Prime And Flush Storage Fluid - AIRLESSCO SL1100 Operation And Repair Manual

Airless 3000 psi (20.7mpa, 207 bar) maximum working pressure
Table of Contents

Advertisement

Operation
Fill the Packing Nut/Wet Cup
1. Fill the Packing Nut/Wet Cup with 5 drops of Air-
lessco Throat Seal Oil (TSO).
Flush the Sprayer
1. Flush the sprayer. See Flushing Procedure on
page 8.

Prime and Flush Storage Fluid

NOTICE
The equipment was tested with lightweight oil,
which is left in the fluid passages to protect parts.
To avoid contaminating your fluid with oil, flush the
equipment with a compatible solvent before using
the equipment for the first time.
Before beginning a new spraying project you need to
prime the sprayer and flush the storage fluid out of the
sprayer.
Oil- or Water-based Materials
When changing from water-based material to oil
based material, flush with soapy water and then
mineral spirits.
When changing from oil based material to water
base material, flush with mineral spirits, followed by
soapy water, then a clean water flush.
When flushing with solvents, ground pail and gun.
Flush before changing colors, before fluid can dry in
the equipment, at the end of the day, before storing,
and before repairing equipment.
8
Flushing
ti16049a
1. Make sure the gun trigger lock in engaged and there
2. Pour enough clean, compatible solvent into a large,
3. Place the suction tube into the pail or place the pail
4. Turn Pressure Control Knob to low.
5. Open the prime valve to the open - "Priming Posi-
6. Turn the engine ON/OFF switch to ON.
• To reduce the risk of static sparking, which can
cause fire or explosion, always hold a metal part of
the gun firmly against the metal pail when flushing.
This also reduces splashing.
• Always remove the spray tip before flushing.
is no spray tip in the gun. Refer to the separate
instruction manual provided with gun for safety fea-
tures and how to engage the trigger lock.
empty metal pail to fill the pump and hoses.
under the pump.
ti16048a
tion". This will allow an easy start.
Closed
(Pressure)
ti14790a
ti16028a
High Pressure
Open
(Priming and Pressure Relief)
ti14791a
3A1184A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents