Burner Flame Adjustments

WARNING
• Air shutter adjustment should
only be performed by a quali-
fied professional service tech-
nician.
• Ensure front glass panel are
in place and sealed during
adjustment.
CAUTION
• Soot will be produced if the
air shutter is closed too much.
Any damage due to sooting,
resulting from improperly
setting the air shutter, is not
covered under the warranty.
• The air shutter door and
nearby appliance surfaces
are hot. Exercise caution to
avoid injury while adjusting
flame appearance.
1. Refer to Figures 9, 10 and 11 for proper
flame appearance. To adjust the flame, rotate
the adjustment rod toward the back or toward
the front of the fireplace (rod located in the
lower control area). Position the air shutter
to the factory setting as shown in the table
in Figure 12.
2. Light appliance (follow lighting procedure
on lighting label in control compartment or
see the Pages 23 through 26).
3. Allow the burner to operate for at least 15
minutes while observing the flame continu-
ously to ensure that the proper flame ap-
pearance has been achieved. If the following
conditions are present, adjust accordingly.
• If flame appears weak or sooty, adjust
the air shutter, incrementally, to a more
open position until the proper flame
appearance is achieved.
• If flame remains blue, adjust the air
shutter, incrementally, to a more closed
position until the proper flame appear-
ance is achieved.
4. Leave the control knob (off/pilot/on) in the
ON position and the burner OFF/ON switch
OFF (and remote switches, if applicable).
5. When satisfied that the burner flame appear-
ance is normal, re-install the lower control
compartment door then proceed to finish
the installation.
16
Burner
Venturi
Tube
Air Shutter
Opening
Decrease
Increase
Air Shutter
Air Shutter
Opening
Opening
Air Shutter
Adjusting
Arm
Main Burner
Factory Shutter Opening Setting
Natural Gas
Models
inches (mm)
EDV35
EDV40
1/8 (3.2)
EDV45
Figure 12

Millivolt Appliance Checkout

The pilot flame should be steady, not lifting
or floating. Flame should be blue in color with
traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator
(thermopile) and the top 1/8" minimum (tip)
of the quick drop out thermocouple should be
engulfed in the pilot flame.
The flame should project 1" (25 mm) beyond
the hood at all three ports (see Figure 13).
Replace logs if removed for pilot inspection.
To light the burner; turn "ON" the remote wall
switch and rotate the gas valve control knob
counterclockwise to the "ON" position ("ON"
will be at the top side of the valve).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
MILLIVOLT
Thermocouple
Air
Shutter
Door
Pilot
Nozzels
Orifice
Figure 13 - Millivolt Pilot

Electronic Appliance Checkout

To light the burner, turn 'ON' the wall or remote
control switch. Ensure the igniter lights the pilot.
The pilot flame should engulf the flame rod as
shown in Figure 14.
Propane Gas
inches (mm)
3/8 (9.5)
Flame Rod
Flame Rod
(Sensor)
(sensor)
Figure 14 - Electronic Pilot
Hood
Igniter Rod
3/8" Min
(9 mm)
Thermopile
Igniter
Igniter
Pilot
Hood
Pilot Hood