Burner Flame Adjustments; Appliance Checkout - Lennox LSS-35CN Care And Operation Instructions Manual

Spectra series direct vent
Table of Contents

Advertisement

Burner Air Shutter Adjustment Procedure
WARNINGS
• Air shutter adjustment should
only be performed by a quali-
fied professional service
technician.
• Ensure front glass panel are
in place and sealed during
adjustment.
CAUTIONS
• Carbon will be produced if the
air shutter is closed too much.
Any damage due to carboning
resulting from improperly
setting the air shutter is not
covered under the warranty.
• The air shutter door and nearby
appliance surfaces are hot.
Exercise caution to avoid
injury while adjusting flame
appearance.
18
1. Locate adjustment lever and adjust air shutter
to the standard setting as shown in Figure
16 (adjustment rod is located in the lower
control compartment).
Note: Pushing the adjustment lever back to
decrease air and pulling forward to increase
air.
2. Light appliance (follow lighting procedure
on lighting label in control compartment or
see the lighting instructions, Page 22 in
this manual).
3. Allow the burner to operate for at least 15 min-
utes while observing the flame continuously
to ensure that the proper flame appearance
has been achieved (see Figures 14 or 15 on
Page 17). If the following conditions are
present, adjust accordingly.
• If flame appears weak or sooty, adjust the
air shutter, incrementally, to a more open
position until the proper flame appearance
is achieved.
• If flame stays lowered blue, adjust the air
shutter, incrementally, to a more closed
position until the proper flame appearance
is achieved.
4. Leave the control knob (off/pilot/on) in the
ON position and the burner OFF/ON switch
OFF (and remote switches, if applicable).
5. When satisfied that the burner flame ap-
pearance is normal, close the lower control
compartment door (see Figures 14 or 15 on
Page 17).

Appliance Checkout

The pilot flame should be steady, not lifting
or floating. Flame should be blue in color with
traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator (ther-
mopile) should be engulfed in the pilot flame.
The flame should project 1" (25 mm) beyond
the hood at both ports (see Figure 17).
To light the burner, refer to the lighting instruc-
tions on Page 22.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Burner
Venturi
Tube
Air Shutter
Opening
Orifice
Air Shutter
Adjusting
Rod
F
A
C
T
O
S
H
U
T
E T
R
G
s a
M
o
e d
s l
y T
e p
O
P
E
n i
h c
s e
N
. t a
1
2 /
1 (
L
S
- S
5 3
P
o r
. p
5
8 /
1 (
N
. t a
1
2 /
1 (
L
S
- S
0 4
P
o r
. p
5
8 /
1 (
Figure 16
Ignitor
Pilot
Hood
Sensor
Figure 17
Air Shutter
Arm
R
Y
A
R I
S
E
T T
N I
G
N
N I
G
(
m
m
)
. 3
) 0
. 5
) 8
. 3
) 0
. 5
) 8

Advertisement

Table of Contents
loading

Table of Contents