c
o
m
m
u
n
Zone Alarm
The panel will transmit the Zone Alarm Reporting Code when a zone goes into alarm. 24 hour type zones will
go into alarm whether the panel is armed or disarmed and report to the central station. All other types of zones
will only go into alarm if the panel is armed.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Zone Alarm Reporting Codes ........................................................ Section [320]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Zone Restoral
If the Restoral on Bell Time-out option is selected, the panel will send the Zone Restoral Reporting Code for
the zone if the bell cut-off time has expired and the zone is secured. If the zone is not secured when the alarm
output times out, the panel will send the restoral immediately once the zone is secured.
If the Restoral on Bell Time-out option is not selected, the panel will immediately send the Zone Restoral
Reporting Code when the zone is secured, regardless of whether or not the alarm output is active.
24 Hour type zones will report the restoral immediately once the zone is secured.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Zone Restoral Reporting Codes .................................................... Section [324]
Restoral on Bell Time-out ............................................. Section [380], Option [2]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Closings (Arming Codes)
The panel will transmit a Closing Reporting Code to indicate that the system is armed. A different Reporting
Code can be transmitted for each User Code and Master Code to identify who has armed the system.
A Special Closing Reporting Code will be transmitted if the system is armed using any of the following
methods:
• Quick Arming
• Arming via wireless key
If programmed, a Partial Closing Reporting Code will be sent along with the closing reporting code if one or
more zones were manually bypassed when the system was armed to warn the monitoring station of a security
compromise.
If the Closing Confirmation option is enabled, the control unit will sound a series of eight beeps to confirm to
the user that the closing code was sent and received by the central station.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Closing (Arming) Reporting Codes ...................................... Section [339]-[342]
Special Closing Reporting Code .................................................... Section [343]
Partial Closing Reporting Code ..................................................... Section [343]
Closing Confirmation .................................................... Section [381], Option [4]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Openings (Disarming Codes)
The panel will transmit an Opening Reporting Code to indicate that the system has been disarmed. A different
Reporting Code can be transmitted for each User Code and the Master Code to identify who has disarmed the
system.
A Special Opening reporting code will be transmitted if the system is disarmed using any of the following
methods:
• Disarming via keyswitch
If an alarm occurred while the system was armed, an Opening After Alarm
with an opening reporting code when the user disarms the system.
If Transmission Delay is being used, the Opening After Alarm code must be programmed. See
Section 6.5 "Transmission Delay."
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Opening (Disarming) Reporting Codes ............................... Section [344]-[348]
Opening After Alarm ....................................................................... Section [328]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Tampers
The panel will report a Zone Tamper Alarm Reporting Code if an open condition is present on any zone. A
different Reporting Code can be programmed to identify each zone. The Zone Tamper Restoral Reporting
Code will be transmitted immediately when the tamper condition is restored.
i
c
a
t
i
o
n
s
p
r
o
Opening After Alarm reporting code will be sent along
Opening After Alarm
Opening After Alarm
Opening After Alarm