GRASS VALLEY KARRERA K-FRAME Installation & Service Manua

GRASS VALLEY KARRERA K-FRAME Installation & Service Manua

Video production center
Hide thumbs Also See for KARRERA K-FRAME:
Table of Contents

Advertisement

KARRERA K-FRAME
VIDEO PRODUCTION CENTER
Installation & Service Manual
Software Version 8.0
071888005
NOVEMBER 2014

Advertisement

Table of Contents
loading

Summary of Contents for GRASS VALLEY KARRERA K-FRAME

  • Page 1 KARRERA K-FRAME VIDEO PRODUCTION CENTER Installation & Service Manual Software Version 8.0 071888005 NOVEMBER 2014...
  • Page 2 CERTIFICATE Certificate Number: 510040.001 The Quality System of: Grass Valley USA, LLC and its Grass Valley Affiliates Headquarters: 400 Providence Mine Road 15655 SW Greystone Ct. Nevada City, CA 95945 Beaverton, OR 97006 United States United States Kapittelweg 10 2300 So. Decker Lake Blvd.
  • Page 3 KARRERA K-FRAME VIDEO PRODUCTION CENTER Installation & Service Manual Software Version 8.0 071888005 NOVEMBER 2014...
  • Page 4: Copyright

    Germany, Austria, Eastern Europe: +49 6150 104 444 UK, Ireland, Israel: +44 118 923 0499 Copyright Copyright © 2014 Grass Valley. All rights reserved. This product may be covered by one or more U.S. and foreign patents. Belden, Belden Sending All The Right Signals, and the Belden logo are trademarks or registered trademarks of Belden Inc.
  • Page 5: Table Of Contents

    Karrera K-Frame System Examples ........
  • Page 6 Video Processor Door Removal Clearance ....... . KARRERA K-FRAME — Installation & Service Manual...
  • Page 7 Configuration Steps..........Karrera K-Frame Configuration Data........
  • Page 8 Setting IPs with the K-Frame Switcher Installer Program ....Karrera K-Frame System Names ........
  • Page 9 Karrera K-Frame Drive Access ........
  • Page 10 Grass Valley Web Site ........
  • Page 11 Introduction ............Grass Valley Switcher Device Monitoring by SNMP.....
  • Page 12 ..............KARRERA K-FRAME — Installation & Service Manual...
  • Page 13: Preface

    Other Documentation The Switcher Products Protocols Manual is available for developers and soft- ware engineers to use to design interfaces to the Karrera K-Frame system. The K-Frame Ethernet Tally is a proprietary protocol that provides all of the switcher status information required to calculate the Tally state of the...
  • Page 14 The K-Frame Ethernet Tally Software Development Kit (SDK) is available to approved vendors who need to interface with the Ethernet Tally system of the K-Frame. Contact Grass Valley Product Management for more information on this SDK. The KSP Graphical User Interface Instruction Manual provides information,...
  • Page 15: Safety Summary

    DANGER the marking. — A personal injury hazard exists but is not immediately acces- WARNING sible as you read the marking. — A hazard to property, product, and other equipment is present. CAUTION KARRERA K-FRAME — Installation & Service Manual...
  • Page 16: Symbols On The Product

    — Prior to servicing, remove jewelry such as rings, watches, Remove jewelry and other metallic objects. — Do not touch exposed connections, components or Avoid exposed circuitry circuitry when power is present. KARRERA K-FRAME — Installation & Service Manual...
  • Page 17: Cautions

    Use anti-static procedures, equipment and surfaces during servicing. — If you suspect product damage Do not operate with suspected equipment failure or equipment failure, have the equipment inspected by qualified service personnel. KARRERA K-FRAME — Installation & Service Manual...
  • Page 18 (ASICS). As a result, circuit board repair at the component level is very difficult in the field, if not impossible. For war- ranty compliance, do not troubleshoot systems beyond the board level. KARRERA K-FRAME — Installation & Service Manual...
  • Page 19: Sicherheit - Überblick

    — Wenn Sie diesen Begriff lesen, besteht ein unmittelbares Verletzu- GEFAHR ngsrisiko. — Wenn Sie diesen Begriff lesen, besteht ein mittelbares Verletzu- WARNUNG ngsrisiko. — Es besteht ein Risiko für Objekte in der Umgebung, den Mixer VORSICHT selbst oder andere Ausrüstungskomponenten. KARRERA K-FRAME — Installation & Service Manual...
  • Page 20 — Führen Sie interne Servicearbeiten nur aus, wenn eine weitere Person anwesend ist, die erste Hilfe leisten und Wiederbelebungsmaßnahmen einleiten kann. — Legen Sie vor Servicearbeiten Schmuck wie Ringe, Schmuck abnehmen Uhren und andere metallische Objekte ab. KARRERA K-FRAME — Installation & Service Manual...
  • Page 21 — Durch das unbefugte Öffnen wird die Garantie ungültig. Gerät nicht öffnen — Betreiben Sie das Gerät nicht an einer Richtige Spannungsquelle verwenden Spannungsquelle, die eine höhere Spannung liefert als in den Spezifika- tionen für dieses Produkt angegeben. KARRERA K-FRAME — Installation & Service Manual...
  • Page 22 Hersteller empfohlenen Typs aus. Entsorgen Sie gebrauchte Batterien entsprechend den Anweisungen des Batterieherstellers. Das Gerät enthält keine Teile, die vom Benutzer gewartet werden können. Wenden Sie sich bei Problemen bitte an den nächsten Händler. KARRERA K-FRAME — Installation & Service Manual...
  • Page 23: Consignes De Sécurité

    La signalétique suivante peut être apposée sur le produit: — risque de danger imminent pour l’utilisateur. DANGER — Risque de danger non imminent pour l’utilisateur. AVERTISSEMENT — Risque d’endommagement du produit, des installations MISE EN GARDE ou des autres équipements. KARRERA K-FRAME — Installation & Service Manual...
  • Page 24 — Ne réalisez pas une interven- Ne procédez pas seul à une intervention d’entretien tion d’entretien interne sur ce produit si une personne n’est pas présente pour fournir les premiers soins en cas d’accident. KARRERA K-FRAME — Installation & Service Manual...
  • Page 25 — Ne branchez pas ce produit à une Utilisez la source d’alimentation adéquate source d’alimentation qui utilise une tension supérieure à la tension nomi- nale spécifiée pour ce produit. KARRERA K-FRAME — Installation & Service Manual...
  • Page 26 Cette unité ne contient aucune partie qui peut faire l’objet d’un entretien par l’utilisateur. Si un problème survient, veuillez contacter votre distribu- teur local. KARRERA K-FRAME — Installation & Service Manual...
  • Page 27: Regulatory Notices

    Changes or modifications not expressly approved by Grass Valley Group can affect emission compliance and could void the user’s authority to operate this equipment.
  • Page 28: Canadian Certified Power Cords

    Amendment 1: 2009/12/17. CAN C22.2, No. 60950 C22.2 #60950-1 Issue 2007/03/01 Ed. 2 Information Technology Equipment-Safety-Part 1 General Requirements. EN60950 Safety of Information Technology Equipment, including Electrical Busi- ness Equipment. 2006/95/EC Low Voltage Directive KARRERA K-FRAME — Installation & Service Manual...
  • Page 29 EN 61000-4-5: Power Line Surge EN 61000-4-6: Conducted RF Immunity Radiated Magnetic Field Immunity US FCC Class A CISPR Pub. 22 (1985) Canada FCC Industry Canada ICES-003 Australia & New Zealand: AS/NZS 3548 KARRERA K-FRAME — Installation & Service Manual...
  • Page 30 Regulatory Notices KARRERA K-FRAME — Installation & Service Manual...
  • Page 31: Section 1 - Introduction

    Section Introduction Overview The Grass Valley K-Frame family of multi-format digital production switchers provides powerful, ground-breaking features designed to meet the widest range of requirements for live studio, mobile, and post-produc- tion applications. The K-Frame Video Processor is the heart of the system, providing exten- sive video switching and signal processing capabilities.
  • Page 32: Features

    M/E outputs. • Aux bus transitions for dissolves and wipes on aux bus outputs. • Interfaces with Grass Valley routers and Kaleido Multiviewers and their control systems. • Optional Integrated Image Store capable of delivering up to 32 GB storage of Stills (3,000 images) or “Movies”...
  • Page 33: K-Frame Standard Frame

    • The Controller M/E has a complement of 6 full keyers with Chroma Key and 2D-DPMs. • Up to 8 iDPMs (Integrated Digital Picture Manipulators), assigned as either floating iDPMs or within an eDPM at user’s discretion. KARRERA K-FRAME — Installation & Service Manual...
  • Page 34: K-Frame Compact S-Series Frame (Differences)

    MEs available, as well as the number of video inputs, outputs, GPIOs and Relay Tallies. Figure 1. K-Frame Video Processors K-Frame 13-RU Video Processor K-Frame 6-RU Video Processor Integrated Power Supplies Frame Power Supply 1-RU (For Standard K-Frame only) KARRERA K-FRAME — Installation & Service Manual...
  • Page 35: K-Frame Control Surfaces

    Karrera 3-ME 35 Control Panel Menu Panel Articulated Optional Touch Screen Karrera Menu Panel with Fanless PC Figure 3. Karrera 2-ME 25 Control Surface Karrera Menu on PC Karrera 2-ME 25 Control Panel (Customer Supplied PC) KARRERA K-FRAME — Installation & Service Manual...
  • Page 36: Touch Screen Menu Panel Option

    USB ports, two on the right side edge of the panel and two on the back for keyboard and mouse (wired or wireless are supported). A fanless PC, running Windows OS, is available which mounts behind the Menu Panel. KARRERA K-FRAME — Installation & Service Manual...
  • Page 37: Soft Panel (Ksp) Option

    The Menu application software provided with every K-Frame system can be run on a standard PC. This software accesses all the system’s function- ality, permitting mouse and keyboard control from a laptop, or remote control from any location on the network. KARRERA K-FRAME — Installation & Service Manual...
  • Page 38: Karrera K-Frame System Examples

    A K-Frame system can be subdivided into two suites, if desired, each of which can have two control surfaces. Hardware resources in the Video Pro- cessor Frame can be assigned to an individual suite during configuration, essentially creating two separate switchers sharing one K-Frame. KARRERA K-FRAME — Installation & Service Manual...
  • Page 39 Fanless PC and Articulated Arm KSP 1-ME Standard 13-RU Soft Panel Option K-Frame (Keyboard Included) (Customer Supplied PC) Suite 2 Karrera Menu on PC Karrera 2-ME 25 Control Panel (Customer Supplied PC) KARRERA K-FRAME — Installation & Service Manual...
  • Page 40: Supported Control Protocols

