Maintenance Schedule - Lennox Elite EDV35RNM Care And Operation Instructions Manual

Edv direct-vent gas fireplaces
Hide thumbs Also See for Elite EDV35RNM:
Table of Contents

Advertisement

MAINTENANCE SCHEDULE

Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
Annually (Before the onset of the Burning Season)
MAINTENANCE TASK
Inspect/Clean Burner, Logs
and Controls
Check Flame Patterns and Flame Height
Inspect/Clean Pilot and Burner
Check Vent System
Appliance Checkout
Replace Glowing Embers
Periodically (After the Burning Season)
MAINTENANCE TASK
Clean Firebox Interior
Check Flame Patterns and Flame Height
Check Vent System
Clean Front Glass Enclosure Panel
22
ACCOMPLISHING PERSON
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Service
Technician
ACCOMPLISHING PERSON
Homeowner
Homeowner
Homeowner
Homeowner
PROCEDURE
Inspect valve and ensure it is properly operating. Check piping for
leaks. Vacuum the control compartment, fireplace logs and burner area.
Refer to Figures 9 (EDV35), 10 (EDV40) or 11 (EDV45) on Page 15 and
verify the flame pattern and height displayed by the appliance conforms
to the picture. Flames must not impinge on the logs. Ensure flames
are steady (not lifting or floating).
Refer to Figure 13 (Millivolt) or Figure 14 (Electronic) on Page 16.
Remove any surface build-up on pilot and burner assembly. Wipe the
pilot nozzles, igniter/flame rod and hood. Ensure the pilot flame engulfs
the flame sensor as shown.
Inspect the vent system at the top and at the base (within the firebox) for
signs of blockage or obstruction.
deterioration of the vent components
NOTE: Excessive condensation can cause corrosion of caps, pipe & fit-
tings (excessive condensation can be caused by long lateral runs, too
many elbows, and/or exterior portions of the system being exposed to
cold weather). Also, inspect the wall straps or plumbers's tape to ensure
they are securely in place.
Perform the appropriate appliance checkout procedure detailed in this
manual.
Remove old
glowing ember
materials and vacuum the
area. Place new
embers per instructions on Page 12.
PROCEDURE
Carefully remove logs, glowing embers and volcanic stone. Vacuum
out interior of the firebox. Clean firebox walls and log grate. Replace
logs, glowing embers and volcanic stone as detailed in this manual.
Refer to Refer to Figures 9 (EDV35), 10 (EDV40) or 11 (EDV45) on Page
15 and verify the flame pattern and height displayed by the appliance
conforms to the picture. Flames must not impinge on the logs.
Inspect the vent system at the top and at the base (within the firebox)
for signs of blockage or obstruction. Look for any signs of dislocation
of the vent components
(reconnect or replace as
Clean as necessary following the directions provided in this manual. DO
NOT TOUCH OR ATTEMPT TO CLEAN GLASS WHILE HOT.
Look for any signs of dislocation or
(reconnect or replace as necessary).
ember
placement
necessary).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents