Specifications - Aeris A300 CS Operating Manual

Dive computer
Table of Contents

Advertisement

CAN.bE.USED.AS
• Dive Computer (Air or Nitrox) with up to 4 Gases up to 100% O2 and 4 Transmitters.
• Digital Depth Gauge/Timer with up to 4 Transmitters.
• Free Dive (breath hold) activity with Depth Gauge, Countdown Timer.
• Compass.
DIVE.COMPUTER.PERFORMANCE
• Buhlmann ZHL-16c based Pelagic Z+, or DSAT based, algorithm.
• No Deco limits closely follow PADI RDP.
• Decompression in agreement with Buhlmann ZHL-16c and French MN90.
• No Deco Deep Stops >> Morroni, Bennett.
• Deco Deep Stops (not recommended) >> Blatteau, Gerth, Gutvik.
• Altitude >> Buhlmann, IANTD, RDP (Cross).
• Altitude corrections and O2 limits based on NOAA tables.
TRANSMITTERS.(TMTs)
• Battery and Pressure check
>>
every 2 seconds when awake
• Startup
>>
Pressure => 120 PSI (8 BAR)
>>
Battery => 2.75 volts
• Shutdown
>>
Pressure < 50 PSI (3.5 BAR)
TMT.Compatibility.with.Nitrox
• When packaged and shipped from the factory, AERIS Transmitters are rated for use with compressed Air and Nitrox mixtures containing up to 99% O2
by volume and with 100% O2.
OPERATIONAL.PERFORMANCE
Function:
Accuracy:
• Depth
±1% of full scale
• Timers
1 second per day
Activation:
• Manual activation by pressing any button.
• Cannot be manually activated deeper than 4 FT (1.2 M).
• Will not operate at elevations higher than 14,000 feet (4,270 meters).
• Automatic activation of Dive Mode by wet activation contacts upon descent to 5 FT (1.5 M) for 5 seconds.
Unit.Shutoff:
• 2 hours after activation, if no dive conducted.
• 24 hours after conducting a dive, if no further dives conducted.
Dive.Counter:
• NORM & GAUG modes display Dives #1 to 24, FREE mode displays #1 to 99 (0 if no dive made yet).
• Resets to Dive #1 upon diving after 24 hours with no dives.
Dive.Log.Mode:
• Stores 24 most recent NORM & GAUG dives in memory for viewing.
• After 24 dives, adds 25th dive in memory and deletes the older dive.
Altitude:
• Operational from sea level to 14,000 feet (4,270 meters) elevation.
• Measures ambient pressure upon activation and every 15 minutes while in Surface modes.
• Does not measure ambient pressure when Wet.
• Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.
Power.Supply:
• A300 CS Battery
(1) 3 vdc, CR2, 800 mAh, Lithium battery (Duracell, Energizer, Panasonic, or RayOvac recommended)
• Use Life
15 operating hours at 100% brightness with Auto Dim set Off
• Transmitter Battery
(1) 3 vdc, CR2, .75 Ahr, Lithium battery (Duracell or equivalent)
• Use Life
300 dive hours if (2) 1 hour dives per dive day
• Shelf life
Up to 5 years
• Replacement
User replaceable (annual recommended)
Power.Saver.Mode.(surface):
• Activates and turns screen off when 2 minutes elapse on surface with no button operations.
• Resume operation from Power Saver Mode by pressing any button.
© 2002 Design, 2014

SPECIfICATIONS

57
A300 CS OPERATING MANUAL
Doc. No. 12-7287-r03 (7/14/14)

Hide quick links:

Advertisement

Table of Contents
loading