    (Trinix/Trinix NXT, Venus™, Triton™, and third-party routers; Jupiter and Encore router control systems) • Tally (contact closure) • K-Frame Ethernet Tally protocol • Ethernet CPL to control Grass Valley external remote AUX Panels • Grass Valley Editor protocol • SNMP system monitoring • Serial and Ethernet VDCP •...
  • Page 41: Section 2 - Control Surface Installation

    510.0 mm 3.3 in. 3.8 mm 20.1 in. 0.15 in. 55.1 mm 172.6 mm 2.2 in. 6.8 in. 482.6 mm 1413.5 mm 19.0 in. 55.6 in. 1440.6 mm 56.7 in. 510.0 mm 20.1 in. KARRERA K-FRAME — Installation & Service Manual...
  • Page 42 Figure 10. 3-ME Karrera Control Panel Rear Connections 12 Volt DC Out Ethernet USB* VGA* Aux Panel Control Cooling Fan Air Exhaust AC Power (not Ethernet) Air Intake * Reserved for maintenance use KARRERA K-FRAME — Installation & Service Manual...
  • Page 43: 2-Me Karrera Control Panel Installation

    12.4 in. 575.0 mm 313.7 mm 22.7 in. 13.9 in. 454.8 mm 665.1 mm 26.2 in. 17.9 in. 1221.7 mm 48.1 in. 335.3 mm 2ME Cutout Dimensions 13.2 in. 1223.7 mm 48.2 in. KARRERA K-FRAME — Installation & Service Manual...
  • Page 44: 2-Me Compact Karrera Control Panel Installation

    4 mm 20.1 in. 0.5 in. 0.5 in. 0.14 in. 55 mm 173 mm 2.2 in. 6.8 in. 483 mm 982 mm 19.0 in. 38.7 in. 1010 mm 39.8 in. 510.0 mm 20.1 in. KARRERA K-FRAME — Installation & Service Manual...
  • Page 45 Figure 16. 2-ME Compact Karrera Control Panel Rear Connections 12 Volt DC Out Ethernet USB* VGA* Aux Panel Control Cooling Fan Air Exhaust AC Power (not Ethernet) Air Intake * Reserved for maintenance use KARRERA K-FRAME — Installation & Service Manual...
  • Page 46: Karrera Menu On User Pc Installation

    Boot Camp partition or as a VM), and the Windows environment will need to be configured (including I/O device access, IP addresses, etc.). When a working Windows environment exists on the Mac, the Grass Valley Switcher Installer program can be used to install the Karrera Menu appli- cation into the Mac’s Windows environment, and the application can...
  • Page 47: Menu On User Pc Software Installation

    Menu on User PC Software Installation Karrera Menu Panel software is included on the Karrera Software USB stick, and is installed using the standard Grass Valley Switcher software installation process. The Karrera Menu application requires Microsoft .NET Framework software, which is also included on the USB stick.
  • Page 48: Menu Panel Dimensions

    129.4 mm 128.4 mm 3.84 in. 5.09 in. 5.06 in. 70.6 mm 2.78 in. 40.6 mm 1.60 in. 97.5 mm 3.84 in. 171.9 mm 170.9 mm 6.77 in. 6.73 in. 245.9 mm 9.68 in. KARRERA K-FRAME — Installation & Service Manual...
  • Page 49: Menu Panel Connectors

    Menu Panel chassis. Mounting the panel free-standing with the artic- ulated arm allows maximum air movement, and is the preferred installa- tion method. If an alternative method is used, ensure that all vents are unobstructed and adequate airflow is available. KARRERA K-FRAME — Installation & Service Manual...
  • Page 50: Fanless Pc Dimensions And Connectors

    USB 2.0 Headphone Power Hard Disk Reset Power Mic Input 1394 Port Port On/Off Figure 21. Fanless PC Rear Connectors DVI-D Audio Power Serial PS/2 Ports USB 2.0 Line Out Input Port Port Ethernet KARRERA K-FRAME — Installation & Service Manual...
  • Page 51: Menu Panel Articulated Arm Installation

    The supplied articulated arm is equipped with a flex-mount system, per- mitting a variety of mounting options (table-top, wall mount, etc.). See the documentation provided with the articulated arm for specific installation instructions. KARRERA K-FRAME — Installation & Service Manual...
  • Page 52: Menu Panel Hardware Installation With Articulated Arm

    For flat mounting directly to a vertical surface without using the articulated arm, two #10 screw sized washers (2.5 mm/0.10 in. thick) can be used at the lower two “U” bracket screw locations. KARRERA K-FRAME — Installation & Service Manual...
  • Page 53: Optional Local Aux Panel Installation

    445 mm 227 mm 158.6 mm 45 mm 17.5 in. 8.9 in. 3.1 in. 6.2 in. 122 mm 1.8 in. 4.8 in. 793 mm 31.2 in. 800 mm 31.5 in. 162 mm 6.4 in. KARRERA K-FRAME — Installation & Service Manual...
  • Page 54: Local Aux 25 Panel Dimensions

    2.1 in. 2.8 in. 32 mm 16 mm 1.3 in. 0.6 in. 25 mm Dimensions are mirrored. 1 in. Local Aux 25 are the same 25 mm as measured from corners. 1 in. KARRERA K-FRAME — Installation & Service Manual...
  • Page 55: Tabletop/Backsplash Cutout Installation

    809 +/-1 mm Ear Overlap 31.9 +/-.04 in. 17 mm 0.7 in. 159 +/-1 mm Local Aux Panel Cutout 6.3 +/-.04 in. Local Aux 25 Panel Cutout 619 +/-1 mm 24.4 +/-.04 in. KARRERA K-FRAME — Installation & Service Manual...
  • Page 56: Tabletop Bracket Installation: 2-Me And 3-Me Main Panels

    514 mm 20.2 in. 705 mm 335 mm 27.8 13.2 in. 1224 mm 485 mm 48.2 in. 19.1 in. 2-ME Main Panel Cutout Dimensions 1416 mm 55.7 in. 3-ME Main Panel Cutout Dimensions KARRERA K-FRAME — Installation & Service Manual...
  • Page 57: Tabletop Bracket Installation: 2-Me Compact Panel

    6.5 in. 2 mm and Main Panel upper edge. 0.1 in. (right of cutout) 521 mm 20.5 in. 485 mm 19.1 in. 984 mm 38.7 in. 2ME Compact Main Panel Cutout Dimensions Figure 30. KARRERA K-FRAME — Installation & Service Manual...
  • Page 58 Section 2 — Control Surface Installation KARRERA K-FRAME — Installation & Service Manual...
  • Page 59: Section 3 - Frames Installation

    K-Frame Video Processors require rear rack support. Cooling Requirements The maximum ambient temperature for a Karrera K-Frame chassis is 40- degrees C (104-degrees F) monitored at the air intake. Installing the frame in a closed or multi-unit rack assembly together with other units could increase the maximum ambient temperature for this unit.
  • Page 60: 13-Ru Standard Video Processor

    Mounting a K-Frame in a rack immediately below equipment that extends forward from the rack may not provide enough clearance to completely remove the K-Frame door. See 13-RU Standard Video Processor on page KARRERA K-FRAME — Installation & Service Manual...
  • Page 61 13-RU Standard Video Processor Figure 32. K-Frame 13-RU Dimensions (Top View) 442 mm 17.4 in. 566 mm 22.3 In. 602 mm 23.7 in. 37 mm 1.5 in. 483 mm 19.0 in. KARRERA K-FRAME — Installation & Service Manual...
  • Page 62 Figure 33. K-Frame 13-RU Rack Mounting and Cooling Airflow Rear Rack Support Air Exhaust (Chassis Top) Rear Rack Support Intake (Chassis Bottom) Intake (Chassis Bottom) CAUTION K-Frame installations require the use of the provided rear rack supports. KARRERA K-FRAME — Installation & Service Manual...
  • Page 63 Slots F18 - F11 Front Slots F6 - F1 (Reserved for future use. CAUTION The Video Processor front door must remain in place and closed during normal system operation to maintain maximum cooling efficiency. KARRERA K-FRAME — Installation & Service Manual...
  • Page 64 (DC power in, Up to 8 modules Reference, Ethernet and Module 1 Serial ports) Module 8 DIAGNOSTIC MODE OUTPUT OUTPUT OUTPUT OUTPUT INPUT INPUT INPUT INPUT Rear Slots R1 - R10 Slots R11 - R18 KARRERA K-FRAME — Installation & Service Manual...
  • Page 65: 6-Ru Compact Video Processor

    Mounting a K-Frame in a rack immediately below equipment that extends forward from the rack may not provide enough clearance to completely remove the K-Frame door. See 13-RU Standard Video Processor on page KARRERA K-FRAME — Installation & Service Manual...
  • Page 66 Section 3 — Frames Installation Figure 37. K-Frame 6-RU Dimensions (Top View 442 mm 17.4 in. 596 mm 22.0 In. 559 mm 23.5 in. 37 mm 1.5 in. 483 mm 19.0 in. KARRERA K-FRAME — Installation & Service Manual...
  • Page 67: 6Ru Compact S-Series Front Views With Doors Removed

    CAUTION K-Frame installations require the use of the provided rear rack supports. 6RU Compact S-series Front Views with Doors Removed The Compact S-series Frame includes four keyers per ME and two Multiv- iewers on the Controller board. KARRERA K-FRAME — Installation & Service Manual...
  • Page 68: 6Ru Compact Front Views With Doors Removed

    ME A Controller ME B Image Store Assembly Front Slots F1 - F4 CAUTION The Video Processor front door must remain in place and closed during normal system operation to maintain maximum cooling efficiency. KARRERA K-FRAME — Installation & Service Manual...
  • Page 69: 6Ru Rear View

    DIP Switch with LEDs (9) (two ports, usable Reset LEDs (15) and Text Display with door closed) RS-232 Button Keyboard NOTE: Ports and indicators here are intended only for diagnostic and service procedures. KARRERA K-FRAME — Installation & Service Manual...
  • Page 70: K-Frame Standard Power Supply Frame Installation

