarm setting.
> PO2 = x.xx (current level).
> O2 SAT = xx % (current level of saturation).
• A (< 2 sec) - to access DS Preview if On and triggered, or revert to Main.
• M (< 2 sec) - to step back to Main.
• Revert to Main in 10 sec, if no button is pressed.
DEEP STOP (DS) PREVIEW (if On and triggered), information includes (Fig. 43):
> Current Depth with FT (or M) icon.
> Graphic DEEP STOP with Stop icon (arrows and bar).
> Stop Depth with FT (or M) icon and countdown Time as 2:00 (min:sec).
• A (< 2 sec) - to revert to Main.
• M (< 2 sec) - to step back to ALT.
• Revert to Main in 10 sec, if no button is pressed.
DEEP STOP (DS) MAIN, information includes (Fig. 44A):
> BATT icon - green (if battery voltage is good), or yellow (if at warning level), or red (if at alarm level).
> Current Depth with FT (or M) icon.
> Graphic DEEP STOP with Stop icon (arrows and bar).
> Stop Depth with FT (or M) icon and countdown Time (min:sec).
> Graphic GAS 1 (or 2, 3, 4), one in use.
> Pressure with PSI (or BAR) icon, if the Receiver and Transmitter are active, flashing when Link is lost; or graphic SPG.
> Air Time Remaining (min) with icon, up to 99 (remains at 99 when greater), blank if SPG.
> TLBG (TL), VARI (AR) - if they apply.
• A (2 sec) - to access Adjust Brightness.
• A (< 2 sec) - to access DS ALT (similar to No Deco ALT).
• M (2 sec) - to access the Gas/TMT Switch Menu*.
• M (< 2 sec) - to apply a snapshot Earmark to the PCI data recorded at that time. The graphics EARMARK APPLIED will be
displayed in place of Stop information for 3 seconds (Fig. 44B).
• S (< 2 sec) - to restore screen Brightness from the Auto Dim level to the % level you last adjusted it to.
• S (< 2 sec) - to acknowledge alarms; this will also restore screen Brightness if it was dimmed by Auto Dim.
• S (2 sec) - to access Compass*.
© 2002 Design, 2014
*These items can only be accessed while viewing the Main.
*These items can only be accessed while viewing the Main.
27
A300 CS OPERATING MANUAL
86
BATT
FT
NDC
0:24
DS
GAS 1
ATR
1480
42
TL
PSI
Fig. 40A - NO DECO MAIN
(FO2 set for Nitrox)
95
BATT
F F T
NDC
0:38
GAS 1
SPG
TL
Fig. 40B - NO DECO MAIN
(no Transmitters in use)
86
BATT
FT
E A R M A R K
A P P L I E D
GAS 1
ATR
1480
42
TL
PSI
Fig. 40C - NO DECO MAIN
(during 3 sec message)
ADJUST BRIGHTNESS
1 0 0 %
Fig. 41 - BRIGHTNESS
ND C =
0 :1 6
EDT =
0 : 4 2
MAX D =
1 2 3 F T
TI M E =
3 :4 1 PM
T EM P =
7 3 F
G A S 1 =
3 2 %, 1 .4 0
2
0 .6 4
P O
=
2
O
S AT =
3 8 %
Fig. 42 - NO DECO ALT
98
FT
D E E P STO P
56
2:00
FT
Fig. 43 - DS PREVIEW
47
BATT
F
FT
D E E P S TO P
46
1:38
FT
GAS 1
ATR
1750
23
TL
PSI
Fig. 44A - DS MAIN
47
BATT
FT
F
E A R M A R K
A P P L I E D
GAS 1
ATR
1750
23
TL
PSI
Fig. 44B - DS MAIN
(during 3 sec message)
Doc. No. 12-7287-r03 (7/14/14)