Maintenance Schedule - Lennox Dave Signature Montebello LSM45EN-PV Care And Operation Instructions Manual

Power vent dv gas fireplaces
Table of Contents

Advertisement

LENNOX HEARTH PRODUCTS • MONTEBELLO

MAINTENANCE SCHEDULE

Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
Annually (Before the onset of the Burning Season)
MAINTENANCE TASK
Inspect/Clean Burner, Logs
and Controls
Check Flame Patterns and Flame Height
Inspect/Clean Pilot and Burner
Check Vent System
Appliance Checkout
Replace Glowing Embers
Periodically (After the Burning Season)
MAINTENANCE TASK
Clean Firebox Interior
Check Flame Patterns and Flame Height
Check Vent System
Clean Front Glass Enclosure Panel
POWER VENT DV GAS FIREPLACES (LSM40/45EN-PV) • CARE AND OPERATION INSTRUCTIONS
®
ACCOMPLISHING PERSON
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Service
Technician
ACCOMPLISHING PERSON
Homeowner
Homeowner
Homeowner
Homeowner
PROCEDURE
Inspect valve and ensure it is properly operating. Check piping for
leaks. Vacuum the control compartment, fireplace logs and burner area.
Refer to Figures 13 and 14 on Page 12 and verify the flame pattern and
height displayed by the appliance conforms to the picture. Flames must
not impinge on the logs. Ensure flames are steady (not lifting or floating).
Refer to Figure 16 on Page 13. Remove any surface build-up on pilot
and burner assembly. Wipe the pilot nozzles, igniter/flame rod and hood.
Ensure the pilot flame engulfs the flame sensor as shown.
Inspect the vent system at the top and at the base (within the firebox)
for signs of blockage or obstruction. Look for any signs of dislocation
or deterioration of the vent components. Note: Excessive condensation
can cause corrosion of caps, pipe & fittings (excessive condensation can
be caused by long lateral runs, too many elbows and/or exterior portions
of the system being exposed to cold weather). Also inspect wall straps
or plumbers's tape to ensure it is secure and in place.
Perform the appropriate appliance checkout procedure detailed in this
manual.
Remove old ember materials (rockwool) and vacuum the ember place-
ment area. Place new embers per instructions on Page 10.
PROCEDURE
Carefully remove logs, rockwool and volcanic stone. Vacuum out interior
of the firebox. Clean firebox walls and log grate. Replace logs, rockwool
and volcanic stone as detailed in this manual.
Refer to Figures 13 and 14 on Page 12 and verify the flame pattern and
height displayed by the appliance conforms to the picture. Flames must
not impinge on the logs.
Inspect the vent system at the top and at the base (within the firebox)
for signs of blockage or obstruction. Look for any signs of dislocation
of the vent components.
Clean as necessary following the directions provided in this manual. DO
NOT TOUCH OR ATTEMPT TO CLEAN GLASS WHILE HOT.