    AC Input IEC C19 (3) (to K-Frame) 38 mm 1.5 in. 36 mm 45 mm 1.4 in. 1.8 in. 97 mm 79 mm 3.8 in. 3.1 in. 217 mm 159 mm 8.5 in. 6.3 in. KARRERA K-FRAME — Installation & Service Manual...
  • Page 71: K-Frame Standard Power Supply Frame Rack Placement

    The K-Frame power supply frame is ideally rack mounted immediately above the Standard Video Processor chassis. The power supply frame is then supported by the lower chassis and eliminates the need for power supply rear rack supports. KARRERA K-FRAME — Installation & Service Manual...
  • Page 72 If mounting in an alternative location, allow for the 34” DC interconnect cable length. Figure 47. Isolated K-Frame Standard Power Supply Rack Installation Rear Rack Support Exhaust Rear Rack Support Intake KARRERA K-FRAME — Installation & Service Manual...
  • Page 73: K-Frame Standard Power Supply Cooling

    C13 style, to accommodate potentially higher currents. Cables provided with K-Frame systems are matched to the destination country’s standard. For example, in the USA C19 to NEMA 5-20P cables are pro- vided. Figure 48. USA Power Cable Example KARRERA K-FRAME — Installation & Service Manual...
  • Page 74: About Low Line (120V) Operational Considerations

    Most of the above is not an issue if high line (240V) operation is used. Since AC line currents are approximately half of those at low line, exceeding the current rating of a circuit should not be a problem. In areas where there is KARRERA K-FRAME — Installation & Service Manual...
  • Page 75: K-Frame Compact Power Supply Ac Requirements

    K-Frame with all options installed and running at 120 volts will draw a total of approximately 9 amps from the line cords. At 100 volts, this increases to approximately 10 amps. This load will be evenly distributed KARRERA K-FRAME — Installation & Service Manual...
  • Page 76: Replacing Compact Power Supplies

    Remove the power supply. 1. Open the front door of the Compact K-Frame. 2. Locate the lock and lock screw, located in the front, lower middle of the power supply labeled OPEN and LOCKED. KARRERA K-FRAME — Installation & Service Manual...
  • Page 77: Video Processor Door Removal Clearance

    If the K-Frame power supply is mounted directly above the K-Frame chassis, the chassis door can be completely removed after removing the power supply’s front screen. However, mounting a K-Frame in a rack immediately below other equipment that extends forward from KARRERA K-FRAME — Installation & Service Manual...
  • Page 78 If mounted below equipment that extends forward from the rack, allow at least 24 mm (0.94 in.) of vertical clearance above the K-Frame to permit door removal. A flush design 1 RU blank filler panel can be used for clear- ance, if required. KARRERA K-FRAME — Installation & Service Manual...
  • Page 79: Section 4 - System Cabling

    CAUTION The facility network used for your K-Frame system (and other video produc- tion equipment) should be kept separate from any external network, to prevent network traffic from adversely affecting K-Frame system operation. KARRERA K-FRAME — Installation & Service Manual...
  • Page 80: K-Frame Network Cabling

    Section 4 — System Cabling K-Frame Network Cabling Network connections are required between the Karrera K-Frame Video Processor, Control Panel, and optional Menu Panel PC. K-Frame Ethernet Switch The Ethernet switch built into the K-Frame auto-detects speed and polarity, and is 10/100/1000 Mbps capable. Either straight-through or crossover Ethernet cabling can be used.
  • Page 81: Control Panel Network Cabling

    (MEs, eDPMs, external devices, etc.) can be assigned to each suite, creating two switchers with one K-Frame. Each suite can be sub- divided into two control surfaces. Each control surface is intended for use KARRERA K-FRAME — Installation & Service Manual...
  • Page 82: Customer Supplied Ethernet Routers And Switches

    This reduces network traffic on the K-Frame network and keeps it isolated. Any Ethernet switches added specifically for use with the K-Frame system should be 1000 Mbps capable for the most efficient opera- tion (see Table KARRERA K-FRAME — Installation & Service Manual...
  • Page 83 Using a 1000 Mbps Ethernet switch enhances Image Store transfer speeds. Switch Recommended. Configuration not required, but does not provide Unmanaged remote monitoring capability. May be used. Requires configuration, but offers remote monitoring Managed capability. KARRERA K-FRAME — Installation & Service Manual...
  • Page 84: Factory Default Network Settings

    Five connections are required for the Touch Screen Menu option. If the articulated arm is used, some of these cables can be routed through chan- nels in the arm that have covers that click into place. KARRERA K-FRAME — Installation & Service Manual...
  • Page 85: Optional Local Aux Panel Cabling

    Com 3 to that front USB port. Optional Local Aux Panel Cabling The Karrera K-Frame Local Aux Panel is powered from the Karrera K- Frame Panel, using a 4-pin XLR cable. System control is provided using a RJ-45 connecting cable, which uses a proprietary communications protocol (not Ethernet).
  • Page 86: Video Cabling

    16 on each output module. Identical signals are present on each of the paired output connectors. All of the outputs carry the same video format, as determined by the standard selected and by the reference signals connected. KARRERA K-FRAME — Installation & Service Manual...
  • Page 87: Matchdef And Setdef Format Conversion

    Inputs must be within this range to be properly timed at the output. The calculation of the actual video delay of a specific input is the Nominal KARRERA K-FRAME — Installation & Service Manual...
  • Page 88 • Inputs that reach the switcher at the earliest point in the autotiming window (-B μs) will have a total delay equal to the Nominal Switcher Delay (A μs) plus the autotiming window range. This value is the Maximum Switcher Delay value (D μs). KARRERA K-FRAME — Installation & Service Manual...
  • Page 89: Timing Analyzer

    Figure 56. Video Settings Menu, This analyzer reports the timing position of a selected source relative to the Karrera K-Frame internal sync generator. The source is selected with the upper right soft knob and data pad. The relative position of Analyzer Source that source is reported in lines and μs.
  • Page 90: Time Zones And The Autotiming Window

    Center of Time Zone 1 Center of Time Zone 5 Window Autotiming Range Autotiming Range Too Early for Time Zones 5 and 6 Too Late for Time Zone 1 Center of Autotiming Window KARRERA K-FRAME — Installation & Service Manual...
  • Page 91: Clipstore Cabling

    ClipStore (K2 Summit/Solo, Figure 50 on page 79). Connect an Ethernet cable from the Karrera K-Frame, either directly or through a ded- icated Ethernet switch, to the bottom left (of the four) 100BT/1000BT Ethernet ports on the Summit/Solo backplane.
  • Page 92 (Play Only) The ClipStore server (4-channel Summit/2-Channel Solo) can be connected directly to the frame. It is also possible to connect to the ClipStore directly from a router and not use any switcher outputs. KARRERA K-FRAME — Installation & Service Manual...
  • Page 93 Also, DAs (Distribution Amplifiers) can be used to distribute Karrera K- Frame Aux Bus output. The example in Figure 60 shows DAs being used for both the Video and Key Aux Bus outputs from the frame. KARRERA K-FRAME — Installation & Service Manual...
  • Page 94: Video Processor Frame Gpi/Tally Interface

    The nominal contact rating specification for each relay is 1A, 60 V. Note A tally interface that communicates with third party devices over Ethernet is also available. Refer to the separate Switcher Products Protocols Manual for specific information. KARRERA K-FRAME — Installation & Service Manual...
  • Page 95: Gpi And Tally Connections

    GPI In pin and one of the two GPI In Com pins (1 and 34). Pins 1 and 34 of each connector is connected to ground. For applications that span across more than one connector, only one ground (common) connection is required. KARRERA K-FRAME — Installation & Service Manual...
  • Page 96: Tally/Gpi Outputs

    This common or isolated bus scheme can extend across multiple connectors. For example, a situation may require two iso- lated common buses, half of the commons form the first common bus and the other half form the second common bus. KARRERA K-FRAME — Installation & Service Manual...
  • Page 97 The solid state relays are bidirectional; either polarity voltage can be applied. If the switcher GPI/Tally outputs are used to drive downstream DC relays, be sure to install diodes across the KARRERA K-FRAME — Installation & Service Manual...
  • Page 98: Pin Assignments

    Pin 9 Pin 6 TxA (-) RxA (-) Chassis Ground Chassis Ground RS-232 Ports RS-232 serial ports are located on each processor board (Video Processor, Panel Processor, Menu PC), available for maintenance and diagnostics. KARRERA K-FRAME — Installation & Service Manual...
  • Page 99: Gpi In, Tally, Gpi Out

    GPI In 9-16 Tally 25-48 GPI Out 9-16 GPI In 17-24 Tally 49-72 GPI Out 17-24 GPI In 25-32 Tally 73-96 GPI Out 25 - 32 GPI In 33-40 Tally 97-120 GPI Out 33-40 KARRERA K-FRAME — Installation & Service Manual...
  • Page 100 GPIOut19Y GPIOut27AG GPIOut35AJ GPIOut4G GPIOut12Q GPIOut20Y GPIOut28AG GPIOut36AJ GPIOutComH GPIOutComR GPIOutComZ GPIOutComAH GPIOutComAK GPIOut5H GPIOut13R GPIOut21Z GPIOut29AH GPIOut37AK GPIOut6H GPIOut14R GPIOut22Z GPIOut30AH GPIOut38AK GPIOut7H GPIOut15R GPIOut23Z GPIOut31AH GPIOut39AK GPIOut8H GPIOut16R GPIOut24Z GPIOut32AH GPIOut40AK KARRERA K-FRAME — Installation & Service Manual...
  • Page 101: Section 5 - Basic Configuration

    Section Basic Configuration Introduction This section provides basic system configuration information for the Karrera K-Frame Video Production Center. Refer to the Kayenne/Karrera K- Frame Release Notes for information specific to your current software ver- sion. Configuration Steps Karrera K-Frame basic system configuration includes the following steps: 1.
  • Page 102: Karrera K-Frame Configuration Data

    Karrera K-Frame system operation. When the Video Processor resets, these settings are read and enacted. Configuration settings can be saved to files and loaded back into the Karrera K-Frame system at a later time to restore those operational settings.
  • Page 103: Gv Switcher Menu Application

    The GV Switcher menu application is used to configure your Karrera K- Frame system. This application can run on a user supplied PC, using a mouse and keyboard, and can run on the optional Karrera K-Frame Touch Screen menu, allowing system operation by touching the screen.
  • Page 104: Menu Top Line

    • The center portion of the top line displays operations status messages. • The right portion of the top line is an operator notification area, where messages generated by the Karrera K-Frame system are displayed. Data Pads and Touch Buttons...
  • Page 105: Data Pads And Soft Knobs

    Note The optional eDPM system has its own set of operating menus, accessed by touching the eDPM button on the lower left. For basic Karrera K-Frame con- figuration be sure the SWR button is selected. System Power Up and Initialization The Karrera K-Frame Video Processor Frame, Control Panel, and menu application must be running for full system operation.
  • Page 106: Power And Initialization Indications

    Figure 65. Eng Setup Status Menu Default Karrera K-Frame System Communications Karrera K-Frame systems ship with factory default settings that allow com- ponents to communicate with one another when powered up, provided KARRERA K-FRAME — Installation & Service Manual...
  • Page 107: Establishing Menu To Frame Communication

    PC: • The Video Processor Frame must be powered up and running. • The IP address of the Karrera K-Frame Menu Panel must be set to be on the same network as the Video Processor Frame. • Ethenet cabling should connect the Control Panel to the Video Pro- cessor Frame, either directly or though an Ethernet switch.
  • Page 108 Menu Panel application, or Restart Now you can , make changes to the Image Store IP Address and Track Cancel DPOPs from Panel IP, and then do a single Menu Panel restart. KARRERA K-FRAME — Installation & Service Manual...
  • Page 109: Network Configuration

    Menu Panel should be fully operational. Network Configuration IP Address Background Information Each device connected to any Ethernet network must have a unique IP address. An IP address has two components: the network address and the KARRERA K-FRAME — Installation & Service Manual...
  • Page 110: Gateway Ip Addresses

    Karrera K-Frame system components, or have multiple Karrera K-Frame systems on the same network cabling. For example, if more than one Karrera K-Frame system resides on the same network, the IP address of each additional Karrera K-Frame device must be changed before it is con- nected to the network.
  • Page 111: Setting Ips With The K-Frame Switcher Installer Program

    A mouse and keyboard is required to navigate through the K-Frame Installer program and enter IP numbers and system names. Standard USB devices can be connected to any of four available ports on the Karrera K-Frame Menu Panel. Karrera K-Frame System Names The K-Frame Installer program includes a hierarchy display of Karrera K- Frame system components.
  • Page 112: Set Ip Procedure Using K-Frame Installer Program

    Frames and Control Panels will be grouped under that name. If you have more than one Karrera K-Frame system, be sure to change the name of the Video Processor Frames so you can identify them easily. When each Frame has a unique name, the Control Panels configured with each Frame will be grouped with that system name.
  • Page 113 See Reset Procedures on page 230 for details. CAUTION Changing the IP address of an operating Karrera K-Frame component can disrupt system communications until matching changes to the addresses other components use are made on those other devices. Registering new IP Node addresses may also be necessary.
  • Page 114: Other K-Frame Switcher Installer Program Functions

    IP addresses. Set IP Procedure Using Device Web Pages You need to know the current IP address of the Karrera K-Frame Video Pro- cessor or Control Panel before you can change it using a Web browser, mouse and keyboard.
  • Page 115 The device will boot up with the new IP address. When a Video Processor Frame IP address has been changed, communica- tions will no longer occur with any Karrera K-Frame system devices that are configured to use the old frame IP address. You will need to go to each...
  • Page 116: Changing Image Store Ip Address

    • K-Frame Switcher Installer program (see Setting IPs with the K-Frame Switcher Installer Program on page 111). • the Karrera K-Frame Control Panel webpage (see Set IP Procedure Using Device Web Pages on page 114), • the Grass Valley NetConfig application, or •...
  • Page 117 4. Use the keypad buttons to enter the new IP address values. When the new IP address has been entered, select (press Enter Figure 76. Karrera K-Frame Panel IP Address Mode, Entering New IP Values Menu Panel IP Address ###.###.###.###...
  • Page 118 Section 5 — Basic Configuration CAUTION Changing the IP address of an operating Karrera K-Frame component can disrupt system communications until matching changes to the addresses other components use are made on those other devices. Re-registering IP Node addresses may also be necessary. See Control Panel Registration page 122 for more information.
  • Page 119: Changing Menu Panel Ip Address

    Remote Aux Panel. If more than one Remote Aux Panel will be used on your Karrera K-Frame system, you will need to change each panels’ IP addresses so none are duplicated, and this must be done before you connect them to the network.
  • Page 120 Section 5 — Basic Configuration Figure 80. Panel Description Screen 3. Click on Network . A Network Configuration screen will appear, displaying the factory default settings. KARRERA K-FRAME — Installation & Service Manual...
  • Page 121 6. Disconnect the PC, and connect the Remote Aux Panel to the Karrera K- Frame system network. 7. Repeat this procedure on all the Remote Aux Panels to be used with your Karrera K-Frame system, entering a unique IP address for each Remote Aux Panel. See Remote Aux Panel Registration...
  • Page 122: Restoring The Default Ip Address

    5. Press the flashing button. This resets the IP address to factory default. Registering Karrera K-Frame System Nodes When IP addresses have been changed on Karrera K-Frame system compo- nents, or new components are added, the Video Processor Frame needs to know what new addresses it will use to communicate with those compo- nents.
  • Page 123: Remote Aux Panel Registration

    Stripe, with Remote Aux Panels, which are small panels used to change Aux Bus sources from a different location. The Local Aux Panel Stripe is not con- figured with the following menus. 1. Touch Eng Setup Node Settings Remote Aux IP Network KARRERA K-FRAME — Installation & Service Manual...
  • Page 124: Control Panel Brightness Adjustment

    Individual panel area illumination levels cannot be adjusted in the field. However, the relative brightness of button tally, source name dis- plays, and text displays can be adjusted on a global basis to meet individual KARRERA K-FRAME — Installation & Service Manual...
  • Page 125: Lever Arm And Joystick Calibration

    Lever Arm and Joystick Calibration requirements (for example, to accommodate varying ambient room lighting levels). 1. Access the Karrera K-Frame Panel webpage, by entering its IP address in a web browser, then clicking on Configuration Figure 84. Control Panel Brightness Adjustment 2.
  • Page 126: Engineering Setups

    234. Engineering Setups Karrera K-Frame inputs and outputs are connected to the rear of the Video Processor Frame. These video signals need to be configured to your facility’s requirements. Engineering Setups defines Karrera K-Frame system component functionality and how it is cabled into a facility. Engi- neering setups are intended to be used and maintained by technical staff, and can be loaded and saved to disk.
  • Page 127: Source Definition Inputs

    Table 12. Standard K-Frame Source Definition Outputs Outputs Modular Outputs 1-16 17-32 33-48 49-64 65-68 73-76 81-84 89-92 69-72 77-80 85-88 93-96 Table 13. Compact K-Frame Source Definition Outputs Outputs Modular Outputs 1-16 17-32 65-68 73-76 69-72 77-80 KARRERA K-FRAME — Installation & Service Manual...
  • Page 128: Source Definition Menu

    Note The number of usable input connectors depends on the number of ME boards installed in the Karrera K-Frame Video Processing (24 inputs per board). KARRERA K-FRAME — Installation & Service Manual...
  • Page 129: External Device Source Definition

    Engineering names are entered in the Eng Setup Source Definition menu, as described above. Engineering source IDs are numeric only, and are avail- able on data pads and scroll knobs for quick selection. The Karrera K-Frame system also has logical IDs, that can be used for source patching, as explained later.
  • Page 130: Name Display Hierarchy

    ). The same set of engi- Eng Setup Eng Login neering names will be used by both Karrera K-Frame suites, however. Name Display Hierarchy If a source’s engineering name is left blank, the Eng ID number will be used. If no alternative names are defined for that source, then that Eng ID number will appear on all the Karrera K-Frame system displays.
  • Page 131 When multiple names are created, try to keep the first four characters unique, and make different names for the same source similar for ease of recognition. KARRERA K-FRAME — Installation & Service Manual...
  • Page 132: Fixed Sources

    • Eng Setup, Outputs menu Source Patch Feature The Karrera K-Frame system provides a way to map engineering source IDs to logical IDs, using the Source Patch feature. By default this mapping is one-to-one, but this feature can be used to quickly set up production ele- ments for use in a different facility.
  • Page 133: Button Mapping

    Tally and associations with external devices are based on engineering sources. Button Mapping After sources have been defined they can be mapped to Karrera K-Frame system Control Panel buttons. The Button Mapping menu (accessed by touching ) is used to map the sources...
  • Page 134: Changing Output Assignments

    Section 5 — Basic Configuration Changing Output Assignments The Outputs menu is used to change the Karrera K-Frame system output assignments. The current output assignments can be viewed in this menu. Press to access this menu. Eng Setup Outputs Figure 87. Outputs Menu The scrolling list of data pads along the left side of the screen shows the cur- rently assigned output for each listed module output connector.
  • Page 135: Aux Bus Configuration

    Aux Bus control, or using Remote Aux Panels delegated to control that Aux bus. The number of Aux buses on a Karrera K-Frame system varies, depending on how the physical outputs have been mapped. Any output that is not configured as Fixed or Switched Preview is available for use as an Aux bus.
  • Page 136 Section 5 — Basic Configuration Video Only Aux Bus When the button is not selected, the Aux bus is configured as a Aux Bus Pair single video-only output. Figure 88. Output Assignments Menu, Video Only Aux Bus KARRERA K-FRAME — Installation & Service Manual...
  • Page 137: Me Viewer

    (ME) pM source can be assigned one of six multiple signal arrangements, in User Setups/Suite Prefs. Assigning this source to a physical output connector permits viewing that arrangement of signals on a monitor. KARRERA K-FRAME — Installation & Service Manual...
  • Page 138: Switcher Tally Configuration

    The Switcher Tally menus also allow the user to map Engi- neering Sources to the tally relays. Up to 96 tally relay outputs are available on a Karrera K-Frame Video Processor, 24 for each installed Controller or ME board. Tally is recalculated and refreshed every field.
  • Page 139: About Tally Systems

    Engineering Setups Note Tally Contribution is an alternative electronic tally mechanism that can be assigned to a Karrera K-Frame Video Processor serial port. Refer to the sep- arate Grass Valley Switcher Protocols Manual for technical information. About Tally Systems In general, a tally system identifies which sources to the switcher contribute to the final picture at a selected point in the video chain.
  • Page 140: Switcher Tally Calculator Menus

    The Switcher Tally menus are used to select calculators, methods, and levels, name calculators, and assign items to Tributaries. Karrera K-Frame has six independently running tally calculators. For example, the system can calculate On Air tally independently for suite 1 and suite 2, and at the same time can calculate Look Ahead tally, and ME output tallies for three MEs.
  • Page 141 Groups Enabled calculator, by group letter (A, B, C, D, corresponding to Tally/GPI connec- tors 1-4 on the rear of the Karrera K-Frame Video Processor). To Enable a Tally Relay Group, it must first be turned on, using the button for Calc On that calculator.
  • Page 142 2. Touch the button to open a keypad you can use to name Calc 1-4 Name that calculator. 3. Choose the button for the Karrera K-Frame suite that will use Suite 1-2 this calculator. 4. Touch a button on the right.
  • Page 143 Use the Look Ahead Preview procedure above, but choose PGM/PST, ME, or Aux, on the left, and then select the desired bus in the center of the screen. Repeat for all the buses you wish to tally. KARRERA K-FRAME — Installation & Service Manual...
  • Page 144: Relay Assign Menu

    The Relay Assign menu is used to assign the Tally Calculators to Relay Groups, and assign Engineering Sources to relays on the Video Processor Frame GPI/Tally connectors. Touch the Relay Assign tab to access the menu. KARRERA K-FRAME — Installation & Service Manual...
  • Page 145 Tally Relay Group Group. The A, B, C, and D Tally Groups correspond to Tally/GPI connec- tors 1 through 4 on the rear of the Karrera K-Frame Video Processor. - Assigns the Tally Calculators to the delegated Tally Calculation Enables Group.
  • Page 146: About Mv Green Tally Calculations For Multiviewer On-Air And Green

    PST bus, in a typical configuration, communicating that those sources are in LAP and can transition to on-air next. 1. Select Eng Setup Switcher Tally 2. Select the button in the Tally System pane (upper right). MV Tally KARRERA K-FRAME — Installation & Service Manual...
  • Page 147: Set Source Names With External Ethernet Tally

    Frame that will modify any or all source names in the system, including the Engineering Names for each source. Additionally, the Control Panel, OLED, and Menu names for each logical source in each suite can be set externally. KARRERA K-FRAME — Installation & Service Manual...
  • Page 148 • Red—external Ethernet tally connection error 3. Select the Connection Status button to connect to the external Enable Ethernet tally client. 4. Enable the Source Name Control by selecting the button for the Enable external Ethernet tally connection. KARRERA K-FRAME — Installation & Service Manual...
  • Page 149: Clipstore Configuration

    The NetConfig Network Configuration Tool is installed as part of the Karrera K-Frame software. Note Make note of the ClipStore IP Address, it will be used later to enable Clip- Stores as external devices later in the Karrera K-Frame configuration process. KARRERA K-FRAME — Installation & Service Manual...
  • Page 150: Karrera K-Frame System Preparation

    Karrera K-Frame Configuration Configuring ClipStore as a Node ClipStore must be configured as a node in the Eng Setup, Node Settings menu before the Karrera K-Frame system can communicate with the Summit/Solo ClipStore server. 1. Verify there is a valid network connection.
  • Page 151 ClipStore to the K-Frame are Inputs 25-32. ClipStore can record Video only, Key only, or Video/Key clips. To do this, both a video and a key for the video must be configured for each ClipStore channel. KARRERA K-FRAME — Installation & Service Manual...
  • Page 152 Key source you will use for the ClipStore channel. 6. Configure the Source Type: a. Touch the mode button in the Source Type pane. Device b. Touch the data pad, the External Device List is External Device displayed. KARRERA K-FRAME — Installation & Service Manual...
  • Page 153 Source Type pane to select it. Direct 5. Give the ClipStore key input an Engineering Name if desired (CS-1K, Figure 101), by touching the data pad and entering the Engineering Name name in the pop-up keyboard. KARRERA K-FRAME — Installation & Service Manual...
  • Page 154 Set the switcher outputs that are feeding into ClipStore. By selecting an Aux bus then touching one of the CS-1 through CS-4 enable buttons, those Aux bus outputs will be paired. In other words, if you select the output, then KARRERA K-FRAME — Installation & Service Manual...
  • Page 155 Local Aux area and/or can be button mapped as desired. When acquiring CS channels in another suite, before reassigning CS chan- nels: 1. In the Outputs menu, deselect the CS channels to be acquired (Figure 102). KARRERA K-FRAME — Installation & Service Manual...
  • Page 156: Clipstore Config Menu

    103). A dialog is displayed when this button is pressed (Figure 104), stating that all clips will be ejected as part of this oper- ation; keep this in mind if considering this operation during a broadcast. KARRERA K-FRAME — Installation & Service Manual...
  • Page 157: Assigning Clipstore Channel Resources To A Suite

    Eng Setup, Acquire Resources, Effects, Stores & Viewers menu (Figure 105). For information about acquiring suite resources, see the Divide Resources Between Suites on page 185. Figure 105. ClipStore Acquire Resources KARRERA K-FRAME — Installation & Service Manual...
  • Page 158: Setting The Summit/Solo Ip Address

    1. Disable the FBWF (File Based Write Filter) a. Click on the menu and navigate to Start All Programs Grass Valley b. Click on (top of list). Write Filter Utility The FBWF Manager is displayed. KARRERA K-FRAME — Installation & Service Manual...
  • Page 159 Engineering Setups Figure 106. FBWF Manager KARRERA K-FRAME — Installation & Service Manual...
  • Page 160 Figure 107. Disable/Enable Filter Settings d. Click e. At the reboot prompt, click Figure 108. Reboot Prompt 2. Once the server has rebooted, enter your login and password. 3. Right-click on Network Places 4. Click Properties KARRERA K-FRAME — Installation & Service Manual...
  • Page 161 Figure 109. Network Connections—Control Team 6. Click Properties 7. Scroll down to “Internet Protocol (TCP/IP)” and click to highlight it. Figure 110. Control Team Properties—TCP/IP Disable/Enable Filter Settings 8. Click Properties The TCP/IP Properties Dialog is displayed. KARRERA K-FRAME — Installation & Service Manual...
  • Page 162: Camera Control With Ethernet Tally Configuration

    Step 2. Reboot the ClipStore Summit/Solo server. Camera Control with Ethernet Tally Configuration The Karrera K-Frame system uses Ethernet to communicate with the LDK Connect Gateway. Some basic configuration is required in the Eng Setup menu. KARRERA K-FRAME — Installation & Service Manual...
  • Page 163: Node Settings

    Video Processor Frame Node Settings In the Eng Setup, Node Settings menu, enter a valid IP Address for the camera gateway and touch the Enable button. When connected, the LDK Connect LED will turn green. KARRERA K-FRAME — Installation & Service Manual...
  • Page 164: Source Definitions

    Section 5 — Basic Configuration Figure 113. Camera IP/Enable, Node Settings Menu Source Definitions To enable camera control from the Karrera K-Frame, the source is defined as a “Camera” type then assigned as a camera in the Eng Setup, Source Definition menu.
  • Page 165 Figure 114. Camera Source Type, Source Definition Menu 1. Touch the desired source in the Source List (Figure 114). 2. Set the Video Input and Key Mode (see the Karrera K-Frame User Manual for more information). 3. Touch the source type button in the Source Type pane...
  • Page 166: Acquire Resources

    Camera resources are acquired in the Eng Setup, Acquire Resources, Camera Control menu. Camera resource acquisition is represented in the Camera Controls Acquired in Suite pane in the Camera Controls menu as follows: Green—Successfully acquired in the current suite KARRERA K-FRAME — Installation & Service Manual...
  • Page 167 4. Touch the data pad of the desired suite. 5. Return to the Eng Setup, Acquire, Camera Control menu and touch the component buttons you wish to acquire to the suite. 6. Touch the button. Acquire Selected KARRERA K-FRAME — Installation & Service Manual...
  • Page 168: Switcher Ethernet Camera Tally

    Section 5 — Basic Configuration Switcher Ethernet Camera Tally The Karrera K-Frame system provides a quickly connected, reliable, three color tally (Red, Yellow, and Green) via Ethernet to Grass Valley cameras. Figure 117. Switcher Tally LDK Camera Ethernet Menu—Six-Keyer System Tally Calc Menus As with Switcher Tally, the LDK Camera Ethernet menu is used to select calculators, name calculators, and assign bus contributors to tributaries.
  • Page 169 Engineering Setups Figure 118. Color Assign Menu KARRERA K-FRAME — Installation & Service Manual...
  • Page 170: User Setups

    User Setups are intended primarily for operators, to allow them to cus- tomize their working environment. However, some settings affect basic system operation. The engineer in charge of a Karrera K-Frame system should create and save at least one default set of User Setups (Panel Prefs and Suite Prefs) so the system can be set to a known state.
  • Page 171 Source Filter numeric source name filter. Only source names that begin with the entered text will be displayed in the scrolling to the immediate left. • The button clears the source filter. Show All KARRERA K-FRAME — Installation & Service Manual...
  • Page 172: Suite Prefs

    The Default Keyframe menu is accessed by touching User Setups Suite Prefs Default Keyframe Figure 121. Default Keyframe Menu To Learn a Default Keyframe: 1. Setup the entire Control Panel to the desired state. KARRERA K-FRAME — Installation & Service Manual...
  • Page 173: Configuration File Save And Load

    Configuration File Save and Load Karrera K-Frame File Browser The Karrera K-Frame system has a file browser. You can browse through folders on the local Karrera K-Frame Menu hard disk, the Karrera K-Frame Video Processor, and the entire network file hierarchy of mapped drives.
  • Page 174: File Storage Organization

    Karrera K-Frame Drive Access The Karrera K-Frame File Operation menus can access directories located on the USB Memory Stick in the Video Processor Frame (System Storage) and the Menu Panel hard drive (Remote Storage). Local and network drives mapped on the Menu Panel’s Windows system are also accessible...
  • Page 175: File Type Extensions

    File Type Extensions Karrera K-Frame files are named by the user when saved, and this name appears below the icon in the browser. The extension for each system file type is listed in Table Table 15.
  • Page 176: Eng Setup File Operations

    Section 5 — Basic Configuration Non-Karrera K-Frame generated file icons show the file name with exten- sion, and displays the extension letters in the icon. Eng Setup File Operations The Eng Setup, Save Load menu is used to save and load engineering setups information.
  • Page 177: Utilities Pane

    3. Touch the button. Load CAUTION The Load button immediately replaces information the Karrera K-Frame system is currently using with the selected file information. When configura- tion files are loaded, significant changes to system operation are possible. KARRERA K-FRAME — Installation & Service Manual...
  • Page 178: Multiple Suite Resource Sharing

    Section 5 — Basic Configuration Multiple Suite Resource Sharing Introduction The Resource Sharing feature permits the allocation of Karrera K-Frame system resources between two suites. This allows independent system operation from multiple locations without conflict. Logical resource assignments allow the reuse of E-MEM effects in either suite regardless of which specific hardware resources were allocated.
  • Page 179: Independent Resource Sharing

    An example of independent sharing is splitting a 4-ME Karrera K-Frame system into two independent 2-ME switchers. Figure 125. Independent Resource Sharing Example...
  • Page 180: Control Surface

    A control surface is generally a group of panels which interact and provide a single user a unified work surface. An example of this type of control surface is a Control Panel and Menu Panel of a 4-ME Karrera K-Frame system. These panels combine to form a Technical Director’s (TD) control...
  • Page 181: Logical Aux Buses

    Aux buses assigned to that suite. External Control Points Some types of Karrera K-Frame system control originate from an external location, like an edit controller, or a GPI contact closure. The Resource Sharing feature accommodates these control points differently.
  • Page 182: Setting Up Resource Sharing

    Setting Up Resource Sharing Preparation Your Karrera K-Frame system should first be fully operational. For new customers, an initial system configuration will be required. This basic setup will become the baseline for suite 1 operation. This includes having an Eng...
  • Page 183: Configure Control Surfaces

    Ports & Devices GPI Outputs • Editor Ports, if used, are permanently assigned for use by each suite Eng Setup Ports & Devices, Editor Ports • Switcher Tally ( Eng Setup Switcher Tally KARRERA K-FRAME — Installation & Service Manual...
  • Page 184 Each suite has its own, logical set of outputs that are identically numbered. Use the Suite 1 and Suite 2 buttons to assign them to a suite. Figure 128. PGM Output Assigned to Suite 2 KARRERA K-FRAME — Installation & Service Manual...
  • Page 185: Divide Resources Between Suites

    Multiple Suite Resource Sharing Divide Resources Between Suites Note Changes to Suites and Resource Sharing can have serious Karrera K-Frame system operation impacts that may not be completely obvious. For this reason, precautionary messages requiring a response are posted. 1. If necessary, go to...
  • Page 186 3. To acquire installed DPM options, move available iDPM Channels from Available to Channels using the arrow keys. Any number of licensed iDPM channels can be acquired to the selected resource, or acquired as eDPMs using the Acquire Resources menu. KARRERA K-FRAME — Installation & Service Manual...
  • Page 187: Save Default Multi-Suite Engineering Setups File

    Similar to Suite Prefs above, Panel Prefs files can be created and saved for each control surface, if you wish. For engineering troubleshooting pur- poses, you may be able to define and save a single Panel Prefs file for use on any control surface. KARRERA K-FRAME — Installation & Service Manual...
  • Page 188: Delegate Stripes To Mes In Each Suite

    Operators should also test any EMEMs, RMEMs, or other items created or saved previously to be sure they work properly with their currently acquired resources. KARRERA K-FRAME — Installation & Service Manual...
  • Page 189: Engineering Login

    Engineering Login Engineering Login A Karrera K-Frame system can be configured as two suites, with each suite having up to two control surfaces. The Eng Login menu is used to choose which suite and control surface the GV Switcher menu will interact with and control.
  • Page 190: Setdef And Matchdef

    SetDef and MatchDef The SetDef and MatchDef options permit line rate signal format conversion of selected Karrera K-Frame system outputs and inputs. SetDef output and MatchDef input conversion is licensed in groups of four. Connectors are active when the associated Modular I/O board is present and the license is enabled.
  • Page 191: Matchdef Input Conversion

    MatchDef Input Conversion When MatchDef Mode is selected, the Modular I/O buttons report the current Mode, Engineering Name of the input, Suite 1 or 2 (S1 or S2), KARRERA K-FRAME — Installation & Service Manual...
  • Page 192 Cut are displayed, depending on the format selected. These controls are identical to those used for SetDef. The button behaves the same Sync/Scale as the SetDef button, but also employs frame sync circuitry. Scale KARRERA K-FRAME — Installation & Service Manual...
  • Page 193: Video Settings

    Digital reference. This should only be used temporarily, for troubleshooting or initial system test, because an interruption of that input signal can cause Karrera K-Frame system problems. KARRERA K-FRAME — Installation & Service Manual...
  • Page 194: Frame Operating Mode

    Live Mode and Film Mode processing is exactly alike. When the K-Frame is set to a psf Frame Operating Mode, it uses “Live Mode” processing for smother internally generated motion, while retaining some “Film Look” aesthetics. KARRERA K-FRAME — Installation & Service Manual...
  • Page 195: Other Settings

    Command Processing These controls determine when commands (like source selections or the initiation of mixes or wipes) will be enacted by the Karrera K-Frame system (also known as field dominance). These controls can be useful for consis- tent match frame editing.
  • Page 196: Default Idpm Crop

    SMPTE RP-187 establishes recommended practices for standard image sizes (production aperture, clean aperture). If a facility conforms to these practices, the Karrera K-Frame system default values will be correct and no adjustment should be necessary. Changing the default crops is not recom- mended, unless absolutely necessary.
  • Page 197: Frame Suite Nodes & Id Menu

    Note Do not change device or suite names unnecessarily, as this could cause con- fusion to other Karrera K-Frame system users. Mapping Logical Remote Aux Panels The Remote Aux Logical Map menu is used to assign Aux Buses for control by that Remote Aux Panel.
  • Page 198 1. Highlight a Panel Delegation button at the top of the screen. 2. Touch one of the Logical Aux Buses buttons on the lower screen. That Aux Bus will then be selected when that Remote Aux Delegation button is pressed on that panel. KARRERA K-FRAME — Installation & Service Manual...
  • Page 199: Remote Aux Button Mapping

    • The data pad and scroll knob on the upper right can be Source Number used to quickly select a Karrera K-Frame source by its logical ID number • The button at the bottom prevents the source list from scrolling Lock when choosing different Remote Aux buttons.
  • Page 200: About The Status Menu

    E-MEM, Macro, and also any frame software diagnostics data files that may exist (see Diagnostic Data Collec- tion below). If you need to contact Grass Valley for assistance about any software problems, the engineering team will want these files for efficient troubleshooting.
  • Page 201: Acquire Resources

    For the Stan- dard K-Frame, an additional dedicated Multiviewer resource (that does not use an available ME resource) named MX-MV is provided for use in either Suite 1 or Suite 2. KARRERA K-FRAME — Installation & Service Manual...
  • Page 202 Acquire Resources menu; zero is displayed when all licensed Multiviewers are allocated. If adding multiviewer resources in another suite: 4. Select the menu category button. Eng Login 5. Select Change Identity 6. Select another suite identity. 7. Select when prompted to continue. KARRERA K-FRAME — Installation & Service Manual...
  • Page 203: Acquire Multiviewer Resources With A Compact Frame

    Standard Frame only so it will be shown as NP (Not Present) in the Eng Setup, Acquire Resources menu for the Compact K-Frame. It cannot be acquired but shows created with the Compact K-Frame can be used on the Standard K-Frame where the MX-MV resource can be acquired. KARRERA K-FRAME — Installation & Service Manual...
  • Page 204 Result: The currently selected Multiviewer layout is available to an external monitor. If adding a second multiviewer display: 7. Select the menu category button. Eng Login 8. Select Change Identity 9. Select another suite identity. KARRERA K-FRAME — Installation & Service Manual...
  • Page 205: Acquire Multiviewer Resources With A Compact S-Series (Four-Keyer) Frame

    5. With the button selected (top right of menu) using the Fixed Sources scroll bar or filter for the scrolling sources list, find and select one of the fixed multiviewer sources, for example Mview 1 KARRERA K-FRAME — Installation & Service Manual...
  • Page 206 Eng Login 7. Select Change Identity 8. Select another suite identity. 9. Select when prompted to continue. 10. Allocate a second Multiviewer physical resource in the Eng Setup, Acquire Resources menu as previously described. KARRERA K-FRAME — Installation & Service Manual...
  • Page 207: Section 6 - External Interfaces

    Introduction The Karrera K-Frame Video Production Center has that name because it is more than just a video switcher. For example, a Karrera K-Frame system is also able to control a variety of external devices. Devices can be associated with sources, via source definition. Three types of source definitions for the Karrera K-Frame are available: •...
  • Page 208: General External Device Interfacing

    Section 6 — External Interfaces General External Device Interfacing In general, interfacing an external device to the Karrera K-Frame system involves the following elements: • Control cabling and configuration (Ethernet, serial ports, GPIs). • Video cabling (K-Frame input connectors). • Creating an External Device Definition (for DDR, VTR, etc.) and assigning it to a source definition.
  • Page 209 None – Serial port settings are selected with these buttons. The Baud Rate / Parity button returns the settings to the Karrera K-Frame factory Set Default defaults. – Touching this button opens an alphanumeric keypad used to PBus Name give the PBus device a descriptive name.
  • Page 210 3. Highlight the PBus device you wish to copy the trigger names to. 4. Touch the button. Copy Names Once configured, PBus devices will be available to operators for use with EMEMs via the Devices, PBus menu. Figure 145. Devices, PBUS Menu KARRERA K-FRAME — Installation & Service Manual...
  • Page 211: Gpi Outputs

    Devices, GPI Outputs and PBus & GPI Enables menus, to help the operator identify each function. Duration – Sets the duration the relay will be closed, in video frames. – Touching this button triggers the selected GPI. Test GPI KARRERA K-FRAME — Installation & Service Manual...
  • Page 212 Section 6 — External Interfaces Once configured, GPI Outputs will be available to operators for use with EMEMs on the Devices GPI Outputs menu. Figure 147. Devices, GPI Outputs Menu KARRERA K-FRAME — Installation & Service Manual...
  • Page 213: Pbus And Gpi Enables

    PBus and GPI Output triggers will be inactive when the EMEM or Macro is run. Figure 148. PBus and GPI Enables Menu, PBus Tab Figure 149. PBus and GPI Enables Menu, GPI Tab KARRERA K-FRAME — Installation & Service Manual...
  • Page 214: External Devices

    The Eng Setup External Devices menus are used to create and edit Device Definitions. Different menus are displayed depending on whether a serial or Ethernet control type of device is selected. Figure 150. External Devices Menu, Serial Control Device KARRERA K-FRAME — Installation & Service Manual...
  • Page 215: Vdcp Ethernet

    Ports & Devices Figure 151. External Devices Menu, Ethernet Device VDCP Ethernet When VDCP Ethernet is selected, additional parameters are available. Figure 152. External Devices Menu, with VDCP Ethernet Selected KARRERA K-FRAME — Installation & Service Manual...
  • Page 216: Device Definition

    8007. Device Definition The Karrera K-Frame system uses a software External Device Definition object to define the capabilities of each device interfaced with the system. External Device Definitions contain the interface information required for that external device, (e.g., IP Address or Serial Port).
  • Page 217: Creating An External Device Definition

    4. Choose the control protocol for that device from the list. Type • If an Ethernet protocol was selected, enter the IP address for the External Device. • If a serial protocol was selected, choose the port the device will use. KARRERA K-FRAME — Installation & Service Manual...
  • Page 218: Tally Ports

    See the documentation that came with your tally system for more information. Additionally, tally is supported via GPO connections. Note Serial tally is not supported for K-Frame systems due to the vast amount of data being transmitted. KARRERA K-FRAME — Installation & Service Manual...
  • Page 219: Connecting Ethernet Tally

    2. In either port 1 or port 2, select the IP Address data pad. 3. Enter the client IP Address in the pop-up keypad and select Enter See the separate Grass Valley Switcher Protocols Manual for technical infor- mation. KARRERA K-FRAME — Installation & Service Manual...
  • Page 220: Editor Ports

    – Clears the selected serial port’s assignment. Unassign Editor – Serial port settings are selected with these buttons. The Baud Rate / Parity button returns the settings to the Karrera K-Frame factory Set Default defaults. KARRERA K-FRAME — Installation & Service Manual...
  • Page 221: Router Interface

    (router output). Changing the router source sends a different signal to the destination (called a take). A router destination can in turn be con- nected to a Karrera K-Frame input and be configured as a routed source (called switcher source in this discussion and in the GV Switcher menus).
  • Page 222: Router Source Name Changes (At The Router) And Gv Switcher Updates

    • Karrera K-Frame system configuration of routed Karrera K-Frame- sources. • Names of router sources are shown on the Karrera K-Frame Control Panel and Karrera K-Frame Menu Panel displays. • Router source selection control via the Karrera K-Frame Control Panel and Karrera K-Frame Menu Panel displays.
  • Page 223: Router Interface Installation

    Video Interface Cabling Connect each external routing system destination to an available input con- nector on the Karrera K-Frame Video Processor. You will need to know the input connector number used for each destination when you configure the Karrera K-Frame source.
  • Page 224: Primary And Secondary Router Communications

    30 seconds using the entered router IP addresses. Primary and Secondary Router Communications The Karrera K-Frame system will initially use the primary router IP address for communications. If the primary control system fails to respond, the system will attempt to use the secondary IP address for router commu-...
  • Page 225: Defining Routed Sources Definition

    4. If the routed source will have an associated key signal, touch the appropriate Key Input button, then touch the Key Input data pad and enter the number of the input that will be used with the router key signal destination. KARRERA K-FRAME — Installation & Service Manual...
  • Page 226: User Setups

    User Setups Once a Karrera K-Frame routed source has been defined, it can be mapped to source buttons using the standard button mapping procedure (User Prefs), and can be given alternate names (Suite Prefs, Source Patch menu).
  • Page 227 Router Interface KARRERA K-FRAME — Installation & Service Manual...
  • Page 228 Section 6 — External Interfaces KARRERA K-FRAME — Installation & Service Manual...
  • Page 229: Section 7 - Maintenance

    15 at the front of this manual. Grass Valley Web Site The URL for the Grass Valley web site can be found on page 4. Visit the website for documentation, software updates, online support (including FAQs), spare parts information, and a link to the File Transfer Protocol (FTP) site.
  • Page 230: Reset Procedures

    Figure 161. Karrera IP Address Mode Selection, EMEM Area Menu Menu Menu 1 Menu 2 Panel Stripe Trans Panel Macro Calib Time Date Delg Rate Addr Saver Bank Pause Pause Bank Pause Pause 3 /7 3/ 7 KARRERA K-FRAME — Installation & Service Manual...
  • Page 231: Software Installation

    Updates to GV Switcher system software are available for down- load from the Grass Valley website. Software installation tools are provided with each update package. Refer to the separate Karrera K-Frame Release Notes for complete software installation instructions. Software Option Authorization...
  • Page 232: Authorization Codes

    Authorization Codes The authorization process involves receiving an authorization code from Grass Valley and entering it in a menu on the system. The authorization code is associated with a particular Karrera K-Frame Video Processor, iden- tified by a System ID#, and is not transferable to different hardware. If you have multiple systems at your facility, you will need to enter an authoriza- tion code onto each system.
  • Page 233: Enter Permanent Authorization Code

    3. If you have more than one system, repeat the above steps on every system that will have options enabled. 4. Contact Grass Valley Customer Support and request a code for each Karrera K-Frame System ID. If options have not already been purchased, you can order the options directly from the service representative.
  • Page 234: Temporary Authorizations

    For demonstration or rental, optional features can be authorized tempo- rarily. Once you have obtained the temporary authorization code, enter it on the Karrera K-Frame system using the procedure described above, except you first select one of the buttons. Temporary authorization Temp information is displayed on the right portion of the menu.
  • Page 235 Move the Lever Arm down all the way and select (press Next Key Prior b. Move the Lever Arm up all the way and select (press Next Key Prior This saves the calibration values and exits calibration mode. KARRERA K-FRAME — Installation & Service Manual...
  • Page 236: Joystick Calibration

    (Figure 164 on page 235, left). 2. Select (press ) to enter calibration mode (Figure 164 on page 235, Calib right). 3. Choose the to calibrate (press (Figure 167). Joystick KARRERA K-FRAME — Installation & Service Manual...
  • Page 237 Move the Joystick to the top left corner, rotate it counter-clockwise and press b. Move the Joystick to the bottom right corner, rotate it clockwise and press c. Allow the Joystick to return to its center, unrotated position and press KARRERA K-FRAME — Installation & Service Manual...
  • Page 238: Panel Saver Time Adjustment

    The illuminated button indicates the current setting. Figure 171. Panel Saver Mode, EMEM Area Panel Saver Bank 3/ 7 KARRERA K-FRAME — Installation & Service Manual...
  • Page 239: Control Panel Webpages

    Control Panel in the hierarchy screen. After the Control Panel resets, restoring User and Panel Prefs and Panel Memory configuration files should restore the Control Panel to its previous operational state. KARRERA K-FRAME — Installation & Service Manual...
  • Page 240: Control Panel Ip Information

    The Reset button should only be used if the panel is in a state that does not allow an EMEM area reset. KARRERA K-FRAME — Installation & Service Manual...
  • Page 241 System Area (2) & Transition Master EMEM Transition & Local EMEM Multi-Function Source Sel 10 w/o Device Control (4) Input Cooling Fan (2) Distribution Controller & Board Distribution Power Board Supplies (2) Air Exhaust KARRERA K-FRAME — Installation & Service Manual...
  • Page 242 Area 3 Area 4 Area 5 Stripe Stripe Stripe A5 (option) STRIPE C STRIPE B STRIPE A (option) CAUTION Karrera panel data cables must be connected to the correct boards for proper system operation. KARRERA K-FRAME — Installation & Service Manual...
  • Page 243: 2-Me Control Panel Interior

    Figure 177. Karrera 2-ME Panel Open, Air Guide In Place Torsion Bar Lid Spring (2) Air Guide Cover Board Communications RJ45, but not Ethernet (8 of 10 used) Board Power Compact Reset USB (2) (4 of 8 used) Flash Button Power On/Off KARRERA K-FRAME — Installation & Service Manual...
  • Page 244 Source Sel 15 w/o System Area Transition & DSK Local EMEM & Transition Master EMEM Source Sel 10 w/o Device Multi-Function Control Input Cooling Controller & Distribution Power Board Supplies (2) Air Exhaust KARRERA K-FRAME — Installation & Service Manual...
  • Page 245 Area 5 Stripe Stripe Power Jumper POWER Between Boards (2) GROUP 2 GROUP 1 Note All power ports supply identical power. Power cable routing and jumpers shown are as shipped from the factory. KARRERA K-FRAME — Installation & Service Manual...
  • Page 246: General Control Panel Lid Switch Board Remove And Replace

    Suite, and User configuration data, and also has data for all the effects reg- isters. This data is stored as files on the Video Processor Frame CF card, and is loaded on bootup. Errors in this data could cause system problems, KARRERA K-FRAME — Installation & Service Manual...
  • Page 247: Clear Nv Ram For Control Panel And Frame

    2. Touch the button. Clear NV Figure 181. K-Frame Installer Program Clear NV 3. Click on the button. The following Clear NV Files screen will Clear NV appear. KARRERA K-FRAME — Installation & Service Manual...
  • Page 248: Restore System Files

    NV Memory will be cleared and the Menu or Frame will be rebooted. Restore System Files If you have a Show File with a set of standard Karrera K-Frame system set- tings, you can load it now to restore your system to that state. However, if you are experiencing problems, you may want to reload the files individu- ally to help find what might be causing problems.
  • Page 249: Ip Address Information

    The dipswitch is located Normal below the SATA drive on the control processor board, as shown in Figure 183. Figure 183. K-Frame Control Processor Board - S2 Boot Mode Dipswitch Location KARRERA K-FRAME — Installation & Service Manual...
  • Page 250: Lifetime Of The Internal Battery

    3. Remove the old battery by lifting the clip holding it in place. Figure 184. Video Processor Frame Controller Board with Battery Indicated 4. Put the new battery in place and secure the clip. 5. Re-insert the frame controller board and close the frame door. KARRERA K-FRAME — Installation & Service Manual...
  • Page 251: Touchscreen Calibration

    Touchscreen Calibration Touchscreen Calibration The Karrera K-Frame Touch Screen Menu Panel is adjusted in the factory before shipment, and so should not require calibration. If the Menu Panel does not respond correctly to screen touches, however, you can perform this procedure.
  • Page 252 4. Touch on the lower part of the screen (Figure 186). Configure Figure 187. Calibration Type Selection 5. Touch and then . You will return to the Calibration 4 Point Calibration menu screen. KARRERA K-FRAME — Installation & Service Manual...
  • Page 253 , and then . When done the TOUCH HOLD RELEASE application will register the location and move the circle to another corner. Repeat for all four corners. A blank screen will then appear (Figure 190). KARRERA K-FRAME — Installation & Service Manual...
  • Page 254: Diagnostics

    Capture Software Diagnostic Data Software diagnostic data can be captured on a K-Frame Video Processor. This information can be useful to Grass Valley engineers for trouble- shooting purposes. Typically this procedure is only used when the system is experiencing problems, and is done after a Video Processor Frame reboot.
  • Page 255: Control Panel Module Diagnostics

    3. After the files have been copied, the entire contents of the directory should be compressed into a .zip archive. Grass Valley Customer Support can provide instructions on how to send this information to the GV engineering team for analysis.
  • Page 256: Creating Compact Flash Cards

    The K-Frame Switcher Installer program is used to format, partition, and load boot files onto system CF cards. Once prepared in this manner, the appropriate GV Switcher software (Control Panel) will need to be installed KARRERA K-FRAME — Installation & Service Manual...
  • Page 257: Materials Required

    Kayenne Panel Karrera Panel A DOS window will start, and then a separate window opens asking for the CF card location (D, E, F etc.) with the memory size of the device. KARRERA K-FRAME — Installation & Service Manual...
  • Page 258 5. Click . A new Ghost application screen appears that reports the progress of the formatting. The process can take 8 to 20 minutes to fully erase, format, test and partition the CF card. KARRERA K-FRAME — Installation & Service Manual...
  • Page 259: Updating System Software On A New Control Panel Cf Card

    Updating System Software on a New Control Panel CF Card 1. Remove the CF card from the reader, power down the Control Panel, install the CF card in the Control Panel’s processor, and power up the panel. KARRERA K-FRAME — Installation & Service Manual...
  • Page 260: Restore Control Panel Configuration Files

    You will also need to enter the Node Settings information. Go to Eng Setup , and enter the IP address and device name information in the Nodes Settings tabs. Control Surfaces Frame Suite Nodes & ID KARRERA K-FRAME — Installation & Service Manual...
  • Page 261: Snmp Monitoring

    SNMP is an optional feature for Grass Valley switchers, and requires the purchase and entry of a license key. SNMP is an industry standard, however, any third party NMS can be used.
  • Page 262: Grass Valley Switcher Device Monitoring By Snmp

    Section 7 — Maintenance The Grass Valley switcher MIBs are available from Grass Valley Customer Support. Load the MIBs for the Video Processor Frame and Control Panel as shown in Table Table 20. Grass Valley Proprietary MIBs Description Video Processor Frame...
  • Page 263: Video Processor Frame

    Menu Panel Processor The Menu Panel Processor (the PC running the Menu application) can be monitored separately, using the standard built-in Windows SNMP capabil- ities and a third-party NMS. No unique Grass Valley MIB entries or traps are available. SNMP Installation Grass Valley K-Frame switchers system devices have SNMP Agent soft- ware already installed.
  • Page 264: Snmp Licensing

    Section 7 — Maintenance SNMP Licensing Grass Valley switcher system SNMP licensing is based on the Video Pro- cessor Frame, and is tied to that Frame’s unique System ID number. All Control Panels associated with a Frame will use that same SNMP license.
  • Page 265: Snmp Power Up License Processing

    Configuration steps consist of: • Enable/Disable SNMP • Configure Trap Destination IP addresses • Configure Community Name Configuration of the NMS software itself will also be required to make full use of the SNMP feature. KARRERA K-FRAME — Installation & Service Manual...
  • Page 266: Switcher Device Snmp Configuration Procedure

    Up to three IPs can be entered. 3. If you are not using the community, enter the name of the public community to be used. 4. Click Save New Settings KARRERA K-FRAME — Installation & Service Manual...
  • Page 267: Snmp Trap Messages

    The SNMP trap messages listed below are available for various switcher system components. Note Only the capabilities described in this document are supported. For detailed information about each supported item, please refer to the MIBs. KARRERA K-FRAME — Installation & Service Manual...
  • Page 268: Video Processor Frame Traps

    When the switcher starts the boot process and initializing = warning the trap status is “initializing” a trap is sent. running = normal Another trap is sent when the switcher becomes fully operational and the trap status is “running”. KARRERA K-FRAME — Installation & Service Manual...
  • Page 269: Control Panel Traps

    SNMP Monitoring Control Panel Traps Table 24. Supported Kayenne/Karrera K-Frame Control Panel Traps Name Type Description Severity gcpUnknown(1) Panel Status Change The panel is in an unknown state, or does not possess enough normal intelligence to report its state. NOTE: This value can be a bit-...
  • Page 270 Section 7 — Maintenance KARRERA K-FRAME — Installation & Service Manual...
  • Page 271: Specifications

    -20 to 70 deg C (-4 to 158 deg F) Operating temperature 0 to 40 deg C (32 to 104 deg F) Relative humidity 0-95% (non-condensing) Electromagnetic environment E2 (according to EN55103-1, -2) KARRERA K-FRAME — Installation & Service Manual...
  • Page 272: Appendix A — Specifications

    Standard 13 RU Up to 4 Up to 5 input Up to 4 output boards Up to 8 modules M/E boards boards (32 inputs (16 dual outputs per per input board) output board) KARRERA K-FRAME — Installation & Service Manual...
  • Page 273 Table 33. Analog Reference Input Video Standard Tri-level Sync or Color Black, analog equivalent to the standard being used. Return loss > 40dB, up to 5 MHz Connectors 2 BNC loop-through Impedance 75 ohm external KARRERA K-FRAME — Installation & Service Manual...
  • Page 274 100V-240V AC, 1.7A Line frequency 50/60Hz Power consumption Power brick output 12V, 5.0A Optional Local Aux Panel (35 or 25, powered from Karrera Panel) Power input 12V DC, 0.8A max Power consumption < 10W KARRERA K-FRAME — Installation & Service Manual...
  • Page 275 Appendix Field Replaceable Units This appendix provides lists of the Field Replaceable Units (FRU) and Crit- ical Spares for the Karrera K-Frame Video Production Center. FRUs can be ordered from Grass Valley Customer Support. Note The lists given here are for general guidelines only and are subject to change at any time.
  • Page 276: Appendix B — Field Replaceable Units

    751040900 Power Supply AC/DC 720007100 12VDSC 400W 33.3 A Power Supply Cable Assembly 731028800 Cable assembly for 720007100 power supply. Cable Assembly Power Supply Controller 731028200 Fuse 159504000 8A 250V 5X20mm IEC 60127-2/5 KARRERA K-FRAME — Installation & Service Manual...
  • Page 277 Table 36. FRU List and Replacement Notes and References - (continued) Name Part Number Replacement Notes and References Compact Flash Card 157050000 Blank KARRERA K-FRAME — Installation & Service Manual...
  • Page 278 KEYCAP BLANK E-SWITCH 15mm 260509300 SWITCH PB 12MM WELL-BUYING Spare Parts Kit 260509400 SWITCH PB 15MM WELL-BUYING 146013800 BATTERY COIN TYPE 3V,1000ma l-Ion 85567300 ROTARY OPTICAL ENCODER W/PUSH SWITCH 390714200 GV ENCODER KNOB KARRERA K-FRAME — Installation & Service Manual...
  • Page 279: Index

    Multiviewer Standard Frame button mapping Aux bus alternate names router interface router interface Button Mapping menu alternative name ambient temperature maximum Analog sync button cabling articulated arm ClipStore DAs assembly with Menu Panel KARRERA K-FRAME — Installation & Service Manual...
  • Page 280 ClipStore Config menu components Closedown Menu Computer button for resource sharing collaborative resource sharing Karrera K-Frame system command processing control surface configuration Compact Flash, see CF Card KARRERA K-FRAME — Installation & Service Manual...
  • Page 281 Control Panel module Ethernet communication Digital sync button Ethernet router dimensions Ethernet switch articulated arm for Menu Panel built in Menu Panel Video Processor Frame Direct button Ethernet Tally device definition KARRERA K-FRAME — Installation & Service Manual...
  • Page 282 History pane fixed source format conversion connectors Frame identity cooling Menu 178, power iDPM power supply default crop weight distribution Image Store Frame Operating Mode changing IP address Frame status independent resource sharing KARRERA K-FRAME — Installation & Service Manual...
  • Page 283 PC rear screw hole dimensions multiple tabletop bracket Karrera system name Local Aux 25 K-Frame dimensions Compact Video Processor Local Aux 35 Controller board connections dimensions Power Supply Frame installation Local Aux Panel KARRERA K-FRAME — Installation & Service Manual...
  • Page 284 Mac cabling connecting to existing Menu C:\ isolated menu category selection network cabling Menu identity network communications temporary 178, background information menu name network settings Menu on User PC KARRERA K-FRAME — Installation & Service Manual...
  • Page 285 Control Panel node copying trigger names Menu Panel node serial bus Remote Aux Panel node PBus and GPI Enables menu Relay Assign menu PBus Name button relay closure control PBus Ports menu Remote Aux Panel KARRERA K-FRAME — Installation & Service Manual...
  • Page 286 Router Destination Selection menu SetDef MatchDef menu router interface alternate names SetDef output conversion button mapping SetDef Timing button features setting with installer program general description setting with web page installation SNMP primary IP address configuration KARRERA K-FRAME — Installation & Service Manual...
  • Page 287 175, source patch feature system timing Source Patch menu timing analyzer specifications SystemA Standard Video Processor default system name cooling diagram dimensions front dimensions top front view door removed take rack mounting diagram KARRERA K-FRAME — Installation & Service Manual...
  • Page 288 SNMP traps tri-level sync Video Processor Frame name Video Settings menu video timing maximum switcher delay Unassign Editor button minimum switcher delay Unassign Ext. Device button nominal switcher delay KARRERA K-FRAME — Installation & Service Manual...
  • Page 289 Index virtual machine VM (virtual machine) VMWare warning Class A web browser access Control Panel weight distribution Frame KARRERA K-FRAME — Installation & Service Manual...
  • Page 290 Index KARRERA K-FRAME — Installation & Service Manual...

Table of Contents